PubMed HealthSearch

Biomedical subjects

P K Hansma

Publications and source records attributed to P K Hansma.

16 recordsLinked to original sources

Atomic force microscopy of single- and double-stranded DNA.

A method has been developed for imaging single-stranded DNA with the atomic force microscope (AFM). phi X174 single-stranded DNA in formaldehyde on mica can be imaged in the AFM under propanol or butanol or in air. Measured lengths of most molecules are on the order of 1 mu, although occasionally more extended molecules with lengths of 1.7 to 1.9 mu are seen. Single-stranded DNA in the AFM generally appears lumpier than double-stranded DNA, even when extended. Images of double-stranded lambda DNA in the AFM show more sharp kinks and bends than are typically observed in the electron microscope. Dense, aggregated fields of double-stranded plasmids can be converted by gentle rinsing with hot water to well spread fields.

Bacteriophage lambda

Streptavidin binding observed with an atomic force microscope.

An atomic force microscope (AFM) was used to investigate a specific recognition reaction: the binding of streptavidin to a biotinylated lipid bilayer. Prior to the recognition reaction, the phase coexistence of the lipid bilayer was clearly observed: fluid domains were lower than the crystalline domains. After introducing to the bilayer a very dilute solution of streptavidin to give a final concentration of approximately 0.5 microM, the recognition reaction was imaged in real time. Several hours later, we observed a contrast reversal, i.e., the previously lower fluid domains grew so much in height that they became higher than the crystalline domains. We found that the streptavidin molecules bound almost exclusively to the biotin in the fluid domain (less than 0.25% coverage of the crystalline domains). The apparent structure of the few streptavidin molecules bound to the crystalline domain of the bilayer is shown to depend on the applied force. Finally, in a 2-dimensional quasi-crystal in which the streptavidin molecules were compressed at the air-water interface molecular resolution was achieved.

Bacterial Proteins

Investigation of dialysis membranes with atomic force microscopy.

AFM was used to investigate dialysis membranes made of regenerated cellulose by the cuoxam process. The membranes were either Cuprophan or experimental samples, modified with different amounts of diethylaminoethylcellulose (DEAE). Atomic force microscopes with optical-lever detection systems were used to image the dry membranes in air as received from the manufacturer as well as wet membranes in a swollen state under water. Differences could be observed between modified and unmodified as well as between dry and wet membranes.

Cellulose

Atomic force microscopy of uncoated plasmid DNA: nanometer resolution with only nanogram amounts of sample.

Reproducible, high-contrast, nanometer-resolution AFM images of uncoated plasmid DNA can be obtained with nanogram quantities of DNA with the help of two advances in sample preparation: (1) Heating a DNA solution at 35 degrees C for 10 to 20 minutes before deposition on mica helps separate and spread the DNA, and (2) Using 5 microliter drops of the heated DNA solution in the concentration range of 2 to 10 nanogram/microliter in contact with a specially prepared mica surface for 5 to 10 minutes gives optimal coverage with only nanograms of DNA.

Aluminum Silicates

Atomic force microscopy of hydrated phosphatidylethanolamine bilayers.

We present images of the polar or headgroup regions of bilayers of dimyristoyl-phosphatidylethanolamine (DMPE), deposited by Langmuir-Blodgett deposition onto mica substrates at high surface pressures and imaged under water at room temperature with the optical lever atomic force microscope. The lattice structure of DMPE is visualized with sufficient resolution that the location of individual headgroups can be determined. The forces are sufficiently small that the same area can be repeatedly imaged with a minimum of damage. The DMPE molecules in the bilayer appear to have relatively good long-range orientational order, but rather short-range and poor positional order. These results are in good agreement with x-ray measurements of unsupported lipid monolayers on the water surface, and with electron diffraction of adsorbed monolayers.

Biophysical Phenomena

Atomic force microscopy: seeing molecules of lipid and immunoglobulin.

The atomic force microscope (AFM) can image individual molecules by raster-scanning a sharp tip over a surface. In this paper we present molecular-resolution images of immunoglobulin M (IgM) and of ultraviolet light-polymerized films of the lipid dimethyl-bis(pentacosadiynoyloxyethyl) ammonium bromide ("BRONCO"). The polar head groups of individual lipid molecules can be resolved on the surface of this and other lipid films. These lipid films also provide a good substrate for AFM imaging of DNA and of other molecules such as antibodies. Because the AFM scans surfaces, it is most often successful at imaging either molecules that can form an array on a surface or molecules that are quite firmly attached to a surface. The ability of the AFM to operate under water, buffers, and other liquids makes it possible to study biological molecules under conditions in which they are physiologically active. Imaging of the actual molecular process of fibrin polymerization shows the potential of the AFM for studying biological processes. In the six years since its invention, the AFM has excited much interest and has imaged molecules in a wide range of systems.

Antibodies

Immobilized proteins in buffer imaged at molecular resolution by atomic force microscopy.

Samples of supported planar lipid-protein membranes and actin filaments on mica were imaged by atomic force microscopy (AFM). The samples were fully submerged in buffer at room temperature during imaging. Individual proteins bound to the reconstituted membrane were distinguishable; some structural details could be resolved. Also, surface-induced, self-assembling of actin filaments on mica could be observed. Monomeric subunits were imaged on individual actin filaments. The filaments could be manipulated on or removed from the surface by the tip of the AFM. The process of the decoupling of the filamentous network from the surface upon changing the ionic conditions was imaged in real time.

Actins

Imaging the membrane protein bacteriorhodopsin with the atomic force microscope.

The membrane protein bacteriorhodopsin was imaged in buffer solution at room temperature with the atomic force microscope. Three different substrates were used: mica, silanized glass and lipid bilayers. Single bacteriorhodopsin molecules could be imaged in purple membranes adsorbed to mica. A depression was observed between the bacteriorhodopsin molecules. The two dimensional Fourier transform showed the hexagonal lattice with a lattice constant of 6.21 +/- 0.20 nm which is in agreement with results of electron diffraction experiments. Spots at a resolution of approximately 1.1 nm could be resolved. A protein, cationic ferritin, could be imaged bound to the purple membranes on glass which was silanized with aminopropyltriethoxysilane. This opens the possibility of studying receptor/ligand binding under native conditions. In addition, purple membranes bound to a lipid bilayer were imaged. These images may help in interpreting results of functional studies done with purple membranes adsorbed to black lipid membranes.

Adsorption

Imaging single-stranded DNA, antigen-antibody reaction and polymerized Langmuir-Blodgett films with an atomic force microscope.

The combination of an (AFM) atomic force microscope together with microfabricated cantilevers that have integrated tips opens many possibilities for imaging systems of great importance in biology. We have imaged single-stranded 25mer DNA that was adsorbed on treated mica or that was covalently bound with a crosslinker to a polymerized Langmuir-Blodgett (LB) film, the top monolayer of a bilayer system. At low magnification the AFM shows cracks between solid domains, like in an image taken with a fluorescence microscope. At higher magnification, however, the AFM reveals much finer cracks and at still higher magnification it reveals rows of individual molecules in the polymerized LB film with a spacing of 0.45 nm. We have also imaged a LB film consisting of lipids in which 4% of the lipids had hapten molecules chemically bound to the lipid headgroups. Specific antibodies can then bind to these hapten molecules and be imaged with the AFM. This points to the possibility of using the AFM to monitor selective antibody binding.

Antibodies

Imaging crystals, polymers, and processes in water with the atomic force microscope.

The atomic force microscope (AFM) can be used to image the surface of both conductors and nonconductors even if they are covered with water or aqueous solutions. An AFM was used that combines microfabricated cantilevers with a previously described optical lever system to monitor deflection. Images of mica demonstrate that atomic resolution is possible on rigid materials, thus opening the possibility of atomic-scale corrosion experiments on nonconductors. Images of polyalanine, an amino acid polymer, show the potential of the AFM for revealing the structure of molecules important in biology and medicine. Finally, a series of ten images of the polymerization of fibrin, the basic component of blood clots, illustrate the potential of the AFM for revealing subtle details of biological processes as they occur in real time.

Crystallography

The scanning ion-conductance microscope.

A scanning ion-conductance microscope (SICM) has been developed that can image the topography of nonconducting surfaces that are covered with electrolytes. The probe of the SICM is an electrolyte-filled micropipette. The flow of ions through the opening of the pipette is blocked at short distances between the probe and the surface, thus, limiting the ion conductance. A feedback mechanism can be used to maintain a given conductance and in turn determine the distance to the surface. The SICM can also sample and image the local ion currents above the surfaces. To illustrate its potential for imaging ion currents through channels in membranes, a topographic image of a membrane filter with 0.80-micrometer pores and an image of the ion currents flowing through such pores are presented.

Cell Membrane

STM and AFM images of nucleosome DNA under water.

We have imaged DNA from the calf thymus nucleosome using a scanning tunneling microscope (STM) operated in water. The fragments are deposited onto the interface between a buffer solution and an epitaxially grown gold surface using an electrochemical tecnique. Most of the fragments are fairly straight, and when individual polymers can be identified, their length is consistent with the expected 146 basepairs (approximately 500 A). The resolution is often adequate to show signs of the 36 A helical pitch. Some images show a structure which appears to have abrupt kinks of the sort predicted by Crick and Klug (Nature 255, 530-533, 1975). In order to check that this shape is not a consequence of binding to underlying structure on the gold substrate, we have also made images of kinked structures using an atomic force microscope (AFM) with the DNA bound to glass.

Animals

Scanning tunneling microscopy and atomic force microscopy: application to biology and technology.

The scanning tunneling microscope (STM) and the atomic force microscope (AFM) are scanning probe microscopes capable of resolving surface detail down to the atomic level. The potential of these microscopes for revealing subtle details of structure is illustrated by atomic resolution images including graphite, an organic conductor, an insulating layered compound, and individual adsorbed oxygen atoms on a semiconductor. Application of the STM for imaging biological materials directly has been hampered by the poor electron conductivity of most biological samples. The use of thin conductive metal coatings and replicas has made it possible to image some biological samples, as indicated by recently obtained images of a recA-DNA complex, a phospholipid bilayer, and an enzyme crystal. The potential of the AFM, which does not require a conductive sample, is shown with molecular resolution images of a nonconducting organic monolayer and an amino acid crystal that reveals individual methyl groups on the ends of the amino acids. Applications of these new microscopes to technology are demonstrated with images of an optical disk stamper, a diffraction grating, a thin-film magnetic recording head, and a diamond cutting tool. The STM has even been used to improve the quality of diffraction gratings and magnetic recording heads.

Animals

Imaging cells with the atomic force microscope.

Different types of cells have been imaged with the atomic force microscope. The morphology of the archaebacterium Halobacterium halobium in its dry state was revealed. On a leaf of the small Indian tree Lagerstroemia subcostata a stoma was imaged. The lower side of a water lily leaf was imaged in water showing features down to 12 nm. Finally, fixed red and white blood cells were imaged in buffer showing features down to 8 nm. The images demonstrate that atomic force microscopy can provide high-resolution images of cell surfaces under physiological conditions.

Animals