PubMed Health⌕ Search

Biomedical subjects

P Yager

Publications and source records attributed to P Yager.

At least 19 recordsLinked to original sources

Concentration and separation of proteins in microfluidic channels on the basis of transverse IEF.

The use of microfluidic channels formed by two electrodes made of gold or palladium to perform transverse isoelectric focusing (IEF) is presented as a means for continuous concentration and fractionation of proteins. The microchannels were 40 mm long with an electrode gap of 1.27 mm and a depth of 0.354 mm. The properties of pH gradients formed as a result of the electrolysis of water were influenced by variation of parameters such as the initial pH, ionic strength, and flow rate. Transverse IEF in pressure-driven flow is demonstrated using bovine serum albumin in a single ampholyte buffer as well as in multiple-component buffers. Experimental results of protein focusing compare well to predictions of a mathematical model. Optimal conditions for efficient continuous fractionation of a protein mixture are summarized and discussed.

Animals↗

Formation of natural pH gradients in a microfluidic device under flow conditions: model and experimental validation.

A new isoelectric focusing technique has been developed that incorporates natural pH gradient formation in microfluidic channels under flowing conditions. In conjunction, a one-dimensional finite difference model has been developed that solves a system of algebraic-ordinary differential equations that describe the phenomena occurring in the system, including hydrolysis at the electrodes, buffering effects of weak acids and bases, and mass transport due to both diffusion and electrophoresis. A quantitative, noninvasive, optically based method of monitoring pH gradient formation is presented, and the experimental data generated by this method are found to be in good agreement with model predictions. In addition, the model provides a theoretical explanation for initially unexpected experimental results. Model predictions are also shown to match well with experimental results of microfluidic isoelectric focusing of a single protein species. Accounting for the nonuniform velocity profile, characteristic of pressure-driven flow in microfluidic channels, is found to improve predictions of dynamic pH changes close to the electrodes and overall time required to reach steady state, but to reduce the accuracy of dynamic pH change predictions in other regions of the channel.

Journal Article↗

Continuous and highly variable rate controlled release of model drugs from sphingolipid-based complex high axial ratio microstructures.

Sphingolipids have been synthesized that contain as polar headgroups, model drugs ester-linked to the primary hydroxyl group of the ceramide core. These lipids, when allowed to self assemble below their chain-melting temperatures, either as single molecular species or in combination with other sphingolipid-derived amphiphiles, are shown to form supramolecular assemblies of varying morphologies including complex high axial ratio microstructures (CHARMs). Within these microstructures, the lipid esters are highly resistant to hydrolysis as compared to the esters dispersed as solitary monomers in aqueous solution or in a matrix of fluid phosphatidylcholine vesicles. The rate of headgroup hydrolysis within CHARMs may be manipulated over a broad range (days to years) by varying the length of the amide-linked fatty acyl chain in the ceramide core or the distance between the ester and the C-1 ceramide of the core. These microstructures, which have exceptionally high surface area display of attached headgroups, may be useful for controlled release of pharmacological agents.

Ceramides↗

Continuous concentration of bacteria in a microfluidic flow cell using electrokinetic techniques.

A novel method for the concentration of bacterial solutions is presented that implements electrokinetic techniques, zone electrophoresis (ZE) and isoelectric focusing (IEF), in a microfluidic device. The method requires low power (< 3e-5 W) and can be performed continuously on a flowing stream. The device consists of two palladium electrodes held in a flow cell constructed from layers of polymeric film held together by a pressure-sensitive adhesive. Both ZE and IEF are performed with carrier-free solutions in devices in which the electrodes are in intimate contact with the sample fluid. IEF experiments were performed using natural pH gradients; no carrier ampholyte solution was required. Experiments performed in buffer alone resulted in significant electroosmotic flow. Pretreatment of the sample chamber with bleach followed by a concentrated solution of cationic detergent effectively suppressed electroosmotic flow.

Bacteria↗

Theoretical analysis of molecular diffusion in pressure-driven laminar flow in microfluidic channels.

The T-sensor is a microfluidic analytical device that operates at low Reynolds numbers to ensure entirely laminar flow. Diffusion of molecules between streams flowing side by side may be observed directly. The pressure-driven velocity profile in the duct-shaped device influences diffusive transport in ways that affect the use of the T-sensor to measure molecular properties. The primary effect is a position-dependent variation in the extent of diffusion that occurs due to the distribution of residence time among different fluid laminae. A more detailed characterization reveals that resultant secondary concentration gradients yield variations in the scaling behavior between diffusive displacement and elapsed time in different regions of the channel. In this study, the time-dependent evolution of analyte distribution has been quantified using a combination of one- and two-dimensional models. The results include an accurate portrayal of the shape of the interdiffusion region in a representative T-sensor assay, calculation of the diffusive scaling law across the width of the channel, and quantification of artifacts that occur when making diffusion coefficient measurements in the T-sensor.

Biophysical Phenomena↗

Optical measurement of transverse molecular diffusion in a microchannel.

Quantitative analysis of molecular diffusion is a necessity for the efficient design of most microfluidic devices as well as an important biophysical method in its own right. This study demonstrates the rapid measurement of diffusion coefficients of large and small molecules in a microfluidic device, the T-sensor, by means of conventional epifluorescence microscopy. Data were collected by monitoring the transverse flux of analyte from a sample stream into a second stream flowing alongside it. As indicated by the low Reynolds numbers of the system (< 1), flow is laminar, and molecular transport between streams occurs only by diffusion. Quantitative determinations were made by fitting data with predictions of a one-dimensional model. Analysis was made of the flow development and its effect on the distribution of diffusing analyte using a three-dimensional modeling software package. Diffusion coefficients were measured for four fluorescently labeled molecules: fluorescein-biotin, insulin, ovalbumin, and streptavidin. The resulting values differed from accepted results by an average of 2.4%. Microfluidic system parameters can be selected to achieve accurate diffusion coefficient measurements and to optimize other microfluidic devices that rely on precise transverse transport of molecules.

Biochemistry↗

The relationship between the structure of the headgroup of sphingolipids and their ability to form complex high axial ratio microstructures.

Ceramides with chemically modified polar headgroups were prepared and examined for their ability to form complex high axial ratio microstructures (CHARMS), potential drug delivery vehicles. In general, if the modified ceramide had either a hydrogen bond donor or acceptor at C-1 and C-3, including hydrophobic or hydrophilic groups attached to C-1 microstructures formed. Tolerated groups include amides, esters, sulfonates, and ethers. If modification at C-3 added significant bulk (greater than four carbons regardless of hydrophilicity), then amorphous aggregates formed. Ceramides with C-1 and C-3 bridged through a cyclic structure also made microstructures. By using a sphingolipid with an amine headgroup, CHARMs may be modified covalently after formation.

Magnetic Resonance Spectroscopy↗

Testosterone delivery using glutamide-based complex high axial ratio microstructures.

Complex high axial ratio microstructures (CHARMs) were evaluated for delivery of testosterone in vivo. Methods to incorporate testosterone included noncovalent mixing and covalent attachment of testosterone to the lipid to form a prodrug monomer. When prepared by covalent attachment, testosterone-loaded CHARMs were resistant to in vitro spontaneous hydrolysis; when injected into rats, testosterone was released with biphasic kinetics consisting of a burst followed by a much slower phase. Some CHARM material associated with testosterone persisted at the site of injection for at least 9 days.

Animals↗

A rapid diffusion immunoassay in a T-sensor.

We have developed a rapid diffusion immunoassay that allows measurement of small molecules down to subnanomolar concentrations in <1 min. This competitive assay is based on measuring the distribution of a labeled probe molecule after it diffuses for a short time from one region into another region containing antigen-specific antibodies. The assay was demonstrated in the T-sensor, a simple microfluidic device that places two fluid streams in contact and allows interdiffusion of their components. The model analyte was phenytoin, a typical small drug molecule. Clinically relevant levels were measured in blood diluted from 10- to 400-fold in buffer containing the labeled antigen. Removal of cells from blood samples was not necessary. This assay compared favorably with fluorescence polarization immunoassay (FPIA) measurements. Numerical simulations agree well with experimental results and provide insight for predicting assay performance and limitations. The assay is homogeneous, requires <1 microl of reagents and sample, and is applicable to a wide range of analytes.

Antibody Specificity↗

Generation of natural pH gradients in microfluidic channels for use in isoelectric focusing

As a part of an ongoing investigation of the use of isoelectric focusing (IEF) in microfluidic devices, pH gradients were electrochemically formed and optically quantified in microfluidic channels using acid-base indicators. The microchannels consisted of two parallel 40-mm-long electrodes with an interelectrode gap of 2.54 mm; top and bottom transparent windows were separated by 0.2 mm. Gradients in pH were formed as a result of the electrochemical decomposition of water at an applied potential not higher than 2.5 V to avoid generation of gas bubbles. Solutions contained low concentrations of a single buffer. The stability of the pH gradients and their sensitivity to changes in initial conditions were investigated under static (nonflow) conditions. Isoelectric focusing of sample biological analytes, bovine hemoglobin and bovine serum albumin, was performed to illustrate the potential of "microfluidic transverse IEF" for use in continuous concentration and separation systems.

Journal Article↗

Rabies in an American bison from North Dakota.

In North Dakota (USA) during April 1998, a ranched female bison (Bison bison) was found dead. At gross necropsy, there was profound hair loss and consolidated lung lobes. Intracytoplasmic neuronal inclusions suggestive of Negri bodies were observed in the brain stem and hippocampus, and a diagnosis of rabies was confirmed by the fluorescent antibody test. Antigenic typing demonstrated the occurrence of a rabies virus variant associated with skunks from the upper midwestern USA. This case of a rabid bison was one of only four such instances recorded from the USA over the past 40 yr, and is the first case report of rabies in a bison that reports clinical, pathologic, and antigenic findings. Although rabies in bison is rare, veterinarians and wildlife managers that work closely with such non-traditional species are reminded of the dangers that zoonoses such as rabies present.

Alopecia↗

Quantitative analysis of molecular interaction in a microfluidic channel: the T-sensor.

The T-sensor is a recently developed microfluidic chemical measurement device that exploits the low Reynolds number flow conditions in microfabricated channels. The interdiffusion and resulting chemical interaction of components from two or more input fluid streams can be monitored optically, allowing measurement of analyte concentrations on a continuous basis. In a simple form of T-sensor, the concentration of a target analyte is determined by measuring fluorescence intensity in a region where the analyte and a fluorescent indicator have interdiffused. An analytical model has been developed that predicts device behavior from the diffusion coefficients of the analyte, indicator, and analyte--indicator complex and from the kinetics of the complex formation. Diffusion coefficients depend on the local viscosity which, in turn, depends on local concentrations of all analytes. These relationships, as well as reaction equilibria, are often unknown. A rapid method for determining these unknown parameters by interpreting T-sensor experiments through the model is presented.

Kinetics↗

Formation of high axial ratio microstructures from peptides modified with glutamic acid dialkyl amides.

A growing number of amphiphiles are known to form high axial ratio microstructures (HARMs) such as the hollow cylindrical microstructures called lipid tubules. As a prelude to exploring the potential of HARMs formed from lipopeptides in controlled release drug delivery, several microstructure formation conditions were investigated. We report the preparation of several glutamic acid dialkyl amides with varying alkyl chain lengths bearing a verity of peptides (1-4 amino acids) [peptide-Glu-(NHCnH2n+1)2, n=12, 14, 16]. These surfactants have been rapidly and efficiently converted into HARMs in aqueous buffer at physiological pH and ionic strength, or in buffer containing MeOH or EtOH. Helical ribbons and tubular HARMs were produced that were stable for as long as 6 months below the phase transition temperatures of the compounds. To estimate the stability of HARMs in vivo, HARMs formed from (Pro)3-Glu(NHC16H33)2 were incubated with DOPC liposomes or fetal calf serum at 40 degreesC. HARM size and shape did not change significantly, suggesting that such lipopeptide particles can retain their morphology long enough in vivo to be useful as drug delivery vehicles.

Amides↗

Feasibility study of the spectroscopic measurement of oxyhemoglobin using whole blood without pre-treatment.

A feasibility study was carried out to evaluate a chemometrics-enhanced measurement of oxyhemoglobin concentration in whole blood without pre-treatment by lysing cellular components in the sample. Conventional in vitro multi-wavelength CO oximeters pre-process blood by sonication or detergent dilution to lyse blood cells to reduce light scattering. Two limitations result: (1) residual cell membrane fragments can seed surface biofouling and (2) dilution errors can occur. A full wavelength method using multivariate analysis in chemometrics was applied to correct the light scattering effect in the measurement of oxyhemoglobin concentration. Whole blood specimens were adjusted to different oxyhemoglobin concentrations with gas mixtures (N2, CO2 and O2). An Ocean Optics miniaturized spectrophotometer with a 100 microns pathlength optical cell was used for transmission measurements from 500 to 700 nm. Original spectra were smoothed and a second derivative transformation was performed to eliminate the baseline shift and slope changes from light scattering. Indirect calibration was applied to the second derivative spectra. Two-factor cross-validation by principle components regression on two sets of data showed r2 = 0.985 and 0.946 between predicted oxyhemoglobin concentration and those measured by an AVL 912 CO oximeter with RSD = 3.85 and 6.83%, respectively. Error analysis gave s = 2.36 x 10(-5) (RSD = 0.23%) on derivative absorbance for the spectrophotometer measurement alone. Specimen settling and specimen sampling gave imprecision on derivative absorbance of s = 6.17 x 10(-4) (RSD = 4.4%) and s = 4.52 x 10(-4) (RSD = 1.4%), respectively.

Feasibility Studies↗

Formation of high-axial-ratio-microstructures from natural and synthetic sphingolipids.

Amphiphiles that form high-axial-ratio-microstructures (HARMs) are being considered as novel materials for controlled release of drugs and other biologically functional molecules. HARMs consisting of tubules, ribbons, solid rods and helices are formed from sphingolipids by addition of water to a solution of amphiphile in DMF. Single molecular species of galactocerebroside (GalCer) containing long unsaturated fatty acid chains or natural GalCer containing mixed-length, non-hydroxy fatty acids (NFA-GalCer) or alpha-hydroxy fatty acids (HFA-GalCer) form cylindrical structures. In contrast, single molecular species of GalCer containing long saturated fatty acids form ribbons and helices. GalCer HARMs are typically under 100 nm in diameter and have lengths of several microns. The importance of the amide of GalCer for HARM formation was evaluated using psychosine, which forms solid fibers, whereas sphingosine and an analog of GalCer in which the amide is reduced to a secondary amine form amorphous aggregates. Single molecular species of ceramide containing long unsaturated fatty acid chains form cylindrical structures, whereas those with long saturated fatty acids form ribbons and helices. Short chain saturated ceramide also forms cylindrical structures. GalCer analogs with N-acetyl-glycine in place of the galactose form fibers whereas those with N-acetyl-proline yield amorphous material. The N-acetyl-proline-containing amphiphile can de doped into pure GalCer or NFA-GalCer without perturbing tubule formation.

Amides↗

Zero-order interfacial enzymatic degradation of phospholipid tubules.

The first study of enzymatic hydrolysis of phospholipid tubules is reported. Phosphatidylcholines with acyl chains containing diacetylene groups are known to form tubular microstructures in which the lipids are tightly packed and crystalline. These tubules can be used to probe the role of microstructural form in the mechanics of interfacial enzymatic degradation by such enzymes as phospholipase A2 (PLA2). Hydrolysis by PLA2 may occur most rapidly in regions having the greatest number of bilayer packing defects, such as those that must be found at tubule ends. A microstructure that degrades primarily from its ends should exhibit zero-order kinetics, because the area of the degrading tubule and remains constant as the length of the microstructure decreases. Free fatty acid concentration was measured to follow the generation of PLA2 hydrolysis products in suspensions of diacetylenic phospholipid tubules. The kinetics of tubule hydrolysis were essentially zero-order until conversion was complete, as predicted. However, microscopy of partially hydrolyzed tubules revealed the formation of multiple discrete anionic product domains along the length of degrading tubules as well as in insoluble reaction product microstructures. Furthermore, the rate of tubule hydrolysis was only moderately enhanced by increasing the number of tubule ends, which is consistent with the conclusion that tubule ends are not the only sites of hydrolysis. A model that reconciles the overall kinetics with the morphological evidence is proposed.

Calorimetry, Differential Scanning↗

Biotechnology at low Reynolds numbers.

The shrinking of liquid handling systems to the micron and submicron size range entails moving into the area of small Reynolds numbers. The fluid dynamics in this regime are very different from the macroscale. We present an intuitive explanation of how the different physics of small Reynolds numbers flow, along with microscopic sizes, can influence device design, and give examples from our own work using fluid flow in microfabricated devices designed for biological processing.

Biotechnology↗

Modeling success and failure of Langmuir-Blodgett transfer of phospholipid bilayers to silicon dioxide.

Formation of planar phospholipid bilayers on solid and porous substrates by Langmuir-Blodgett transfer of monolayers from the air-water interface could be of much greater utility if the process were not irreproducible and poorly understood. To that end the energetics of transferring two phospholipid monolayers to a hydrophilic surface has been examined. An approximate mathematical relationship is formulated that relates the surface pressure of the precursor monolayers to the tension within the bilayer created. Data are presented that demonstrate that bilayer transfer can be carried out reproducibly even with refractory phospholipids such as phosphatidylcholine, but only over a very narrow range of precursor monolayer surface pressures. This range is related to the lysis tension of the bilayer. The morphology of films formed within and below the successful range of surface pressures are examined by fluorescence microscopy, and the observed features are discussed in terms of the relationship above. These results provide practical guidelines for successful formation of lipid bilayers on hydrophilic surfaces; these guidelines should prove useful for research into the properties of biomembranes and for development of bilayer-based biosensors.

Biophysical Phenomena↗