PubMed Health⌕ Search

Biomedical subjects

P Varcin

Publications and source records attributed to P Varcin.

7 recordsLinked to original sources

Synthesis of new hydrophilic microspheres: optimized carriers for microparticle-enhanced nephelometric immunoassays.

To optimize antigen-antibody reactions, we have synthesized chemically well-defined hydrophilic microspheres. Proteins or haptens were covalently linked to these carriers. When the microsphere conjugates were agglutinated by the corresponding antiserum, the size of the complex artificially increased during the immunological reaction. After optimizing various parameters such as the hydrophilic character, repulsion charges, and amount of antigen coupled to the microspheres, we developed a rapid and sensitive immunoassay based on laser light scattering by the complexes.

Animals↗

Microparticle-enhanced nephelometric immunoassay for human C-reactive protein.

Polyfunctional hydrophilic microspheres of 125-nm diameter can be produced by copolymerization of acrylic monomers. Purified c-reactive protein (CRP) was covalently bound to these new micropheres, and the conjugate obtained was used as reagent in a microparticle-enhanced nephelometric immunoassay for human CRP. This assay was based on the measure, with a specially designed nephelometer, of the light scattered by aggregates formed during the immunoagglutination of the conjugate with anti-CRP antiserum. Sensitive inhibition of this agglutination by free CRP (6 ng/ml) allowed CRP quantitation in highly diluted serum samples (1/500-1/2,000), excluding any interference or sample pretreatment. The CRP assay was easy to perform (no washing or phase separation), reliable (coefficients of variation ranged from 1.3% to 9.3% for within-run and between-run determinations), and accurate (mean percentage of recovery: 104%; correlation coefficients with accepted analytical methods greater than or equal to 0.97) over a large range of concentrations. The inhibition mode excluded errors in the antigen excess zone and provided total security at high concentrations.

C-Reactive Protein↗

Development of a rapid microparticle-enhanced nephelometric immunoassay for serum myoglobin in acute myocardial infarction.

A microparticle-enhanced nephelometric immunoassay was developed for myoglobin quantitation in human serum. It uses rabbit antimyoglobin serum and hydrophilic polyacrylic microparticles covalently coated with baboon myoglobin in a competitive immunoagglutination system. The level of microparticle agglutination is assessed with a specially designed nephelometer. This sensitive (45 ng/ml of myoglobin detected in serum) and accurate (coefficients of variation from 3.0% to 8.2% in precision study and linear recovery of myoglobin in overloaded sera) immunoassay was evaluated with human sera from patients suffering from acute myocardial infarction. Myoglobin levels in patient's serum on admission appeared to be correlated with clinical and biological parameters assessed in emergency wards and later. This new, rapid, and easy microparticle-enhanced nephelometric immunoassay could thus be useful in emergency conditions for the early quantitation of serum myoglobin.

Adult↗

Measurement of eleven serum proteins by microparticle-enhanced nephelometric immunoassay.

Eleven proteins (immunoglobulins IgG, IgA, IgM, orosomucoid, alpha 1-antiproteinase, haptoglobin, ceruloplasmin, C-reactive protein, transferrin, prealbumin and alpha 2-macroglobulin) in human serum were quantitated by a new microparticle-enhanced nephelometric immunoassay. This is a one step competitive assay, based on the nephelometric measurement of light scattered by clusters of protein-coated microparticles specially synthesized for that use. Statistical evaluation (precision, recovery and method comparison) shows that the determination of serum proteins is reliable and accurate for wide ranges of concentration and that the method is quite adequate for strongly increased concentrations. This microparticle-enhanced nephelometric immunoassay appears to offer an alternative method for routine measurement of a great variety of serum proteins at high and intermediate concentrations, which are usually quantified by radial immunodiffusion or conventional immunonephelometry. On account of its sensitivity, it can also be used for the determination of relatively low concentrations of analytes.

Blood Proteins↗

Polyacrylic microspheres as a solid phase for microparticle enhanced nephelometric immunoassay (NEPHELIA (R)) of transferrin.

Polyfunctional hydrophilic microspheres (MS) can be produced by copolymerisation with gamma-irradiation of acrylic monomers. Transferrin (TRF) can be covalently bound to these MS by reaction between aldehyde groups of the MS and primary amino groups of the protein. MS-TRF conjugates thus obtained are agglutinated by specific antiserum and this agglutination is inhibited by free TRF. Agglutination and inhibition are quantified by measurement of the light scattered by MS-TRF conjugate clusters with a specially designed nephelometer, a process designated as microparticle enhanced nephelometric immunoassay (NEPHELIA (R)) for TRF. Recovery, correlation and reproducibility studies, simultaneously performed in three different laboratories, show that this TRF immunoassay is accurate for a large concentration range. NEPHELIA (R) may appear as an alternative method for a large variety of molecules.

Humans↗

Microparticle-enhanced nephelometric immunoassay (Nephelia) for immunoglobulins G, A, and M.

Covalent binding of gamma chains of IgG, whole IgA, and mu chains of IgM on polyfunctional hydrophilic microspheres (MS) yields MS-Ig conjugates, usable as reagents in new microparticle-enhanced nephelometric immunoassays (Nephelia). The principle of the assays is inhibition by free analyte (IgG, IgA, and IgM) of agglutination of the MS-Ig conjugate with specific antiserum, the light scattered by the aggregates being measured with a nephelometer. The immunoglobulin assays developed are easy to perform (single-step assays, no washing or phase separation) and sensitive (high dilution of biological samples to exclude interferences and pretreatment). Analytical recovery results (95.4-101.2%) and correlations with generally used commercial assays (r = 0.86-0.98) indicate that the assays are accurate for large concentration ranges of immunoglobulins. Precision study gives CVs = 2.8-9.6%. Nephelia appears to be useful for quantifying a large variety of biological molecules.

Humans↗

Microparticle-enhanced nephelometric immunoassay with microsphere-antigen conjugates.

gamma-Irradiation of acrolein and other acrylic monomers allowed the synthesis of spherical polyfunctional hydrophilic microparticles in the size range of 50 to 300 nm, on which antigens (immunoglobulins G, chorionic gonadotropin hormone, prealbumin) could be covalently bound. Microsphere-antigen conjugates clustered together in the presence of specific antiserum or monoclonal antibodies and their agglutination was quantified by light-scattering measurement performed with a specially designed nephelometer. Essential factors concerning the conjugate agglutination and its quantitation (size of microsphere, amount of antigen bound on microsphere, concentration of conjugate, concentration of agglutinating reagent, angle of light-scattering observation) were successively studied. A microparticle-enhanced nephelometric immunoassay for prealbumin was finally developed as an example of application. It was based on the inhibition of the immunoagglutination of microspheres-prealbumin conjugate by free prealbumin. This prealbumin immunoassay was easy to perform (one-step assay without washing or phase separation), fast (30 min), reliable (variation coefficients ranged from 3.6% to 7.5% for within- and between-assay determination), and sensitive (1 microgram/L detected). It was correlated with conventional immunonephelometry and radial immunodiffusion (correlation coefficients, 0.98). Microparticle-enhanced nephelometric immunoassay offered many advantages over the last two methods. Its better sensitivity allowed a lower reagent consumption and a larger sample dilution (contrary to the conventional immunonephelometry, sample pretreatment and sample blank measurement were unnecessary). Its inhibition mode induced a total accuracy for sample with high analyte concentration (a risk of underevaluation in antigen excess conditions existed in all method based on a noncompetitive antigen-antibody reaction) and provided the possibility to quantify haptens.(ABSTRACT TRUNCATED AT 250 WORDS)

Acrolein↗