PubMed Health⌕ Search

Biomedical subjects

Patrick Coon

Publications and source records attributed to Patrick Coon.

7 recordsLinked to original sources

Use of real-time 3-dimensional transthoracic echocardiography in the evaluation of mitral valve disease.

Three-dimensional (3D) echocardiography (3DE) provides unique orientations of the mitral valve (MV) not obtainable by routine 2-dimensional echocardiography. However, this modality has not been adopted in routine clinical practice because of its cumbersome and time-consuming process. The recent introduction of a full matrix-array transducer has enabled online real-time 3DE (RT3DE) and rendering. This study was designed to: (1) determine the clinical use of RT3DE in patients with MV pathology and in a control group selected for their good acoustic windows (protocol I); and (2) to investigate the feasibility of imaging the MV apparatus in a large group of consecutively imaged patients to determine the acoustic window or perspective from which the MV leaflets, commissures, and orifice are best visualized (protocol II). In protocol I, 65 patients were selected based on MV pathology and good 2-dimensional echocardiography image quality. Protocol II included 150 patients who were consecutively imaged using RT3DE. Images were viewed online (protocol I) and offline on a digital review station (protocol II). RT3DE visualization of the MV apparatus was graded based on the percentage of leaflet dropout and definition. In protocol I, 78% of patients had adequate 3D MV reconstructions with complete visualization of the anterior mitral leaflet (AML) in 84% versus the posterior mitral leaflet (PML) in 77%. The mitral leaflets, commissures, and MV orifice were well seen in 98%; however, the submitral apparatus was only observed in 76% of the patients. RT3DE: (1) correctly identified the prolapsed/flailed scallop in 6 of 8 patients; (2) obtained en face orientation of the MV orifice in 9 of 11 patients with mitral stenosis, allowing accurate measurements of the orifice area and evaluation of the immediate effects of balloon mitral valvuloplasty; and (3) allowed postoperative evaluation of MV repair and the integrity of the struts of a bioprosthetic leaflet. In protocol II, 70% of patients had adequate RT3DE with complete visualization of the AML noted in 55% versus 51% for PML. The mitral leaflets, commissures, and MV orifice were observed in 69%. Irrespective of acquisition window, the AML was best seen from a ventricular perspective. In contrast, the PML was optimally examined from a parasternal window. Both the medial and lateral commissures were equally assessed from either imaging window. In conclusion, RT3DE of the MV is feasible in a large majority of patients. Using different MV acquisitions RT3DE provides important clinical information such as: (1) identification of a prolapsed/flail scallop; (2) measurement of stenotic valve areas; (3) evaluation of MV leaflet integrity postrepair; and (4) identification of a MV perforation. In general the AML is better visualized than the PML. The parasternal window is the optimal approach to visualize both AML and PMLs.

Computer Systems↗

Quantification of regional left ventricular wall motion from real-time 3-dimensional echocardiography in patients with poor acoustic windows: effects of contrast enhancement tested against cardiac magnetic resonance.

OBJECTIVE: Regional left ventricular function can be assessed by real-time 3-dimensional echocardiography (RT3DE) in patients with good image quality. Our goals were to: (1) test the feasibility of RT3DE quantification of regional wall motion (RWM) in patients with poor acoustic windows who require contrast for endocardial visualization; and (2) validate these measurements against cardiac magnetic resonance (CMR) reference. METHODS: RT3DE datasets and CMR images were obtained in 24 patients. In 16 of 24 patients with suboptimal endocardial definition, RT3DE imaging was repeated with intravenous contrast and triggering at end systole and end diastole. RT3DE datasets were analyzed using custom software designed to semiautomatically detect and segment the endocardial surface and calculate RWM values. CMR images were analyzed using commercial software to obtain reference values for RWM. RESULTS: In 8 of 24 patients with good endocardial definition, RT3DE values of RWM correlated well with CMR (r = 0.73) with a small bias (-1.0 mm). In the remaining 16 patients, analysis of nonenhanced RT3DE datasets yielded lower correlation with CMR (r = 0.61) and a slightly greater bias (-1.5 mm). The agreement with CMR improved significantly (r = 0.76, bias -1.1 mm) with contrast enhancement. CONCLUSIONS: The agreement between RT3DE and CMR values of RWM is directly related to RT3DE image quality. In patients with poor acoustic windows, dual-triggered contrast enhancement improves the accuracy of RWM quantification to a level similar to that noted in patients with good images without contrast.

Computer Systems↗

Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data.

AIMS: Determination of left ventricular (LV) volumes and ejection fraction (EF) from two-dimensional echocardiographic (2DE) images is subjective, time-consuming, and relatively inaccurate because of foreshortened views and the use of geometric assumptions. Our aims were (1) to validate a new method for rapid, online measurement of LV volumes from real-time three-dimensional echocardiographic (RT3DE) data using cardiac magnetic resonance (CMR) as the reference and (2) to compare its accuracy and reproducibility with standard 2DE measurements. METHODS AND RESULTS: CMR, 2DE, and RT3DE datasets were obtained in 50 patients. End-systolic and end-diastolic volumes (ESV and EDV) were calculated from the 2DE images using biplane method of disks. ES and ED RT3DE datasets were analysed using prototype software designed to automatically detect the endocardial surface using a deformable shell model and calculate ESV and EDV from voxel counts. 2DE and RT3DE-derived volumes were compared with CMR (linear regression, Bland-Altman analysis). In most patients, analysis of RT3DE data required <2 min per patient. RT3DE measurements correlated highly with CMR (r: 0.96, 0.97, and 0.93 for EDV, ESV, and EF, respectively) with small biases (-14 mL, -6.5 mL, -1%) and narrow limits of agreement (SD: 17 mL, 16 mL, 6.4%). 2DE measurements correlated less well with CMR (r: 0.89, 0.92, 0.86) with greater biases (-23 mL, -15 mL, 1%) and wider limits of agreement (SD: 29 mL, 24 mL, 9.5%). RT3DE resulted in lower intra-observer (EDV: 7.9 vs. 23%; ESV: 7.6 vs. 26%) and inter-observer variability (EDV: 11 vs. 26%; ESV: 13 vs. 31%). CONCLUSION: Semi-automated detection of the LV endocardial surface from RT3DE data is suitable for clinical use because it allows rapid, accurate, and reproducible measurements of LV volumes, superior to conventional 2DE methods.

Echocardiography, Three-Dimensional↗

Quantitative diagnosis of stress-induced myocardial ischemia using analysis of contrast echocardiographic parametric perfusion images.

AIMS: Parametric imaging of myocardial perfusion provides useful visual information for the diagnosis of coronary artery disease (CAD). We developed a technique for automated detection of perfusion defects based on quantitative analysis of parametric perfusion images and validated it against coronary angiography. METHODS AND RESULTS: Contrast-enhanced, apical 2-, 3- and 4-chamber images were obtained at rest and with dipyridamole in 34 patients with suspected CAD. Images were analyzed to generate parametric perfusion images of the standard contrast-replenishment model parameters A, beta and A.beta. Each parametric image was divided into six segments, and mean parameter value (MPV) was calculated for each segment. Segmental MPV ratio between stress and rest was defined as a flow reserve index (FRI). Receiver operating characteristics (ROC) analysis was used in a Study group (N=17) to optimize FRI threshold and the minimal number of abnormal segments per vascular territory (LAD and non-LAD), required for automated detection of stress-induced perfusion defects. The optimized detection algorithm was then tested prospectively in the remaining 17 patients (Test group). LAD and non-LAD stenosis >70% was found in 19 and 17 patients, respectively. In the Study group, FRI threshold was: LAD=0.95 and non-LAD=0.68, minimal number of abnormal segments was four and two, correspondingly. Sensitivity, specificity and accuracy in the Test group were: 75%, 67% and 71% in the LAD, and 75%, 75% and 75% in the non-LAD territories. CONCLUSION: Automated quantitative analysis of contrast echocardiographic parametric perfusion images is feasible and may aid in the objective detection of CAD.

Aged↗

The research grant process: a reference guide for cardiovascular sonographers.

Opportunities for sonographer-initiated research have increased during the past decade. Although research has traditionally been viewed as a nonclinical activity, funding is available for clinical problems. This article aims to increase sonographer awareness of this unique opportunity, encourage the submission of grant proposals, and enhance the understanding of the grant writing process. This review discusses the procedures involved in planning a research project while describing the structure of the research grant proposal including specific aims, background, preliminary studies, methods, potential limitations, significance, budget, and references.

Echocardiography↗

Dual triggering improves the accuracy of left ventricular volume measurements by contrast-enhanced real-time 3-dimensional echocardiography.

Real-time 3-dimensional echocardiographic continuous imaging (CIM) with contrast underestimates left ventricular (LV) volumes. We studied the effects of dual-triggered (DT) acquisition on the accuracy of LV volume measurements for patients with poor acoustic windows. Real-time 3-dimensional echocardiographic imaging was performed in 20 patients during LV opacification (Definity) on the same day as cardiac magnetic resonance imaging. Both CIM and DT data were analyzed using custom software to calculate end-systolic volume (ESV) and end-diastolic volume (EDV), which were compared with the cardiac magnetic resonance reference. CIM correlated well with the cardiac magnetic resonance reference (EDV: r = 0.89; ESV: r = 0.93), but underestimated EDV and ESV by 17% and 19%, respectively. In contrast, DT resulted in higher correlation (EDV: r = 0.95; ESV: r = 0.96) and smaller biases (9% and 6%, respectively). In conclusion, because the accuracy of LV volume measurements depends on the acquisition strategy of contrast-enhanced real-time 3-dimensional echocardiographic images, the use of DT instead of the conventional CIM acquisition is recommended.

Computer Systems↗