PubMed Health⌕ Search

PubMed · 12588530

Precise 3D image alignment in micro-axial tomography.

Abstract

Micro (micro-) axial tomography is a challenging technique in microscopy which improves quantitative imaging especially in cytogenetic applications by means of defined sample rotation under the microscope objective. The advantage of micro-axial tomography is an effective improvement of the precision of distance measurements between point-like objects. Under certain circumstances, the effective (3D) resolution can be improved by optimized acquisition depending on subsequent, multi-perspective image recording of the same objects followed by reconstruction methods. This requires, however, a very precise alignment of the tilted views. We present a novel feature-based image alignment method with a precision better than the full width at half maximum of the point spread function. The features are the positions (centres of gravity) of all fluorescent objects observed in the images (e.g. cell nuclei, fluorescent signals inside cell nuclei, fluorescent beads, etc.). Thus, real alignment precision depends on the localization precision of these objects. The method automatically determines the corresponding objects in subsequently tilted perspectives using a weighted bipartite graph. The optimum transformation function is computed in a least squares manner based on the coordinates of the centres of gravity of the matched objects. The theoretically feasible precision of the method was calculated using computer-generated data and confirmed by tests on real image series obtained from data sets of 200 nm fluorescent nano-particles. The advantages of the proposed algorithm are its speed and accuracy, which means that if enough objects are included, the real alignment precision is better than the axial localization precision of a single object. The alignment precision can be assessed directly from the algorithm's output. Thus, the method can be applied not only for image alignment and object matching in tilted view series in order to reconstruct (3D) images, but also to validate the experimental performance (e.g. mechanical precision of the tilting). In practice, the key application of the method is an improvement of the effective spatial (3D) resolution, because the well-known spatial anisotropy in light microscopy can be overcome. This allows more precise distance measurements between point-like objects.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Matula, M Kozubek, F Staier, M Hausmann. 2003. Precise 3D image alignment in micro-axial tomography.. https://doi.org/10.1046/j.1365-2818.2003.01104.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Changes in particle area measurements due to SEM accelerating voltage and magnification.

Scanning electron microscopy (SEM) images of polymer blends followed by digital image analysis is a rapid and easy method for the measurement of particle size and dispersion. The particle size determination is done with appropriate off-line image analysis software. However, it is necessary to understand how machine parameters involved in the formation of the SEM image influence area measurements of morphological features. In this work, the influence of the accelerating voltage used during image acquisition was examined with standard samples and with polymer blend samples. A systematic study centered on two mutually exclusive assumptions of area variation or no area variation with accelerating voltage was carried out. The off-line image analysis software was then calibrated according to the assumptions. The main conclusion of this study was that kV has an important influence on area measurement in SEM images. This effect was observed for different standard materials (metallic and polymeric) and for the range of magnifications used. The higher the accelerating voltages, the greater the error at high magnification for polymer samples. As the beam energy increases, the primary electrons penetrate more deeply into the solid specimen, producing low-resolution signals. These signals degrade the image and surface details, which became less well defined. Therefore, images of polymer samples must be taken at lower accelerating voltages so the desired surface details can be imaged clearly. To avoid area measurement errors, particle measurement must be done with the calibration of the off-line image analysis software corresponding to the accelerating voltage and magnification used for the acquired images.

Image Processing, Computer-Assisted↗

Projected index computed tomography.

Projected index computed tomography (PICT) is a new imaging technique that provides a computed reconstruction of the index of refraction of a sample. PICT makes use of data from standard optical coherence tomography images taken from several view angles to determine a mapping of the refractive indices of the sample. A rectilinear propagation model is assumed, so the data are understood to be related to the line integral of the refractive index in the beam paths. These data thus provide a set of angular projections of the sample. The spatial distribution of the index of the object may then be reconstructed by use of standard filtered backprojection techniques. The resultant PICT images are free of the spatial distortion that is inherent in standard optical cross-sectional images and correspond well to the manufactured dimensions of specific samples.

Image Processing, Computer-Assisted↗

Nanodissection and high-resolution imaging of the Rhodopseudomonas viridis photosynthetic core complex in native membranes by AFM. Atomic force microscopy.

In photosynthesis, highly organized multiprotein assemblies convert sunlight into biochemical energy with high efficiency. A challenge in structural biology is to analyze such supramolecular complexes in native membranes. Atomic force microscopy (AFM) with high lateral resolution, high signal-to-noise ratio, and the possibility to nanodissect biological samples is a unique tool to investigate multiprotein complexes at molecular resolution in situ. Here we present high-resolution AFM of the photosynthetic core complex in native Rhodopseudomonas viridis membranes. Topographs at 10-A lateral and approximately 1-A vertical resolution reveal a single reaction center (RC) surrounded by a closed ellipsoid of 16 light-harvesting (LH1) subunits. Nanodissection of the tetraheme cytochrome (4Hcyt) subunit from the RC allows demonstration that the L and M subunits exhibit an asymmetric topography intimately associated to the LH1 subunits located at the short ellipsis axis. This architecture implies a distance distribution between the antenna and the RC compared with a centered location of the RC within a circular LH1, which may influence the energy transfer within the core complex. The LH1 subunits rearrange into a circle after removal of the RC from the core complex.

Image Processing, Computer-Assisted↗