Development of membrane extraction with a sorbent interface-micro gas chromatography system for field analysis.

The commercially available portable gas chromatographs have a rather limited scope of applications, typically allowing analysis of gaseous samples only, and having relatively poor sensitivity. Combination of those instruments with modern sampling/sample preparation techniques can remedy these problems. A Chrompack micro-GC system equipped with a thermal conductivity detector has been coupled to membrane extraction with a sorbent interface (MESI). The sorbent trap has replaced the GC injector. The design of the trap was also modified in order to enhance the preconcentration of analytes. The use of a thin flat sheet membrane reduces the response time, and decreases the memory effect of the system. Rapid separation times were achieved, and the sensitivity was significantly improved. MESI enables semi-continuous monitoring of both gaseous and aqueous samples, owing to the selectivity of the membrane material. The system does not use moving parts, therefore being reliable. The sensitivity of the micro-GC system was increased by a factor of more than 100 by the addition of the MESI system, even with a preconcentration time as short as 1 min. Chloroform, having a concentration lower than 1 ppb, was detected in tap water. A cup system was used to allow headspace sampling of volatile organic compounds from aqueous matrices, keeping the membrane away from interfering species that could be present in water, and improving the mass transfer. A linear calibration line was obtained, and the estimated limit of detection was 60 ppt. This represents a great improvement for the sensitivity of the micro-GC system.

Chromatography, Gas↗

Novel preconcentration technique for on-line coupling to high-speed narrow-bore capillary gas chromatography: sample enrichment by equilibrium (ab)sorption. II. Coupling to a portable micro gas chromatograph.

The technique of equilibrium (ab)sorption has been proven to be a powerful method for preconcentration of gaseous samples for high-speed narrow-bore capillary gas chromatography (GC) in general and field-portable GC instruments, often referred as micro GCs, in particular. Using a simple experimental set-up equipped with an open-tubular enrichment column it is possible to produce a homogeneously enriched sample plug, allowing reproducible injections of an enriched sample into the micro GC. Using a non-polar trapping column enrichment factors found for n-alkanes in the range of C7 to C10 ranged from 15 to 150 and agree well with calculated values. Using a highly retentive Thermocap column, the enrichment factor observed for heptane was above 500. As the use of this new preconcentration method requires only minimum modification of the micro GC, the chromatographic performance of the instrument was not compromised by direct coupling to the preconcentration device. Examples of on-line enrichment with portable micro GC analysis of VOCs from air are shown. These examples clearly demonstrate the potentials of the new method in field analysis.

Absorption↗

Fully automated sample handling system for liquid chromatography based on pre-column technology and automated cartridge exchange.

The design of an automated cartridge exchange module for on-line sample handling in liquid chromatography is described. When combined with a low-cost purge pump, a solvent selection valve and an auto-sampler, a fully automated sample handling system is obtained. Samples are sorbed on a disposable cartridge packed with 40 micron octyl-bonded silica, purged for clean-up and eluted on-line to the analytical column. Unattended operation of the system is demonstrated for various examples, i.e., the determination of anti-epileptic drugs in serum, an anti-cancer drug in plasma, barbiturates in urine, phenylurea herbicides in river water and caffeine in a soft drink.