Development of fast Fourier transformation continuous cyclic voltammetry as a highly sensitive detection system for ultra trace monitoring of penicillin V.

Fast continuous cyclic voltammetry was used as a detection method for penicillin V in a flow injection system. Additionally, a special computer-based numerical calculation method (using fast Fourier transformation) providing enhancement of the analyte signal and noise reduction is introduced here. During the measurements, the potential waveform (consisting of the potential steps of cleaning, stripping, and the potential ramp) was continuously applied to an Au disk microelectrode (12.5 microm in radius). In particular, the effects of accumulation potential, sweep rate, and delay time on the sensitivity and selectivity of the method were investigated. Eventually, the stripping time was found to be less than 300 ms, the detection limit of the method was 7.0x10(-12) M, and the associated relative standard deviation at 5.0x10(-6) M penicillin V was 2.3 for eight runs.

Electrochemistry↗

A sub-second fast Fourier transform-adsorptive voltammetric technique for the nano-level determination of guthion at a gold microelectrode in flowing solutions.

This research demonstrates the quick guthion monitoring with the help of a sensitive method called fast Fourier transformation continuous cyclic voltammetry (FFTCV). Fortunately, FFTCV illustrates the benefits of precision, determination speed, cost-effectiveness, accuracy and simplicity, in comparison with formerly reported techniques. In particular, this method was applied to a gold microelectrode in flowing solutions to detect the guthion concentration in its formulations. The effects of several parameters were examined regarding the sensitivity of the method. After a series of experiments, the detection limit of the method was found to be equal to 1.27 pg/mL, when the optimum conditions were imposed, which is a scan rate value of 40V/s, an accumulation time of 0.4s, an accumulation potential of 0mV and a pH value of 2. During the measurements performance, the integration range of currents included all the potential scan ranges, even the oxidation and reduction of the Au surface electrode, for the achievement of a sensitive determination. Then, the potential waveform, consisting of the potential steps for cleaning, accumulation and the step for the potential ramp, was applied to an Au disk microelectrode in a continuous way. It is also important to refer to the positive points, presented only by the use of this technique. Firstly, it is no longer necessary to remove the oxygen from the test solution. Furthermore, the quick determination of any such compound in many chromatographic methods is possible. Thirdly, the corresponding detection limit is of nanomolar level.

Azinphosmethyl↗

Sub-second adsorptive fast Fourier transform coulometric technique as a novel method for the determination of nanomolar concentrations of sodium valproate in its pharmaceutical preparation in flowing solution systems.

In this work, a novel electrochemical technique has been developed for determination of nanomolar concentration of sodium valproate in flow-injection systems. The detection was done by adsorptive fast Fourier transform coulometric (AFFTC), in which the potential waveform consists of potential steps for cleaning, accumulation, and a potential ramp that was continuously applied on an Au disk microelectrode. Moreover, a special computer program is introduced based on numerical method, for calculation of the analyte signal (which is the partial and total charge exchanges at the electrode surface) and noise reduction. The optimum parameters were: pH value of 2.0, scan rate value of 40 Vs(-1), accumulation potential of 200 mV and accumulation time of 0.3 s. Detection limit of the method for sodium valproate was 9.0x10(-9) M. The relative standard deviation of the method at 1.3x10(-7) M was 2.0% for 10 runs.

Electrochemistry↗

A green method for the electroorganic synthesis of new 1,3-Indandione derivatives.

This is an environmentally friendly method in the field of electroorganic reactions under controlled potential electrolysis, without toxic reagents at a carbon electrode in an undivided cell which involves the (EC) mechanism reaction and comprises two steps alternatively; (i) electrochemical oxidation and (ii) chemical reaction. In particular, the electrochemical oxidation of 4-tert-butylcatechol, 4-methylcatechol and 2,3-dihydroxybenzoic acid in the presence of 2-phenyl-1,3-indandione has been studied in a water-acetonitrile (90 : 10) mixture. The research includes the use of a variety of experimental techniques, such as cyclic voltammetry, controlled-potential electrolysis, and spectroscopic identification of products (FT-IR, (1)H-NMR, and MS spectrometry).

Carbon↗

Synthesis of N'-(1-pyridin-2-ylmethylene)-2-furohydrazide and its application in construction of a highly selective PVC-based membrane sensor for La(III) ions.

A highly La(III) ion-selective PVC membrane sensor based on N'-(1-pyridin-2-ylmethylene)-2-furohydrazide (NPYFH) as an excellent sensing material was successfully developed. The electrode shows a good selectivity for La(III) ion with respect to most common cations including alkali, alkaline earth, transition and heavy metal ions. The proposed sensor exhibits a wide linear response with slope of 19.2 +/- 0.6 mV per decade over the concentration range of 1.0 x 10(-6) - 1.0 x 10(-1) M, and a detection limit of 7.0 x 10(-7) M of La(III) ions. The sensor response is independent of pH in the range of 3.5-10.0. The proposed electrode was applied as an indicator electrode in potentiometric titration of La(III) ion with EDTA.

Furans↗

Selective and non-selective determination of heavy metal ions in flowing solutions by fast stripping cyclic voltammetry.

A simple and fast stripping voltammetric detection method has been designed for selective and non-selective measurements of heavy metal ions in a flow-injection system. A special computer numerical method is introduced for calculating the analyte signal and noise reduction, where the signal is calculated based on the partial and total charge exchange at electrode surface. For a selective determination, the currents are integrated in the range of the oxidation and reduction of the analyte. For non-selective measurements, the integration range is set for the whole potential scan range (including oxidation and reduction of the Au surface). The time for stripping has been shown to be less than 300 ms. The main advantages of the detection method are as follows: first, removal of oxygen from the measured solution is not required; second, it is sufficiently fast for the determination of heavy metal ions in various chromatographic analysis methods. The limit of detection for tested ions was between 3 x 10(-9) and 6 x 10(-10) M, and the relative standard deviation at 50 ppb Pb2+ was 4.7% for 10 runs.

Journal Article↗

Novel PVC-based copper(II) membrane sensor based on 2-(1'-(4'-(1''-hydroxy-2''-naphthyl)methyleneamino)butyl iminomethyl)-1-naphthol.

A copper(II) ion-selective PVC membrane sensor based on 2-(1'-(4'-(1''-hydroxy-2''-naphthyl)methyleneamino)butyl iminomethyl)-1-naphthol (BHNB) as a novel Schiff base containing a sensing material has been successfully developed. The sensor exhibits a good linear response of 29 mV per decade within the concentration range of 10(-1)-10(-6) M of Cu2+. The sensor shows good selectivity for copper(II) ion in comparison with alkali, alkaline earth, transition and heavy metal ions. The BHNB-based sensor is suitable for use with aqueous solutions of pH 3.5-7.0 and displays minimal interference by Sr(II), Cd(II), Hg(II), Zn(II) and Pb(II), which are known to interfere with other previously suggested electrodes. The proposed membrane electrode was used as a sensor for determining the Cu(II) content in black tea samples. It was also applied as an indicator electrode in the potentiometric titration of Cu2+ ions with EDTA.

Copper↗

Sulfate-selective PVC membrane electrode based on a strontium Schiff's base complex.

A strontium Schiff's base complex (SS) can be used as a suitable ionophore to prepare a sulfate-selective PVC-based membrane electrode. The use of oleic acid (OA) and hexadecyltrimethylammonium bromide (HTAB), as additives, and nitrobenzen (NB), dibutyl phthalate (DBP) and benzyl acetate (BA) as solvent mediators, were investigated. The best performance was observed with a membrane composition PVC: NB: SS: HTAB of 30%: 62%: 5%: 3% ratio. The resulting sensor works well over a wide concentration range (1.0 x 10(-2)-1.0 x 10(-6) M) with a Nernstian slope of -29.2 mV per decade of sulfate activity over a pH range 4.0-7.0. The limit of detection of the electrode is 5 x 10(-7) M. The proposed sensor shows excellent discriminating ability toward SO4(2-) ions with regard to many anions. It has a fast response time of about 15 s. The membrane electrode was used to the determination of zinc in zinc sulfate tablets. The sensor was also used as an indicator electrode in the potentiometric titration of SO4(2-) against barium ion.

Ion-Selective Electrodes↗