PubMed Health⌕ Search

Biomedical subjects

P Matula

Publications and source records attributed to P Matula.

At least 19 recordsLinked to original sources

Precise 3D image alignment in micro-axial tomography.

Micro (micro-) axial tomography is a challenging technique in microscopy which improves quantitative imaging especially in cytogenetic applications by means of defined sample rotation under the microscope objective. The advantage of micro-axial tomography is an effective improvement of the precision of distance measurements between point-like objects. Under certain circumstances, the effective (3D) resolution can be improved by optimized acquisition depending on subsequent, multi-perspective image recording of the same objects followed by reconstruction methods. This requires, however, a very precise alignment of the tilted views. We present a novel feature-based image alignment method with a precision better than the full width at half maximum of the point spread function. The features are the positions (centres of gravity) of all fluorescent objects observed in the images (e.g. cell nuclei, fluorescent signals inside cell nuclei, fluorescent beads, etc.). Thus, real alignment precision depends on the localization precision of these objects. The method automatically determines the corresponding objects in subsequently tilted perspectives using a weighted bipartite graph. The optimum transformation function is computed in a least squares manner based on the coordinates of the centres of gravity of the matched objects. The theoretically feasible precision of the method was calculated using computer-generated data and confirmed by tests on real image series obtained from data sets of 200 nm fluorescent nano-particles. The advantages of the proposed algorithm are its speed and accuracy, which means that if enough objects are included, the real alignment precision is better than the axial localization precision of a single object. The alignment precision can be assessed directly from the algorithm's output. Thus, the method can be applied not only for image alignment and object matching in tilted view series in order to reconstruct (3D) images, but also to validate the experimental performance (e.g. mechanical precision of the tilting). In practice, the key application of the method is an improvement of the effective spatial (3D) resolution, because the well-known spatial anisotropy in light microscopy can be overcome. This allows more precise distance measurements between point-like objects.

Image Processing, Computer-Assisted↗

Combined confocal and wide-field high-resolution cytometry of fluorescent in situ hybridization-stained cells.

BACKGROUND: The recently developed technique of high-resolution cytometry (HRCM) enables automated acquisition and analysis of fluorescent in situ hybridization (FISH)-stained cell nuclei using conventional wide-field fluorescence microscopy. The method has now been extended to confocal imaging and offers the opportunity to combine the advantages of confocal and wide-field modes. METHODS: We have automated image acquisition and analysis from a standard inverted fluorescence microscope equipped with a confocal module with Nipkow disk and a cooled digital CCD camera. The system is fully controlled by a high-performance computer that performs both acquisition and related on-line image analysis. The system can be used either for an automatic two (2D) and three-dimensional (3D) analysis of FISH- stained interphase nuclei or for a semiautomatic 3D analysis of FISH-stained cells in tissues. The user can select which fluorochromes are acquired using wide-field mode and which using confocal mode. The wide-field and confocal images are overlaid automatically in computer memory. The developed software compensates automatically for both chromatic color shifts and spatial shifts caused by switching to a different imaging mode. RESULTS: Using the combined confocal and wide-field HRCM technique, it is possible to take advantage of both imaging modes. Images of some dyes (such as small hybridization dots or counterstain images of individual interphase nuclei) do not require confocal quality and can be acquired quickly in wide-field mode. On the contrary, images of other dyes (such as chromosome territories or counterstain images of cells in tissues) do require improved quality and are acquired in confocal mode. The dual-mode approach is two to three times faster compared with the single-mode confocal approach and the spectrum of its applications is much broader compared with both single-mode confocal and single-mode wide-field systems. CONCLUSIONS: The combination of high speed specific to the wide-field mode and high quality specific to the confocal mode gives optimal system performance.

Cell Nucleus↗

An efficient algorithm for measurement and correction of chromatic aberrations in fluorescence microscopy.

Even the best optical microscopes available on the market exhibit chromatic aberrations to some extent. In some types of study, chromatic aberrations of current optics cannot be neglected and a software correction is highly desirable. This paper describes a novel method of chromatic aberration measurement and software correction using sub-resolution bead imaging and computer image analysis. The method is quick, precise and enables the determination of both longitudinal and lateral chromatic aberrations. Correction function can be computed in about half an hour, including image acquisition. Using this approach, chromatic aberrations can be reduced to 10-20 nm laterally and 10-60 nm axially depending on the type of optical set-up. The method is especially suitable for fluorescence microscopy, where a limited number of wavelengths are observed.

Journal Article↗

Topography of genetic loci in tissue samples: towards new diagnostic tool using interphase FISH and high-resolution image analysis techniques.

Using single and dual colour fluorescence in situ hybridisation (FISH) combined with image analysis techniques the topographic characteristics of genes and centromeres in nuclei of human colon tissue cells were investigated. The distributions of distances from the centre-of-nucleus to genes (centromeres) and from genes to genes (centromeres to centromeres) were studied in normal colon tissue cells found in the neighbourhood of tumour samples, in tumour cell line HT-29 and in promyelocytic HL-60 cell line for comparison. Our results show that the topography of genetic loci determined in 3D-fixed cell tissue corresponds to that obtained for 2D-fixed cells separated from the tissue. The distributions of the centre-of-nucleus to gene (centromere) distances and gene to gene (centromere to centromere) distances and their average values are different for various genetic loci but similar for normal colon tissue cells, HT-29 colon tumour cell line and HL-60 promyelocytic cell line. It suggests that the arrangement of genetic loci in cell nucleus is conserved in different types of human cells. The investigations of trisomic loci in HT-29 cells revealed that the location of the third genetic element is not different from the location of two homologues in diploid cells. We have shown that the topographic parameters used in our experiments for different genetic elements are not tissue or tumour specific. In order to validate high-resolution cytometry for oncology, further investigations should include more precise parameters reflecting the state of chromatin in the neighbourhood of critical oncogenes or tumour suppresser genes.

Cell Nucleus↗

Clinical path coordinator: pulling it all together.

Institutions across the country are using different approaches to restructuring health care delivery systems. At Lehigh Valley Hospital collaborative practice was instituted to ensure the achievement of patient outcomes within appropriate time frames and with efficient use of resources. The role of the clinical path coordinator emerged from the collaborative practice model developed to manage the care of the patient with an abdominal aortic aneurysm. The step-by-step process for selecting, orienting, and implementing the role of the coordinator is discussed. Since the implementation of the coordinator role, patient satisfaction has been positive, length of stay and cost have decreased, and quality of care has improved for these patients.

Aortic Aneurysm, Abdominal↗

Protein S deficiency: a case study.

Protein S deficiency, a life-threatening defect in the body's protective mechanism against activated coagulation, can result in recurrent or atypical patterns of thrombosis. A case study describing diagnosis and treatment of protein S deficiency and the nursing care of a patient requiring a vena cava filter is presented. It is important for nurses to be aware of the vital role they play in assessing, managing, and assisting both the patient and family as they adjust to this rare disorder.

Adult↗