PubMed Health⌕ Search

Biomedical subjects

P Jaïs

Publications and source records attributed to P Jaïs.

At least 37 records · Page 2Linked to original sources

Validation by serial standardized testing of a new rate-responsive pacemaker sensor based on variations in myocardial contractility.

AIMS: Preliminary studies have shown that peak endocardial acceleration (PEA), measured by a micro-accelerometer at the right ventricular apex, is highly correlated with left ventricular contractility (dp/dt max). Furthermore, changes in PEA are closely correlated with sinus node rate changes during exercise and during pharmacological interventions. Peak endocardial acceleration has, therefore, been used to drive a rate-responsive DDD pacemaker. This study compared the chronotropic performance of such devices implanted in 14 patients suffering from chronotropic incompetence with that observed in 18 control subjects in normal sinus rhythm. METHODS AND RESULTS: Five standardized daily life activities (hall walk, climbing up and down stairs, squatting and hyperventilation) and two types of exercise (Bruce treadmill protocol and bicycle ergometry) were performed in a random order after individual programming of each pacemaker. For each test, a correlation coefficient was calculated between changes in PEA and variations in paced rate, between instantaneous variations in heart rate monitored by telemetry and continuous measurement of heart rate by the pacemaker, and between sensor-driven rate in patients and normal sinus rhythm in controls. The variations in paced heart rate were closely correlated with those observed in subjects with normal sinus rhythm, and proved to be sensitive, specific, rapid and independent of the type of exercise. After optimal programming of the sensor, PEA modulates the heart rate as expected during normal sinus rhythm. CONCLUSIONS: In this study, a single PEA sensor successfully restored chronotropic response in a population of paced patients with severe chronotropic incompetence. Peak endocardial acceleration can be monitored on a beat-to-beat basis, in parallel with heart rate, and the pacemaker can be accurately programmed with a single exercise test.

Aged↗

[Genetics of prostate cancer].

Genetic epidemiology studies have suggested the responsibility of genetic factors in prostate cancer susceptibility. The development of genomic and high throughput genetic studies has allowed the recent identification or localization of such susceptibility genes. Furthermore, these technologies have contributed to outstanding advances in somatic genetics of prostate cancer. The goal of the present review is to disclose contributing technologies to and results of genetic studies of prostate cancer.

Chromosome Aberrations↗

[Ablation of atrial fibrillation: where are we now?].

Atrial fibrillation is the commonest arrhythmia. Besides the risk of complications, a significant number of patients remain symptomatic despite the different anti-arrhythmic drugs currently available. The only curative treatment is by surgery or catheter ablation. Since 1994, several approaches have been developed based on two main concepts: modification of the arrhythmogenic substrate by linear lesion to prevent the perpetuation of the arrhythmia and ablation of the foci initiating the atrial fibrillation. The later approach is the most popular one at the moment because the concentration of foci at the site of the pulmonary veins makes it possible to isolate them relatively easily. The presence of atrial foci in some patients complicates matters and limits the success rate to 70%. Despite these limitations and with an acceptable rate of complications, this approach appears preferable to His bundle ablation in young patients with symptomatic paroxysmal atrial fibrillation resistant to antiarrhythmic therapy.

Adult↗

Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation.

BACKGROUND: Radiofrequency catheter ablation of accessory pathways (APs) is very effective in all but a minority of patients. We examined the usefulness and safety of irrigated-tip catheters in treating patients with APs resistant to conventional catheter ablation. METHODS AND RESULTS: Among 314 APs in 301 consecutive patients, conventional ablation failed to eliminate AP conduction in 18 APs in 18 patients (5.7%), 6 of which were located in the left free wall, 5 in the middle/posterior-septal space, and 7 inside the coronary sinus (CS) or its tributaries. Irrigated-tip catheter ablation was subsequently performed with temperature control mode (target temperature, 50 degrees C), a moderate saline flow rate (17 mL/min), and a power limit of 50 W (outside CS) or 20 to 30 W (inside CS) at previously resistant sites. Seventeen of the 18 resistant APs (94%) were successfully ablated with a median of 3 applications using irrigated-tip catheters. A significant increase in power delivery was achieved (20.3+/-11.5 versus 36.5+/-8.2 W; P:<0.01) with irrigated-tip catheters, irrespective of the AP location, particularly inside the CS or its tributaries. No serious complications occurred. CONCLUSIONS: Irrigated-tip catheter ablation is safe and effective in eliminating AP conduction resistant to conventional catheters, irrespective of the location.

Adult↗

Electrophysiological breakthroughs from the left atrium to the pulmonary veins.

BACKGROUND: The extent of ostial ablation necessary to electrically disconnect the pulmonary vein (PV) myocardial extensions that initiate atrial fibrillation from the left atrium has not been determined. METHODS AND RESULTS: Seventy patients underwent PV mapping with a circumferential 10-electrode catheter during sinus rhythm or left atrial pacing. After assessment of perimetric distribution and activation sequence of PV potentials, ostial ablation was performed at segments showing earliest activation, with the end point of PV disconnection. A total of 162 PVs (excluding right inferior PVs) were ablated. PV potentials were present at 60% to 88% of their perimeter, but PV muscle activation was always sequential from a segment with earliest activation (breakthrough). Radiofrequency (RF) application at this breakthrough eliminated all PV potentials in 34 PVs, whereas a secondary breakthrough required RF applications at separate segments in 77; in others, >2 segments were ablated. A median of 5, 6, and 4 bipoles from the circular catheter were targeted in the right superior, left superior, and inferior PVs, respectively, to achieve PV disconnection. Early recurrence of arrhythmia was observed in 31 patients as a result of new venous or atrial foci or recovery of previously targeted PVs, most related to a single recovered breakthrough that was reablated with local RF application. CONCLUSIONS: Although PV muscle covers a large extent of the PV perimeter, there are specific breakthroughs from the left atrium that allow ostial PV disconnection by use of partial perimetric ablation.

Angiography↗

Mapping-guided ablation of pulmonary veins to cure atrial fibrillation.

Catheter ablation of triggers inducing paroxysms of atrial fibrillation (AF) is an emerging therapy for this common arrhythmia. In a series of 225 consecutive patients with AF resistant to multiple drugs, 96% presented with triggering foci originating from 1 or multiple pulmonary veins (PV), independently of whether or not the patient had ectopy or structural heart disease. The present article describes the mapping and ablation techniques applicable to individual patients: (1) criteria to define an arrhythmogenic PV; (2) use of provocative maneuvers; and (3) the role of circumferential mapping catheters to provide extent, distribution, and activation of PV muscle as well as monitoring distal PV potentials (PVP) during ablation. Radiofrequency ablation can be performed by targeting the PVP during sinus rhythm (right PV) or left atrial pacing (left PV) with the procedural endpoint of PVP elimination, which is more effective in predicting a successful outcome than suppression of acute ectopy. Complete elimination of AF is presently obtained in 70% of patients, allowing interruption of arrhythmias and in use anticoagulants. It is anticipated that continued technologic improvements will improve and facilitate this technique of curative treatment of AF.

Atrial Fibrillation↗

Differential pacing for distinguishing block from persistent conduction through an ablation line.

BACKGROUND: Because complete linear conduction block is necessary to minimize the recurrence of reentrant tachycardias such as typical atrial flutter, we investigated a simple technique to recognize a persistent gap or complete linear block. METHODS AND RESULTS: We prospectively evaluated cavotricuspid isthmus conduction in 50 patients (age 63+/-8 years, 43 men) after radiofrequency ablation. The distal and proximal bipoles of a quadripolar catheter placed close to the ablation line were successively stimulated during recording from the ablation line. We hypothesized that because the initial and terminal components of local potentials reflected activation at the ipsilateral and contralateral borders of the ablation lesion, a change to a more proximal pacing site without moving the catheter would prolong the stimulus to the initial component timing, whereas the response of the terminal component would depend on the presence of block or persistent conduction. A shortening or no change in timing of the terminal component would indicate block, whereas lengthening would indicate persistent gap conduction. The results were compared with previously described criteria for isthmus block. Ninety-two sites were assessed: 17 before and 75 after the achievement of complete isthmus block. The timing of the initial component was delayed by 19+/-9 ms, and the terminal component was advanced by 13+/-8 ms after block and delayed by 12+/-9 ms in case of persisting conduction. The sensitivity, specificity, and positive and negative predictive values for linear block were 100%, 75%, 94%, and 100%, respectively. CONCLUSIONS: An accurate assessment of isthmus block or persistent isthmus conduction is possible with this technique of differential pacing.

Aged↗

Mapping and ablation of left atrial flutters.

BACKGROUND: Typical right atrial isthmus-dependent flutters have been described in detail, but very little is known about left atrial (LA) flutters. METHODS AND RESULTS: We performed conventional and 3D mapping of the LA for 22 patients with atypical flutters. Complete maps in 17 patients demonstrated macroreentrant circuits (n=15) with 1 to 3 loops rotating around the mitral annulus, the pulmonary veins, and a zone of block or a silent area. In 2 patients, a small reentry circuit with a zone of markedly slow conduction was identified. Linear ablation performed across the most accessible part of the circuit cured 16 patients (73%) with a follow-up of 15+/-7 months. CONCLUSIONS: LA reentrant tachycardias are related to individually varying circuits and are amenable to mapping guided radiofrequency ablation.

Adult↗

Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci.

BACKGROUND: The end point for catheter ablation of pulmonary vein (PV) foci initiating atrial fibrillation (AF) has not been determined. METHODS AND RESULTS: Ninety patients underwent mapping during spontaneous or induced ectopy and/or AF initiation. Ostial PV ablation was performed by use of angiograms to precisely define targeted sites. Success defined by elimination of AF without drugs was correlated with the procedural end point of the abolition of distal PV potentials. A total of 197 arrhythmogenic PV foci (97%)-single in 31% and multiple in 69%-and 6 atrial foci were identified. A discrete radiofrequency (RF) application eliminated the PV potentials in 9 PV foci, whereas 2 foci from the same PV required RF applications at separate sites in 19 cases. In others, a wider region was targeted with progressive elimination of ectopy. In 49 patients, multiple sessions were necessary owing to recurrent or new ectopy. The clinical success rates were 93%, 73%, and 55% in patients with 1, 2, and > or =3 arrhythmogenic PV foci. Recovery of local PV potential and the inability to abolish it were significantly associated with AF recurrences (90% success rate with versus 55% without PV potential abolition). PV stenosis was noted acutely in 5 of 6 cases, remained unchanged at restudy, and was associated with RF power >45 W. CONCLUSIONS: Multiple PV foci are involved in initiation of AF, and elimination of PV muscle conduction is associated with clinical success.

Adult↗

Prospective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter.

BACKGROUND: Radiofrequency (RF) ablation of common flutter requires the creation of a complete ablation line to produce bidirectional conduction block in the cavotricuspid isthmus. An irrigated-tip ablation catheter has been shown to be effective in patients in whom conventional ablation has failed. This randomized study compares the efficacy and safety of this catheter with those of a conventional catheter for de novo flutter ablation. METHODS AND RESULTS: Cavotricuspid ablation was performed with a conventional (n=26) or an irrigated-tip catheter (n=24). RF was applied for 60 minutes with a temperature-controlled mode: 65 degrees C to 70 degrees C up to 70 W with a conventional catheter or 50 degrees C up to 50 W (with a 17-mL/min saline flow rate) with the irrigated-tip catheter. The end point was the achievement of bidirectional isthmus block, and a crossover was performed after 21 unsuccessful applications. Procedural ablation parameters as well as number of applications, x-ray exposure, procedure duration, impedance rise, and clot formation were compared for each group. A coronary angiogram was performed before and after each ablation for the first 30 patients. Complete bidirectional isthmus block was achieved for all patients. Four patients crossed over from conventional to irrigated-tip catheters. The number of applications, procedure duration, and x-ray exposure were significantly higher with the conventional than with the irrigated-tip catheter: 13+/-10 versus 5+/-3 pulses, 53+/-41 versus 27+/-16 minutes, and 18+/-14 versus 9+/-6 minutes, respectively. No significant side effects occurred, and the coronary angiograms of the first 30 patients after ablation were unchanged. CONCLUSIONS: Irrigated-tip catheters were found to be more effective than and as safe as conventional catheters for flutter ablation, facilitating the rapid achievement of bidirectional isthmus block.

Aged↗

Dual-loop intra-atrial reentry in humans.

BACKGROUND: Dual-loop atrial reentrant tachycardias have not been clinically described. METHODS AND RESULTS: Five patients (3 men, 2 women; mean age, 48+/-16 years) were studied 24+/-15 years after surgical closure of an ostium secundum atrial septal defect for drug-resistant atrial tachycardia. Complete tachycardia mapping was performed in the right atrium with multipolar catheters and a 3-dimensional electroanatomic mapping system (Biosense), followed by linear radiofrequency ablation of the narrowest part of each complete loop. Six tachycardias with a typical flutter morphology, a cycle length of 262+/-40 ms, and a superior f-wave axis (-77+/-11 degrees ) were mapped, 4 with a Biosense map including 106+/-32 points. Five figure-8 tachycardias had a counterclockwise loop around the tricuspid valve sharing a common anterior channel with a clockwise loop around the lateral atriotomy scar. One tachycardia was thought to have 2 counterclockwise loops around the same obstacles. Radiofrequency delivery in the cavotricuspid isthmus in each case transformed the tachycardia without any pause in a different morphology tachycardia with an inferior P-wave axis (50+/-42 degrees ) and nearly the same cycle length (272+/-39 ms) but with the periatriotomy loop alone. This arrhythmia required ablation of a second isthmus: between the lower end of the atriotomy and the inferior vena cava in 4 and the superior tricuspid annulus in 1. After a follow-up of 19+/-6 months, there were no recurrences. CONCLUSIONS: Figure-8 double-loop tachycardias mimicking the ECG pattern of a common atrial flutter occur in some patients after a surgical atriotomy. Ablation of 1 loop produces a sudden transformation to a new reentrant tachycardia formed of the remaining loop that requires ablation at a second isthmus.

Adult↗

Tracking dynamic conduction recovery across the cavotricuspid isthmus.

OBJECTIVES: We sought to assess the dynamic temporal course of conduction recovery during and after radiofrequency (RF) catheter ablation of the cavotricuspid isthmus. BACKGROUND: Although cavotricuspid isthmus block is accepted as the best end point of ablation for typical flutter, conduction recovery is thought to underlie many eventual recurrences. Its time course and frequency have not been determined. METHODS: In a prospective group of 30 patients (26 men and 4 women, age 64 +/- 12 years) undergoing ablation of typical flutter in the cavotricuspid isthmus, the morphology of the P wave during pacing from the low lateral right atrium after achievement of complete isthmus block was identified as a reference. Regression of this morphologic P wave change was confirmed to be associated with intracardiac evidence of the recovery of cavotricuspid isthmus conduction and was observed throughout the procedure both during ablation in sinus rhythm (n = 15, group B) and just after flutter termination (n = 15, group A). RESULTS: Stable complete isthmus block was achieved in all patients; 29 had a terminal positivity of the paced P wave. Flutter termination resulted in stable block and terminal P wave positivity in three patients, transient terminal P wave positivity and transient block despite continuing RF at the same site in five patients and no block in the remaining seven patients. Conduction recovery identified by recovery of P wave changes was nearly as common (48%) during ablation in sinus rhythm. Multiple recoveries were noted in some patients, and 72% of all recoveries occurred within 1 min. Conduction recovery was only rarely associated with coagulum, impedance elevation or pops. CONCLUSIONS: Conduction recovery in the cavotricuspid isthmus is common during and after ablation and can be accurately, dynamically and continuously observed by monitoring the recovery of the low lateral right atrial paced P wave change.

Aged↗

Atrial fibrillation: role of arrhythmogenic foci.

UNLABELLED: Atrial fibrillation, the most common of all sustained cardiac arrhythmias can be cured by Surgical atriotomies or linear RF catheter ablation. We have investigated the role of focal RF ablation in paroxysmal atrial fibrillation. METHODS: sixteen patients with focal atrial fibrillation (extrasystoles, atrial tachycardia and atrial fibrillation due to the same focus firing irregularly at different rates) and 45 with common AF initiated by extrasystolic foci were included. The ablation site was determined on the basis of earliest bipolar activity relative to a stable atrial electrogram reference or to the P wave onset during atrial fibrillation initiation. RESULTS: All the patients with focal atrial fibrillation were treated with a mean of 5 +/- 4 RF applications delivered on a right atrial site (n = 4) or on a pulmonary venous site (n = 13), (one patient had 2 foci). Sixty nine foci (located in the pulmonary veins in 94%) were identified in the 45 patients with common atrial fibrillation initiated by extrasystoles. They were ablated with a mean of 4.5 +/- 2 RF applications. Using a mean follow up of 8 +/- 6 months, 28/45 (62%) were cured without antiarrhythmic drugs. CONCLUSION: Pulmonary veins play an important role in paroxysmal atrial fibrillation. They are the most frequent source of focal atrial fibrillation and of initiating foci amenable to RF ablation.

Adult↗

Intermediate-term results of biventricular pacing in heart failure: correlation between clinical and hemodynamic data.

Biventricular (BV) pacing acutely improves the hemodynamic status of patients with chronic heart failure (CHF) and wide QRS complex. Long-term data are few. This study examined the relationship between hemodynamic and clinical status of BV-paced CHF patients over an intermediate duration of follow-up. Forty-seven patients (mean age 64 +/- 11 years, 19% women, LVEF 0.23 +/- 0.07) with QRS > or = 140 ms received a DDD-BVP device for management of CHF due to ischemic disease in 21 (45%) patients. Clinical, electrocardiographic, exercise testing, and hemodynamic measurements were followed over an 8-month period. Seven patients died during the study, four patients suddenly. A significant decrease in NYHA class, from 3.3 +/- 0.6 before implantation, to 2.5 +/- 0.57 months after device implantation (P < 0.01) was measured, although 23% of patients reported no symptomatic improvement. Paced QRS narrowing by BVP was unchanged throughout follow-up (166 +/- 28 vs 159 +/- 23 ms, P = NS). Maximal VO2 values did not change (15.7 +/- 5 vs 16 +/- 8 mL/kg per min, P = NS). Echocardiographic parameters showed that the degree of mitral regurgitation was significantly decreased during BV pacing compared with no pacing (1.8 +/- 1.0 before implantation vs 1.3 +/- 0.7, P < 0.01). The radionuclide LVEF was not statistically different during no pacing, versus BV pacing at 3 months or 8 months after pacemaker implantation (24 +/- 9 vs 26 +/- 11 vs 25 +/- 10%, respectively, P = NS). Of nine patients whose QRS duration was prolonged by BV pacing, two were not hemodynamically and clinically improved at the end of follow-up. Patients not improved by BV pacing had the same degree of QRS shortening (203 +/- 39 vs 167 +/- 26 ms, P < 0.01) as patients who were clinically improved during follow-up (193 +/- 40 to 171 +/- 24 ms, P < 0.01). In multivariate analysis, ischemic heart disease (P = 0.025), absence of mitral regurgitation regression (P = 0.01), and older age (P = 0.04) predicted the absence of improvement by BV pacing. By standard noninvasive measures, intermediate-term BV pacing was associated with no objective hemodynamic improvement, though more than three fourths of the patients reported being clinically improved. A global improvement in left ventricular function by BV pacing may become apparent only over longer periods of observations. Patients with CHF unimproved by BV pacing are more likely to suffer from ischemic heart disease and less likely to have BV pacing induced regression of mitral regurgitation, regardless of changes in QRS duration.

Blood Flow Velocity↗

Hemodynamic assessment of right, left, and biventricular pacing by peak endocardial acceleration and echocardiography in patients with end-stage heart failure.

Multisite ventricular pacing acutely improves the hemodynamic status in heart failure, though longer-term observations require invasive procedures. The hemodynamics of multisite ventricular pacing were assessed by echocardiography and peak endocardial acceleration (PEA) measured by a pacemaker sensor. PEA variations are highly correlated with those of dP/dt. Thirteen end-stage heart failure patients (left ventricular ejection fraction < 0.30) with a QRS > or = 140 ms received a DDD PEA sensor-driven pacemaker allowing right (RV), left (LV) and biventricular (BV) pacing. Ten days after implantation, standard echocardiographic parameters and variations in PEA were measured after 20 minutes at each pacing mode. The aortic systolic preejection time interval was statistically comparable between RV and LV pacing (218 +/- 24 vs 219 +/- 34 ms; P = NS), and significantly shorter with BV pacing (198 +/- 27 ms; P = 0.013). Aortic ejection duration was nonsignificantly shorter during BV pacing than during LV pacing (-.061, P = 0.09). The aortic velocity time integer increased during LV pacing versus RV pacing (+21%, P < 0.05) and during BV pacing versus RV pacing (+37%, P = 0.05). As a result, the values of the PEA variations over a 15-minute period were significantly greater during LV pacing and BV pacing versus RV pacing (+43%, P < 0.05, and +38%, P = 0.05, respectively) and were statistically comparable between BV pacing and LV pacing (9% for LV pacing, P = NS). During various ventricular pacing configurations, PEA measurements were consistent with echocardiographic data, showing comparable hemodynamic effects of BV and LV pacing. The PEA sensor is a promising tool for long-term hemodynamic monitoring and serial evaluation of the effects of multisite ventricular pacing in heart failure patients.

Cardiac Pacing, Artificial↗

Mid-term follow-up of endocardial biventricular pacing.

Biventricular (BV) pacing is a promising treatment of end-stage heart failure. This article describes our experience with a strictly endocardial BV pacing system in patients with severe congestive heart failure. Three women and eight men (age 65 +/- 9 years) with drug-resistant end-stage CHF underwent implantation of an endocardial BV pacing system. In the first seven patients, the left ventricular lead was placed via a combined femoral and internal jugular approach. In the last four patients, the transseptal puncture was directly performed via the right internal jugular vein with a dedicated kit. The procedure was successful in all 11 patients. The acute left ventricular and BV thresholds were 1.3 +/- 0.6 V and 2.4 +/- 1 V, respectively. The QRS duration decreased from 214 +/- 57 to 176 +/- 25 ms. A functional improvement was noted in ten patients with a decrease in mean NYHA functional class from 3.7 +/- 0.5 before, to 2.6 +/- 0.9 after system implantation. A significant decrease in pulmonary capillary wedge pressure and increase in cardiac output were measured in eight patients. During follow-up, four patients died from CHF (n = 3) or ventricular fibrillation (n = 1). Under oral anticoagulation, no thromboembolic event was observed but one transient ischemic attack occurred in one patient whose anticoagulation was interrupted. Endocardial BV pacing is technically feasible and appears safe, though further studies are needed before it is used on a longer scale.

Aged↗