High impedance leads and safety margin. Electrical considerations based on a simplified expression of the 'paradigm'.

For physicians who are not familiar with the electrical basis of cardiac stimulation, high impedance leads previously (10 years ago) considered as bad electrodes (high voltage) are now considered as the 'epitome' of lead technology (low energy drain): clearly impedance is not a good parameter for characterizing the qualities of a pacing lead. Using a simplified approach to the electrostimulation 'paradigm', it is easy to establish that modern high impedance leads are in fact high current density leads and high efficiency leads (better description). It is also possible to establish that routine programming of the safety margin at 100% above threshold parameters is associated with a decrease in the penetration of the electric field according to the reduction of the cathode surface area. For safety and energy saving, a small tip electrode could be combined with a low polarization surface treatment and a reduction in fibrosis development between electrode and myocardium.

Electric Impedance↗

Comparison of permanent left ventricular and biventricular pacing in patients with heart failure and chronic atrial fibrillation: prospective haemodynamic study.

OBJECTIVE: To compare clinical and haemodynamic variables between left ventricular and biventricular pacing in patients with severe heart failure; and to analyse haemodynamic changes during daily life and maximum exercise during chronic left ventricular and biventricular pacing. DESIGN: Prospective single blinded randomised study with crossover. SETTING: University hospital (tertiary referral centre). PATIENTS AND METHODS: 13 patients (mean (SD) age, 62 (6) years) with chronic atrial fibrillation, severe heart failure (mean ejection fraction 24 (8)%), and QRS prolongation of > or = 140 ms had His bundle ablation and installation of a pacemaker providing left ventricular and biventricular pacing. The pacemaker was equipped with a peak endocardial acceleration (PEA) sensor. The PEA pattern was used as a haemodynamic marker during exercise as it is highly correlated with left ventricular dP/dt. After a baseline period of right ventricular pacing, all patients had two months of left ventricular pacing and two months of biventricular pacing in random order. At the end of each phase, an echocardiogram, a haemodynamic analysis at rest and on exercise during a six minute walk test, and a cardiopulmonary exercise test were performed. RESULTS: PEA values were higher with left ventricular pacing (0.58 (0.38) m/s) and biventricular pacing (0.62 (0.24) m/s) than at baseline (0.49 (0.18) m/s) (p < 0.05). The six minute walk test showed similar performance in both pacing modes, but patients had more symptoms with left ventricular pacing at the end of the test (p = 0.035). On cardiopulmonary exercise testing, there was a greater increase in mean percentage variation of PEA with biventricular pacing than with left ventricular pacing (125 (18)% v 97 (36)%, respectively; p = 0.048) and better performance figures (92 (34) W v 77 (23) W; p = 0.03). CONCLUSIONS: During symptom limited and daily life exercise tests, chronic biventricular pacing provides better haemodynamic performance than left ventricular pacing. In heart failure patients with wide QRS complexes, the interventricular dyssynchronisation induced by left ventricular pacing may impair myocardial function during exercise.

Adult↗

[Role of radiofrequency ablation in atrial fibrillation].

Atrial fibrillation is the most frequently encountered arrhythmia in the human species. Its danger is widely appreciated but it remains for certain patients and their practitioners an awkward or even exasperating problem. Only surgery and radiofrequency ablation allow certain patients to be cured. The surgical approach is of course warranted in the case of an otherwise necessary cardiac intervention. In the absence of a surgical indication, endovenous ablation, which is less aggressive, is preferred. The procedure consists of disconnecting the pulmonary veins which "house" 80 to 95% of the foci, together with the ablation of further non-venous foci, which are always difficult to treat. Side effects in experimental centres are rare and 70% of patients are cured, which allows cessation of antiarrhythmic and anticoagulant treatments. The procedure is currently offered to symptomatic patients having had at least one episode every ten days in spite of antiarrhythmics.

Anti-Arrhythmia Agents↗

Morphological characteristics of P waves during selective pulmonary vein pacing.

OBJECTIVES: We sought to assess the value of 12-lead electrocardiogram (ECG) P-wave morphology to recognize the paced pulmonary vein (PV). BACKGROUND: Prediction of arrhythmogenic PVs producing ectopy or initiating atrial fibrillation (AF) using 12-lead ECG may facilitate curative ablation. METHODS: In 30 patients P-wave configurations were studied during sinus rhythm and during pacing at six sites from the four PVs: top and bottom of each superior PV and both inferior PVs. The P-wave amplitude, duration and morphology were assessed, and predictive accuracies were calculated for the most significant parameters. An algorithm predicting the paced PV was developed and prospectively evaluated in a different population of 20 patients. RESULTS; Three criteria were used to distinguish right from left PV: 1) a positive P-wave in lead aVL and the amplitude of P-wave in lead I > or =50 microV indicated right PV origin (specificity 100% and 97%, respectively); 2) a notched P-wave in lead II was a predictor of left PV origin (specificity 95%); and 3) the amplitude ratio of lead III/II and the duration of positivity in lead V(1) were also helpful in distinguishing left versus right PV origin. In addition, superior PVs could be distinguished from inferior according to the amplitude in lead II (> or =100 microV). In prospective evaluation, an algorithm based on the above four criteria identified 93% of left versus right PV and totally 79% of the specific PVs paced. CONCLUSIONS: Pacing from the different PVs produced a P-wave with distinctive characteristics that could be used as criteria in an algorithm to identify the PV of origin with an accuracy of 79%.

Aged↗

Comparison of chronic biventricular pacing between epicardial and endocardial left ventricular stimulation using Doppler tissue imaging in patients with heart failure.

In patients with a wide QRS, drug-resistant heart failure, and a coronary sinus that is unsuitable for transvenous biventricular pacing (BVP), a transseptal approach from the right to left atrium can allow endocardial left ventricular (LV) pacing (with permanent anticoagulant therapy) instead of epicardial pacing via the coronary sinus branches. We sought to compare the effects of endocardial pacing with those of epicardial LV pacing on regional LV electromechanical delay (EMD) and contractility. Twenty-three patients (68 +/- 8 years) with severe heart failure and QRS > or =130 ms received a pacemaker for BVP. Fifteen patients underwent epicardial LV pacing, and 8 underwent endocardial LV pacing because of an unsuitable coronary sinus. All LV leads were placed at the anterolateral LV wall. Six months after implant, echocardiography and Doppler tissue imaging were performed. LV wall velocities and regional EMDs (time interval between the onset of the QRS and local ventricular systolic motion) were calculated for the 4 LV walls and compared for each patient between right ventricular (RV) and BVP. The amplitude of regional LV contractility was also assessed. Epicardial BVP reduced the septal wall EMD by 11% versus RV pacing (p = 0.05) and the lateral wall EMD by 41% versus RV pacing (p <0.01). With endocardial BVP, the septal and lateral EMDs were 21.3% and 54%, respectively (p <0.01, compared with epicardial BVP). The mitral time-velocity integral increased by 40% with endocardial BVP versus 2% with epicardial BVP (p <0.01). The amplitude of the lateral LV wall systolic motion increased by 14% with epicardial BVP versus 31% with endocardial BVP (p = 0.01). This resulted in a LV shortening fraction increase of 25% in patients with endocardial BVP (p = 0.05). However, all patients were clinically improved at the end of follow-up. Thus, in heart failure patients with BVP, endocardial BVP provides more homogenous intraventricular resynchronization than epicardial BVP and is associated with better LV filling and systolic performance.

Aged↗

Transvenous left atrial and left ventricular pacing in Ebstein's anomaly with severe interatrial conduction block.

The implantation of permanent pacemakers in patients with congenital heart disease can be challenging. This report describes the complexity of pacemaker implantation in a patient with Ebstein's disease, tricuspid valve replacement, and right atrial abnormalities like severe intra- and interatrial conduction block that prevented dual chamber pacing from conventional sites. This case illustrates the promising possibility to circumvent the interatrial conduction block with single left atrial pacing instead of biatrial pacing which was not suitable here.

Cardiac Pacing, Artificial↗

Validation by serial standardized testing of a new rate-responsive pacemaker sensor based on variations in myocardial contractility.

AIMS: Preliminary studies have shown that peak endocardial acceleration (PEA), measured by a micro-accelerometer at the right ventricular apex, is highly correlated with left ventricular contractility (dp/dt max). Furthermore, changes in PEA are closely correlated with sinus node rate changes during exercise and during pharmacological interventions. Peak endocardial acceleration has, therefore, been used to drive a rate-responsive DDD pacemaker. This study compared the chronotropic performance of such devices implanted in 14 patients suffering from chronotropic incompetence with that observed in 18 control subjects in normal sinus rhythm. METHODS AND RESULTS: Five standardized daily life activities (hall walk, climbing up and down stairs, squatting and hyperventilation) and two types of exercise (Bruce treadmill protocol and bicycle ergometry) were performed in a random order after individual programming of each pacemaker. For each test, a correlation coefficient was calculated between changes in PEA and variations in paced rate, between instantaneous variations in heart rate monitored by telemetry and continuous measurement of heart rate by the pacemaker, and between sensor-driven rate in patients and normal sinus rhythm in controls. The variations in paced heart rate were closely correlated with those observed in subjects with normal sinus rhythm, and proved to be sensitive, specific, rapid and independent of the type of exercise. After optimal programming of the sensor, PEA modulates the heart rate as expected during normal sinus rhythm. CONCLUSIONS: In this study, a single PEA sensor successfully restored chronotropic response in a population of paced patients with severe chronotropic incompetence. Peak endocardial acceleration can be monitored on a beat-to-beat basis, in parallel with heart rate, and the pacemaker can be accurately programmed with a single exercise test.

Aged↗

[Genetics of prostate cancer].

Genetic epidemiology studies have suggested the responsibility of genetic factors in prostate cancer susceptibility. The development of genomic and high throughput genetic studies has allowed the recent identification or localization of such susceptibility genes. Furthermore, these technologies have contributed to outstanding advances in somatic genetics of prostate cancer. The goal of the present review is to disclose contributing technologies to and results of genetic studies of prostate cancer.

Chromosome Aberrations↗

[Ablation of atrial fibrillation: where are we now?].

Atrial fibrillation is the commonest arrhythmia. Besides the risk of complications, a significant number of patients remain symptomatic despite the different anti-arrhythmic drugs currently available. The only curative treatment is by surgery or catheter ablation. Since 1994, several approaches have been developed based on two main concepts: modification of the arrhythmogenic substrate by linear lesion to prevent the perpetuation of the arrhythmia and ablation of the foci initiating the atrial fibrillation. The later approach is the most popular one at the moment because the concentration of foci at the site of the pulmonary veins makes it possible to isolate them relatively easily. The presence of atrial foci in some patients complicates matters and limits the success rate to 70%. Despite these limitations and with an acceptable rate of complications, this approach appears preferable to His bundle ablation in young patients with symptomatic paroxysmal atrial fibrillation resistant to antiarrhythmic therapy.

Adult↗

Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation.

BACKGROUND: Radiofrequency catheter ablation of accessory pathways (APs) is very effective in all but a minority of patients. We examined the usefulness and safety of irrigated-tip catheters in treating patients with APs resistant to conventional catheter ablation. METHODS AND RESULTS: Among 314 APs in 301 consecutive patients, conventional ablation failed to eliminate AP conduction in 18 APs in 18 patients (5.7%), 6 of which were located in the left free wall, 5 in the middle/posterior-septal space, and 7 inside the coronary sinus (CS) or its tributaries. Irrigated-tip catheter ablation was subsequently performed with temperature control mode (target temperature, 50 degrees C), a moderate saline flow rate (17 mL/min), and a power limit of 50 W (outside CS) or 20 to 30 W (inside CS) at previously resistant sites. Seventeen of the 18 resistant APs (94%) were successfully ablated with a median of 3 applications using irrigated-tip catheters. A significant increase in power delivery was achieved (20.3+/-11.5 versus 36.5+/-8.2 W; P:<0.01) with irrigated-tip catheters, irrespective of the AP location, particularly inside the CS or its tributaries. No serious complications occurred. CONCLUSIONS: Irrigated-tip catheter ablation is safe and effective in eliminating AP conduction resistant to conventional catheters, irrespective of the location.

Adult↗

Electrophysiological breakthroughs from the left atrium to the pulmonary veins.

BACKGROUND: The extent of ostial ablation necessary to electrically disconnect the pulmonary vein (PV) myocardial extensions that initiate atrial fibrillation from the left atrium has not been determined. METHODS AND RESULTS: Seventy patients underwent PV mapping with a circumferential 10-electrode catheter during sinus rhythm or left atrial pacing. After assessment of perimetric distribution and activation sequence of PV potentials, ostial ablation was performed at segments showing earliest activation, with the end point of PV disconnection. A total of 162 PVs (excluding right inferior PVs) were ablated. PV potentials were present at 60% to 88% of their perimeter, but PV muscle activation was always sequential from a segment with earliest activation (breakthrough). Radiofrequency (RF) application at this breakthrough eliminated all PV potentials in 34 PVs, whereas a secondary breakthrough required RF applications at separate segments in 77; in others, >2 segments were ablated. A median of 5, 6, and 4 bipoles from the circular catheter were targeted in the right superior, left superior, and inferior PVs, respectively, to achieve PV disconnection. Early recurrence of arrhythmia was observed in 31 patients as a result of new venous or atrial foci or recovery of previously targeted PVs, most related to a single recovered breakthrough that was reablated with local RF application. CONCLUSIONS: Although PV muscle covers a large extent of the PV perimeter, there are specific breakthroughs from the left atrium that allow ostial PV disconnection by use of partial perimetric ablation.

Angiography↗

Mapping-guided ablation of pulmonary veins to cure atrial fibrillation.

Catheter ablation of triggers inducing paroxysms of atrial fibrillation (AF) is an emerging therapy for this common arrhythmia. In a series of 225 consecutive patients with AF resistant to multiple drugs, 96% presented with triggering foci originating from 1 or multiple pulmonary veins (PV), independently of whether or not the patient had ectopy or structural heart disease. The present article describes the mapping and ablation techniques applicable to individual patients: (1) criteria to define an arrhythmogenic PV; (2) use of provocative maneuvers; and (3) the role of circumferential mapping catheters to provide extent, distribution, and activation of PV muscle as well as monitoring distal PV potentials (PVP) during ablation. Radiofrequency ablation can be performed by targeting the PVP during sinus rhythm (right PV) or left atrial pacing (left PV) with the procedural endpoint of PVP elimination, which is more effective in predicting a successful outcome than suppression of acute ectopy. Complete elimination of AF is presently obtained in 70% of patients, allowing interruption of arrhythmias and in use anticoagulants. It is anticipated that continued technologic improvements will improve and facilitate this technique of curative treatment of AF.

Atrial Fibrillation↗

Differential pacing for distinguishing block from persistent conduction through an ablation line.

BACKGROUND: Because complete linear conduction block is necessary to minimize the recurrence of reentrant tachycardias such as typical atrial flutter, we investigated a simple technique to recognize a persistent gap or complete linear block. METHODS AND RESULTS: We prospectively evaluated cavotricuspid isthmus conduction in 50 patients (age 63+/-8 years, 43 men) after radiofrequency ablation. The distal and proximal bipoles of a quadripolar catheter placed close to the ablation line were successively stimulated during recording from the ablation line. We hypothesized that because the initial and terminal components of local potentials reflected activation at the ipsilateral and contralateral borders of the ablation lesion, a change to a more proximal pacing site without moving the catheter would prolong the stimulus to the initial component timing, whereas the response of the terminal component would depend on the presence of block or persistent conduction. A shortening or no change in timing of the terminal component would indicate block, whereas lengthening would indicate persistent gap conduction. The results were compared with previously described criteria for isthmus block. Ninety-two sites were assessed: 17 before and 75 after the achievement of complete isthmus block. The timing of the initial component was delayed by 19+/-9 ms, and the terminal component was advanced by 13+/-8 ms after block and delayed by 12+/-9 ms in case of persisting conduction. The sensitivity, specificity, and positive and negative predictive values for linear block were 100%, 75%, 94%, and 100%, respectively. CONCLUSIONS: An accurate assessment of isthmus block or persistent isthmus conduction is possible with this technique of differential pacing.

Aged↗