Aberrations after intraocular lens implantation.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Patricia Piers.
Explore the source record for details and available documents.
PURPOSE: To use powerful modeling techniques for predicting the optical performance of eyes implanted with different types of intraocular lenses (IOLs). This approach will allow performance of "virtual cataract surgery," with different IOL designs that can be used and physical parameters that may occur during actual surgery-in particular, in IOLs that correct spherical aberration. METHODS: A computer model was developed to predict the optical performance of individual eyes after IOL implantation. The approach was validated in a group of patients with eyes implanted with different IOLs. In these patients, corneal wavefront aberrations were calculated from elevations provided by videokeratography. Ocular aberrations were measured with a high-dynamic range Hartmann-Shack wavefront sensor. Misalignments (IOL tilt and decentration) were estimated with a new instrument, based on recording Purkinje images. This model of particular corneal aberrations and IOL parameters (intrinsic optical design details plus geometric location data) was used to estimate the total ocular aberrations after surgery and to compared them with actual aberrations measured directly with the wavefront sensor. RESULTS: The aberrations of implanted eyes predicted by the individualized optical models were well correlated with the actual aberration measured in each subject. This result indicates that the approach is adequate in evaluating the actual optical performance of different types of lenses. The model allows a large number of "virtual" surgeries to be performed, to test the performance of current or future IOL designs. CONCLUSIONS: A "virtual surgery" approach was designed to predict the optical performance in pseudophakic eyes. In each subject, it was possible to obtain the eye's optical performance with a particular IOL and biometric data after surgery. Specifically, this modeling can be used to evaluate the tolerances to misalignments and depth of focus of IOLs correcting spherical aberration in actual eyes. This approach is quite powerful and is especially applicable to the study of current and future aberration-correction IOL designs.
PURPOSE: To evaluate best corrected visual acuity (BCVA) and photopic and mesopic contrast sensitivity in pseudophakic patients implanted either with the aspheric intraocular lens (IOL) designed to correct for corneal spherical aberration or with a conventional IOL. SETTING: Three surgical centers participated this prospective randomized masked comparative study. METHODS: Thirty eyes of 30 patients after aspheric lens implantation (Pfizer/Pharmacia Tecnis Z9000) were compared with 30 eyes of 30 age-matched patients after conventional lens implantation (Alcon AcrySof SA60AT). Two to three months after surgery, best spectacle corrected distance visual acuity was measured using the Early Treatment Diabetic Retinopathy Study chart. Contrast sensitivity was measured by sinusoidal grating charts for distance at photopic (85 cd/m(2)) and mesopic (6 cd/m(2)) luminance level with optical correction in place. Tested spatial frequencies were 1.5, 3, 6, 12, and 18 cycles per degree (cpd). RESULTS: The mean BCVA was -0.053 +/- 0.044 logMAR in eyes with the aspheric Tecnis IOL and 0.006 +/- 0.059 logMAR in eyes with the conventional AcrySof IOL (P=.0001). Eyes with the aspheric IOL showed better contrast sensitivity at spatial frequencies of 3 cpd (P<.05) and 6, 12, and 18 cpd (P<.01) in photopic and in mesopic conditions. Peak improvement occurred at 18 cpd and was 36% (0.29 log units) in photopic and 54% (0.27 log units) in mesopic conditions. CONCLUSIONS: The aspheric Tecnis IOL yielded better BCVA and better distance contrast sensitivity than the conventional IOL. The differences were clinically significant for higher spatial frequencies. The results give some suggestions for further studies.
Explore the source record for details and available documents.
OBJECTIVES: To compare retinal image quality and optical corneal aberrations in patients in whom monofocal polymethyl methacrylate intraocular lenses (IOLs) were implanted with those in healthy subjects of a similar older age (60-70 years old) and to use the results to suggest improved optical designs of IOLs to maximize retinal image quality. METHODS: A double-pass apparatus was used to measure retinal image quality for 3-, 4-, and 6-mm pupil diameters. Corneal aberrations for a 4-mm pupil were calculated by a ray-tracing technique from the elevations provided by corneal topography. Two groups of 20 subjects of a similar older age were studied: in one group, polymethyl methacrylate monofocal IOLs were implanted; and in a second group, healthy subjects were used as a reference. RESULTS: The average retinal image quality was similar in older healthy patients and in patients in whom IOLs were implanted, with both groups having a significantly worse image quality than healthy younger subjects (aged 20-30 years). Both groups were more tolerant to defocus than younger subjects. CONCLUSIONS: The average retinal image quality of patients in whom IOLs were implanted was worse than that of healthy younger subjects despite the good optical quality of isolated IOLs. This apparent paradox can be understood by the nature of the aberration coupling in the eyes that undergo implantation. The ideal substitute for the natural lens is not an IOL with the best-isolated optical performance, but rather one designed to compensate for the aberrations of the cornea-a design somehow inspired by the crystalline lens of younger subjects.
We studied the age dependence of the relative contributions of the aberrations of the cornea and the internal ocular surfaces to the total aberrations of the eye. We measured the wave-front aberration of the eye with a Hartmann-Shack sensor and the aberrations of the anterior corneal surface from the elevation data provided by a corneal topography system. The aberrations of the internal surfaces were obtained by direct subtraction of the ocular and corneal wave-front data. Measurements were obtained for normal healthy subjects with ages ranging from 20 to 70 years. The magnitude of the RMS wave-front aberration (excluding defocus and astigmatism) of the eye increases more than threefold within the age range considered. However, the aberrations of the anterior corneal surface increase only slightly with age. In most of the younger subjects, total ocular aberrations are lower than corneal aberrations, while in the older subjects the reverse condition occurs. Astigmatism, coma, and spherical aberration of the cornea are larger than in the complete eye in younger subjects, whereas the contrary is true for the older subjects. The internal ocular surfaces compensate, at least in part, for the aberrations associated with the cornea in most younger subjects, but this compensation is not present in the older subjects. These results suggest that the degradation of the ocular optics with age can be explained largely by the loss of the balance between the aberrations of the corneal and the internal surfaces.
PURPOSE: To develop a prototype instrument that uses adaptive optics to introduce virtually any desired aberration profile in a subject's eye. At the same time, the instrument could be used to evaluate the subject's spatial vision for each controlled aberration profile. This "aberration testing station" or "visual simulator" allows us to study the relationship between specific aberrations and visual quality. METHODS: The apparatus uses infrared light to measure the wavefront aberration of the system plus the eye with a Hartmann-Shack wavefront sensor. Defocus is added (or removed) with a computer-controlled, motorized optometer, while higher order aberrations are introduced by a 37-channel membrane deformable mirror. A parallel viewing channel is used for visual testing with the instrument. Visual acuity, contrast sensitivity, and other visual tests are performed under normal viewing for each desired aberration profile. RESULTS: The range of defocus that can be added is nearly unlimited, while the maximum amount of other aberration modes is restricted to approximately 0.5 microm, depending on mode. Pure modes or any selected combination of modes can be produced with high repeatability and precision (usually better than 0.05 microm), and the system works for pupil diameters up to 6 mm (with a natural pupil). CONCLUSIONS: The adaptive optics visual simulator is a powerful, non-invasive tool to evaluate how aberrations affect vision. In addition, it can be used for the interactive design and testing of new ophthalmic devices, and for the simulation of visual outcomes in customized refractive surgery.
PURPOSE: We compared corneal and total higher order wavefront aberrations in 25 pseudophakic eyes implanted with five different types of intraocular lenses to obtain an objective evaluation of the optical quality of these pseudophakic eyes. Five IOLs per type were studied. METHODS: Implanted lenses were the Pharmacia Tecnis Z9000 with negative spherical aberration, Pharmacia 911 Edge, Alcon Acrysof SA60AT and MA60BM, and Allergan Sensar AR40e. Eyes were examined using the Topcon KR-9000PW topographer/aberrometer, which obtains simultaneous coaxial measurements of corneal and ocular aberrations, and displays the calculated Point Spread Function (PSF) and Modulation Transfer Function (MTF). RESULTS: Corneal spherical aberration was positive in all tested eyes. For a 4-mm optical zone, ocular spherical aberration was 0.0054+/-0.0172 microm root-mean-square (RMS) in eyes implanted with the Tecnis lens, and was 0.0562 to 0.0974 microm RMS in eyes implanted with the four other conventional IOLs. A myopic refractive shift with mydriasis of -0.08 D occurred with the Tecnis IOL; it was -0.57 to -0.90 D with the conventional IOLs. Coma did not show a substantial reduction with any of the IOLs. Total wavefront aberrations showed nonsignificant reduction with the Tecnis lens. The PSF and the MTF also showed nonsignificant improvements over conventional IOLs. CONCLUSIONS: The optical quality of pseudophakic eyes can be measured in vivo by aberrometers. Different IOLs resulted in measurably different outcomes. In this preliminary study, compensation of the spherical aberration observed with the Tecnis lens confirmed the theoretical predictions associated with this lens and resulted in no myopic shift in refraction with mydriasis.