Computational flow study of the continuous flow ventricular assist device, prototype number 3 blood pump.

A computational fluid dynamics study of blood flow in the continuous flow ventricular assist device, Prototype No. 3 (CFVAD3), which consists of a 4 blade shrouded impeller fully supported in magnetic bearings, was performed. This study focused on the regions within the pump where return flow occurs to the pump inlet, and where potentially damaging shear stresses and flow stagnation might occur: the impeller blade passages and the narrow gap clearance regions between the impeller-rotor and pump housing. Two separate geometry models define the spacing between the pump housing and the impeller's hub and shroud, and a third geometry model defines the pump's impeller and curved blades. The flow fields in these regions were calculated for various operating conditions of the pump. Pump performance curves were calculated, which compare well with experimentally obtained data. For all pump operating conditions, the flow rates within the gap regions were predicted to be toward the inlet of the pump, thus recirculating a portion of the impeller flow. Two smaller gap clearance regions were numerically examined to reduce the recirculation and to improve pump efficiency. The computational and geometry models will be used in future studies of a smaller pump to determine increased pump efficiency and the risk of hemolysis due to shear stress, and to insure the washing of blood through the clearance regions to prevent thrombosis.

Computer Simulation↗

Motor feedback physiological control for a continuous flow ventricular assist device.

The response of a continuous flow magnetic bearing supported ventricular assist device, the CFVAD3 (CF3) to human physiologic pressure and flow needs is varied by adjustment of the motor speed. This paper discusses a model of the automatic feedback controller designed to develop the required pump performance. The major human circulatory, mechanical, and electrical systems were evaluated using experimental data from the CF3 and linearized models developed. An open-loop model of the human circulatory system was constructed with a human heart and a VAD included. A feedback loop was then closed to maintain a desired reference differential pressure across the system. A proportional-integral (PI) controller was developed to adjust the motor speed and maintain the system reference differential pressure when changes occur in the natural heart. The effects of natural heart pulsatility on the control system show that the reference blood differential pressure is maintained without requiring CF3 motor pulsatility.

Algorithms↗

Test controller design, implementation, and performance for a magnetic suspension continuous flow ventricular assist device.

A new continuous flow ventricular assist device using full magnetic suspension has been designed, constructed, and tested. The magnetic suspension centers the centrifugal pump impeller within the clearance passages in the pump, thus avoiding any form of contact. The noncontact operation is designed to give very high expected mechanical reliability, large clearances, low hemolysis, and a relatively small size compared to current pulsatile devices. A unique configuration of magnetic actuators on the inlet side and exit sides of the impeller provides full 5 axis control and suspension of the impeller. The bearing system is divided into segments which allow for 3 displacement axes and 2 angular control axes. The controller chosen for the first suspension tests consists of a decentralized set of 5 proportional integral derivative (PID) controllers. This document describes both the controller and an overview of some results pertaining to the magnetic bearing performance. The pump has been successfully operated in both water and blood under design conditions suitable for use as a ventricular assist device.

Equipment Design↗

Performance of a continuous flow ventricular assist device: magnetic bearing design, construction, and testing.

A new centrifugal continuous flow ventricular assist device, the CFVAD III, which is fully magnetic bearing suspended, has been developed. It has only one moving part (the impeller), has no contact (magnetic suspension), is compact, and has minimal heating. A centrifugal impeller of 2 inch outer diameter is driven by a permanent magnet brushless DC motor. This paper discusses the design, construction, testing, and performance of the magnetic bearings in the unit. The magnetic suspension consists of an inlet side magnetic bearing and an outlet side magnetic bearing, each divided into 8 pole segments to control axial and radial displacements as well as angular displacements. The magnetic actuators are composed of several different materials to minimize size and weight while having sufficient load capacity to support the forces on the impeller. Flux levels in the range of 0.1 T are employed in the magnetic bearings. Self sensing electronic circuits (without physical sensors) are employed to determine the impellar position and provide the feedback control signal needed for the magnetic bearing control loops. The sensors provide position sensitivity of approximately 0.025 mm. A decentralized 5 axis controller has been developed using modal control techniques. Proportional integral derivative controls are used for each axis to levitate the magnetically supported impeller.

Algorithms↗

Using hybrid magnetic bearings to completely suspend the impeller of a ventricular assist device.

Clinically available blood pumps and those under development suffer from poor mechanical reliability and poor biocompatibility related to anatomic fit, hemolysis, and thrombosis. To alleviate these problems concurrently in a long-term device is a substantial challenge. Based on testing the performance of a prototype, and on our judgment of desired characteristics, we have configured an innovative ventricular assist device, the CFVAD4, for long-term use. The design process and its outcome, the CFVAD4 system configuration, is described. To provide unprecedented reliability and biocompatibility, magnetic bearings completely suspend the rotating pump impeller. The CFVAD4 uses a combination of passive (permanent) and active (electric) magnetic bearings, a mixed flow impeller, and a slotless 3-phase brushless DC motor. These components are shaped, oriented, and integrated to provide a compact, implantable, pancake-shaped unit for placement in the left upper abdominal quadrant of adult humans.

Biocompatible Materials↗

Right-left ventricular balance in implanted electrically powered artificial hearts.

An electrohydraulic total artificial heart (EHTAH), using an interatrial shunt (IAS) for right-left heart balance, was evaluated in acute, in vivo, open-chested calves. The EHTAH system demonstrated physiologic autoregulation with Starling-like responsiveness to preload. Output varied from 4 to 9 L/min, as right atrial pressure increased from 3 to 15 mmHg. Device output was minimally influenced by afterload. The efficacy of an IAS to balance the EHTAH was demonstrated over a wide range of preload and afterload conditions. Interatrial shunt flow rates, reflective of the degree of right-left imbalance, varied from 2% to 14% (IAS flow from left to right) of cardiac output. Left atrial pressures typically did not exceed right atrial pressures by more than 6-8 mmHg using an instrumented vascular graft such as the IAS. The simplicity and distinct anatomic, surgical, and engineering advantages of the IAS approach to right-left balance of implanted electrically powered artificial hearts justify further development toward a reliable long-term design.

Animals↗

Magnetic suspension controls for a new continuous flow ventricular assist device.

A new continuous flow ventricular assist device (CFVAD III) using a full magnetic suspension has been constructed. The magnetic suspension centers the centrifugal impeller within the clearance passages in the pump, thus avoiding any contact. This noncontact operation gives very high expected mechanical reliability, large clearances, low hemolysis, low thrombosis, and relatively small size compared with current pulsatile devices. A unique configuration of a system of magnetic actuators on the inlet side and exit sides of the impeller gives full five axis control and suspension of the impeller. The bearing system is divided into segments that allow for three displacement axes and two angular control axes. For the first suspension tests, a decentralized set of proportional, derivative, and integral (PID) controllers acting along the modal coordinates are used to suspend the impeller. The controller design takes into account the blood forces acting on the magnetically suspended impeller, the unbalance forces on the impeller and gravitational loads during various body motions. In the final design, the bearing control axes will be coupled together through fluidic forces so the electronic feedback controller is a centralized multiple input, multiple output controller. The control system design must be robust against these types of externally imposed loads to keep the impeller centered and avoid blood damage. This article discusses the dynamic model, controller, and controller implementation for the magnetic suspension controller of CFVAD III.

Biomechanical Phenomena↗