Acetabular dysplasia in the adolescent and young adult.

Hip dysplasia is a major cause of osteoarthrosis in adults. Early aggressive osteotomy has the potential of preventing the development of arthritis, but carries with it significant risks. The problem is further complicated because the surgeon has no means of quantifying the dysplastic deformity or of predicting what a particular combination of osteotomies would do to correct the deformity. This study describes methods of quantifying hip-joint geometry in three dimensions based on computed tomography and magnetic resonance studies, and of simulating pelvic osteotomy to correct the deformities. The study analyzes 49 normal hip joints and 20 dysplastic hip joints. The results show that the normal acetabulum is nearly a full hemisphere, which is anteverted 20 degrees and abducted 53 degrees. The normal lateral center-edge angle is 37 degrees. The dysplastic acetabulum is not anterolaterally maldirected, as has been assumed, but is globally dysplastic. Analysis of the individual dysplastic hip joints showed a wide variability. Some patients were deficient globally, some anterolaterally, and some posterolaterally. Methods of analyzing a patient's hip joint, quantifying abnormalities, simulating surgery, and predicting results are demonstrated in a case example.

Acetabulum

Computer-controlled radiation therapy.

Radiation therapy is often hampered in important body regions by the need to transit sensitive normal tissues which act as dose-limiting barriers. Computer-controlled radiation therapy permits the simultaneous variation of multiple treatment parameters during irradiation of the patient, producing improved dose distributions with the potential for improved local control. Equipment used for this purpose includes a Mevatron XII linear accelerator, redesigned for automatic control, and a PDP 11/45 minicomputer. Dose distributions are shown and potential clinical gains discussed.

Computers

Correction for beam hardening in computed tomography.

Corrections for beam-hardening artifacts in computed tomography can be made by using a model which assumes that water and bone mineral are the only constituents of tissue. With this model, a correction factor for the measured transmission values can be calculated such that the reconstructed attenuation coefficients have values corresponding to a monoenergetic source of known energy. Systematic errors in the uncorrected attenuation coefficients, which may be 5%, can be reduced to less than 1% if corrected transmission values are used.

Body Water

Wedge-shaped dose distributions by computer-controlled collimator motion.

We have recently installed a linear accelerator, modified to allow computer control of several machine parameters during irradiation of the patient. As an initial feasibility study of computer-controlled radiation therapy, its application to produce wedge-shaped dose distributions by moving the collimator jaws has been evaluated. The required collimator motions have been calculated with an iterative technique. When these routines were used during irradiations of phantoms containing radiographic film, a good correspondence between calculated and measured dose distributions was observed. It is concluded that computer-controlled motion of the collimator jaws to shape the dose distribution is technically feasible. Additionally, this technique has the advantage that the wedge angle can be continuously adjusted and the isodose curves optimized for a particular depth and field size.

Computers