PubMed Health⌕ Search

Biomedical subjects

Patrick Tchou

Publications and source records attributed to Patrick Tchou.

At least 19 recordsLinked to original sources

Pulmonary vein total occlusion following catheter ablation for atrial fibrillation: clinical implications after long-term follow-up.

OBJECTIVES: We present the clinical course and management outcomes of patients with total pulmonary vein occlusion (PVO). BACKGROUND: Pulmonary vein occlusion is a rare complication that can develop after radiofrequency catheter ablation (RFA) of atrial fibrillation (AF). The long term follow-up data of patients diagnosed with PVO are minimal. METHODS: Data from 18 patients with complete occlusion of at least one pulmonary vein (PV) were prospectively collected. All patients underwent RFA for AF using different strategies between September 1999 and May 2004. Pulmonary vein occlusion was diagnosed using computed tomography (CT) and later confirmed by angiography when intervention was warranted. Lung perfusion scans were performed on all patients before and after intervention. The percent stenoses of the veins draining each independent lung were added together to yield an average cumulative stenosis of the vascular cross-sectional area draining the affected lung (cumulative stenosis index [CSI]). RESULTS: The patients' symptoms had a positive correlation with the CSI (r = 0.843, p < 0.05) and a negative one with the lung perfusion (r = -0.667, p < 0.05). A CSI > or =75% correlated well with low lung perfusion (<25%; r = -0.854, p < 0.01). Patients with a CSI > or =75% appeared to improve mostly when early (r = -0.497) and repeat dilation/stenting (r = 0.0765) were performed. CONCLUSIONS: Patients with single PVO are mostly asymptomatic and should undergo routine imaging. On the other hand, patients with concomitant ipsilateral PV stenosis/PVO and a CSI > or =75% require early and, when necessary, repeated pulmonary interventions for restoration of pulmonary flow and prevention of associated lung disease.

Atrial Fibrillation↗

Electrical storm in patients with an implantable defibrillator: incidence, features, and preventive therapy: insights from a randomized trial.

AIMS: The purpose of this study was to assess the incidence, features, and clinical sequelae of 'electrical storm' (ES). METHODS AND RESULTS: This study is a prospectively designed secondary analysis of SHIELD; a randomized trial of azimilide for suppression of ventricular tachycardia/fibrillation (VT/VF) leading to implanted cardioverter defibrillator (ICD) therapies. Systematic and rigorous follow-up and blinded adjudication of ICD therapy allowed identification of all ESs (>/=3 separate VT/VF episodes leading to ICD therapies within 24 h). Of 633 ICD recipients, 148 (23%) experienced at least one ES over 1-year follow-up. No clinical predictors of ES were identified. Frequent VT episodes accounted for 91% of all ESs, with the remaining being VF alone or both VT plus VF. ES led to a 3.1-fold increase in arrhythmia-related hospitalization (95% CI 2.3-4.3; P<0.0001) compared with patients with isolated VT/VF, and to a 10.2-fold increase (95% CI 6.4-16.3; P<0.0001) compared with patients without VT/VF. Compared with placebo, azimilide (75 and 125 mg/day) reduced the risk of recurrent ES by 37% (HR=0.63, 95% CI 0.35-1.11, P=0.11) and 55% (HR=0.45, 95% CI 0.23-0.87, P=0.018), respectively. However, the reduction in time-to-first ES did not reach statistical significance by both doses (75 and 125 mg) of azimilide (HR=0.82, 95% CI 0.56-1.19, P=0.29 and HR=0.69, 95% CI 0.46-1.04, P=0.07), respectively. CONCLUSION: ES is common and unpredictable in ICD recipients and it is a strong predictor of hospitalization.

Anti-Arrhythmia Agents↗

Usefulness of atrioventricular delay optimization using Doppler assessment of mitral inflow in patients undergoing cardiac resynchronization therapy.

This study evaluated the utility of atrioventricular (AV) optimization using Doppler echocardiography in patients who undergo cardiac resynchronization therapy (CRT). AV optimization in patients who undergo CRT is performed inconsistently, with few data supporting its utility. Data were collected from 215 patients in New York Heart Association class III or IV heart failure (66% ischemic) who underwent AV optimization <30 days after implantation from 1999 to 2003. All patients arrived with AV delay programmed at the time of their CRT procedures (100 to 120 ms). AV delay was optimized using Doppler mitral inflow data to target stage I diastolic filling. Baseline clinical characteristics, AV delay, and diastolic functional stage were recorded. The mean follow-up period was 23 months. Five hundred patients underwent CRT, 215 of whom underwent AV optimization <30 days after implantation. Baseline mean age was 66 +/- 12 years, left ventricular (LV) ejection fraction 19 +/- 8%, LV end-diastolic dimension 6.5 +/- 1 cm, LV end-systolic dimension 5.5 +/- 1 cm, QRS duration 166 +/- 27 ms, and time to AV optimization 2.5 +/- 4 days. Baseline and final AV delay means were 120 +/- 25 and 135 +/- 40 ms, respectively (p = 0.0001). In 40% of patients (86 of 215), final AV delay settings were >140 ms. Left atrial diameter and AV block predicted patients in whom AV delay settings >140 ms were optimal. There was no difference in mortality in patients with final AV delays of >140 ms. In conclusion, AV optimization in patients who underwent CRT resulted in final AV delay settings of >140 ms in 40% of patients. AV delay optimization based on Doppler echocardiographic determination of optimal diastolic filling is useful and safe in patients who undergo CRT.

Aged↗

Phrenic nerve injury after catheter ablation: should we worry about this complication?

INTRODUCTION: Phrenic nerve injury (PNI) is a complication that can occur with catheter ablation. METHODS: Data from 17 patients with PNI following different catheter ablation techniques were reviewed. PNI was defined as decreased motility (transient) or paralysis (persistent) of the hemi-diaphragm on fluoroscopy or chest X-ray. Patient's recovery was monitored. Normalization of chest images and sniff test would be considered as complete clinical recovery. RESULTS: Out of the 17 PNI patients (16 right, 1 left), 13 (11 persistent, 2 transient) occurred after pulmonary veins isolation with or without superior vena cava ablation. Three patients had persistent PNI after sinus node modification and one other patient experienced PNI after epicardial ventricular tachycardia ablation. Ablation was performed with different energy source including radiofrequency (n = 13), cryothermal (n = 1), ultrasound (n = 2) and laser (n = 1). Patient's symptoms varied broadly from asymptomatic to dyspnea, and even to respiratory insufficiency that required temporary mechanical ventilation support. Two patients with transient PNI resolved immediately after the procedure and the other 15 persistent PNI patients resolved within a mean time of 8.3 +/- 6.6 months. CONCLUSIONS: PNI caused by catheter ablation appears to functionally recover over time regardless of the energy sources used for the procedure.

Adult↗

Intraoperative electro-anatomical mapping and beating heart ablation of ventricular tachycardia.

In most cases ventricular tachycardia is responsive to antiarrhythmic drug therapy. If antiarrhythmic drugs fail, then percutaneous, endocardial ablation guided by electro-anatomical mapping is usually curative. Occasionally neither of these therapies is successful and surgical ablation is required. Challenges encountered in surgical ablation include application of reliable intraoperative real-time electro-anatomical mapping to identify the focus of ventricular tachycardia and the need for technology that enables ablation on the beating heart. We present a case demonstrating the feasibility of surgical cryoablation of ventricular tachycardia arising from the right ventricle using intraoperative real-time epicardial and endocardial electro-anatomical mapping and argon-based cryoablation.

Bundle-Branch Block↗

Safety and efficacy of radiofrequency energy catheter ablation of atrial fibrillation in patients with pacemakers and implantable cardiac defibrillators.

BACKGROUND: Catheter ablation has significantly transformed the clinical management of atrial fibrillation (AF). The safety and efficacy of this procedure are not well understood in patients with pacemakers and defibrillators. OBJECTIVES: The purpose of this study was to study the impact of radiofrequency catheter ablation of AF in patients with pacemakers and implantable cardiac defibrillators. METHODS: We studied 86 patients with pacemakers and defibrillators (group I) and a similar number of age- and gender-matched controls (group II) who underwent AF ablation between 1999 and 2004. Clinical and procedural variables were compared between the two groups. In group I, various generator and lead parameters were compared before and after the procedure. Resurgence of clinical AF after 2 months was considered recurrence. RESULTS: Both groups were similar with regard to age, gender, body mass index, and type of AF. Group I had a higher incidence of diabetes (17% vs 6%, P = .03), coronary artery disease (25% vs 13%, P = .05), less prolonged AF (31 +/- 21 vs 45 +/- 30 months, P <.001), lower left ventricular ejection fraction (49 +/- 13% vs 52 +/- 9%, P = .03), and left ventricular end-diastolic dimensions (4.97 +/- 0.81 vs 4.72 +/- 0.67, P = .03). No changes in the sensing and pacing thresholds, impedance of atrial and ventricular leads, or defibrillator coil impedance after AF ablation were observed in group I. Atrial lead dislodgment was seen in two patients. Transient abnormal but "expected" pulse generator behavior was seen in 25% of patients without permanent malfunction. Stroke (1% vs 1%, P = 1.000), pulmonary vein stenosis (2% vs 1%, P = .77), and AF recurrence rates at 12 months were similar between groups I and II, respectively (19% vs 21%, P = .73). CONCLUSION: AF ablation is safe and efficacious in patients with pacemakers and defibrillators.

Atrial Fibrillation↗

The impact of povidone-iodine pocket irrigation use on pacemaker and defibrillator infections.

BACKGROUND: Infection is a devastating complication of permanent pacemakers (PMs) implantable cardioverter defibrillators (ICDs). Many implanting physicians commonly use povidone-iodine solution to irrigate the device pocket before implanting the device. We sought to assess if such a measure would alter the rate of infection. METHODS: A total of 2,564 consecutive patients who received implantable PM or ICD devices between 1994 and 2002 were studied. Povidone-iodine was used for pocket irrigation in 53% and saline in 47%. A total of 18 (0.7%) patients developed pocket infections with 0.7% (10/1,359) in povidone-iodine (group I) and 0.6% (8/1,205) in saline (group II) pocket irrigation (p = ns). Groups I and II were studied for various clinical and demographic variables described in the results section. RESULTS: There was no statistical difference in the baseline demographic and clinical characteristics between groups I and II, respectively. ICDs were most frequently infected than PMs (56% vs 44%). Most (83%) of the devices were dual chamber. Reopening of the pocket for either lead or generator replacement had a higher incidence of infection than new implants (61% vs 39%). There was no difference in the use of preimplantation antibiotic prophylaxis. Late (61%) and deep pocket infections (78%) were more common than early (39%) and superficial infections (22%). Blood cultures were positive in 67% and Staphylococcus aureus was the common most pathogen (50%). The mean duration of antibiotics use after the diagnosis of device infection was 35 +/- 23 days with 72% requiring device explantation. The device was reimplanted on the contralateral side in 56% cases. One patient in each group died due to device infection and related complications. No significant allergy to iodine was seen in either group. CONCLUSION: Povidone-iodine irrigation of the subcutaneous pocket did not alter the rates of pocket infection after pacemaker/defibrillator implantation.

Aged↗

The role of swab and tissue culture in the diagnosis of implantable cardiac device infection.

BACKGROUND: The isolation of a pathogen is vital in the diagnosis and treatment of a device infection. A swab culture, despite poor sensitivity, is the most common method used in specimen collection. OBJECTIVE: To determine the relative value of swab and tissue specimen cultures in patients with implantable cardiac pacemakers and defibrillators. DESIGN: Prospective patient cohort study. SETTING: A 1,000-bed tertiary referral center in Cleveland, Ohio. PATIENTS: Consecutive patients with implantable cardiac pacemaker or defibrillator presenting for lead extraction from October 1, 2000 to March 31, 2001. METHODS: Tissue and swab cultures were prospectively collected during pacemaker and implantable defibrillator surgeries that required lead extraction. Clinical manifestations, microbiology, and echocardiographic data were recorded in patients with and without a clinical diagnosis of device system infection. RESULTS: Seventy-one patients with implantable pacemaker (n = 49, 69%), implantable defibrillator (n = 18, 25%), or both devices (n = 4, 6%) requiring lead extraction had pocket swab and tissue cultures for analysis. Infection was evident clinically in 35 (49%) of the patients and absent in the remainder. The most common bacteria isolated were coagulase-negative Staphylococcus (37%) and Staphylococcus aureus (10%). Patients with clinical infection had positive cultures more frequently (P = 0.002) by pocket tissue culture (n = 24, 69%) than by swab culture (n = 11, 31%). However, patients without clinical infections had positive cultures at similar rates by pocket tissue culture (n = 10, 28%) and by swab culture (n = 8, 22%; P = 0.48). Patients without clinical infection were not treated with other than perioperative antibiotics, and did not develop clinical infections. CONCLUSION: Pocket tissue cultures are more effective than pocket swab cultures for the isolation and identification of the infectious pathogens in cardiac device infections. Positive cultures by pocket swab or tissue cultures in the absence of clinical signs and symptoms of infection does not imply infection or the need for specific therapy.

Aged↗

Azimilide decreases recurrent ventricular tachyarrhythmias in patients with implantable cardioverter defibrillators.

OBJECTIVES: This study evaluated the effects of azimilide dihydrochloride (AZ) on anti-tachycardia pacing (ATP) and shock-terminated events in patients with implantable cardioverter defibrillators (ICDs). BACKGROUND: Animal studies have shown the effectiveness of AZ for therapy of supraventricular and ventricular tachycardia (VT). Azimilide dihydrochloride was investigated as adjunctive treatment for reducing the frequency of VT and, thus, the need for ICD therapies, including ATP and cardioversion/defibrillation (ICD shocks) in patients with inducible monomorphic VT. METHODS: A total of 172 patients were randomized to daily treatment with placebo, 35 mg, 75 mg, or 125 mg of oral AZ in this dose-ranging pilot study of patients with ICDs. The majority of patients had a history of documented remote myocardial infarction and congestive heart failure New York Heart Association class II or III. RESULTS: The frequency of appropriate shocks and ATP were significantly decreased among AZ-treated patients compared with placebo patients. The incidence of ICD therapies per patient-year among the placebo group was 36, and it was 10, 12, and 9 among 35 mg, 75 mg, and 125 mg AZ patients, respectively (hazard ratio = 0.31, p = 0.0001). Azimilide dihydrochloride was generally well tolerated and did not affect left ventricular ejection fraction or minimal energy requirements for defibrillation or pacing. CONCLUSIONS: Azimilide dihydrochloride may be a safe and effective drug for reducing the frequency of VT and ventricular fibrillation in patients with implanted ICDs.

Aged↗

Pulmonary vein isolation for atrial fibrillation in patients with symptomatic sinus bradycardia or pauses.

INTRODUCTION: Sick sinus syndrome is commonly associated with tachyarrhythmias and bradyarrhythmias that often are symptomatic. The aim of this study was to assess the effect of pulmonary vein isolation in patients with sick sinus syndrome and atrial fibrillation (AF). METHODS AND RESULTS: Three hundred fourteen consecutive patients who underwent pulmonary vein isolation between December 2000 and January 2002 were included in the study. Thirty-one patients had sick sinus syndrome, which was defined as a preprocedural history of symptomatic sinus bradycardia or pauses. Endpoints included AF recurrence, change in the frequency of sinus pauses, and symptoms of presyncope or syncope, as well as mean heart rate and percentage of atrial pacing in patients with pacemakers implanted prior to the pulmonary vein isolation. Patients had AF for an average of 6 +/- 3 years. Patients were 58 +/-8 years old and had ejection fractions of 55 +/- 4%. Sixty-one percent had implanted pacemakers. AF recurred within 6 months in 4 patients. Two had a successful second pulmonary vein isolation procedure. There were no recurrences of presyncopal events (P < 0.05) or documented sinus pauses (P < 0.05) after successful pulmonary vein isolation in the patients without permanent pacemakers. Patients with pacemakers had a 13-fold reduction in the percentage of atrial pacing (P < 0.05). Both groups showed a significant increase in average heart rates at 6-month follow-up. CONCLUSION: Cure of AF by pulmonary vein isolation helped resolve the clinical manifestations of sick sinus syndrome, suggesting that the occurrence of AF and/or the associated treatment could be partially responsible for sick sinus syndrome.

Analysis of Variance↗

Use of a wearable defibrillator in terminating tachyarrhythmias in patients at high risk for sudden death: results of the WEARIT/BIROAD.

The automatic ICD improves survival in patients with a history of sudden cardiac arrest. However, some patients do not meet the guidelines for ICD implantation or are unable to receive an implantable device. This study tested the hypothesis that these patients could benefit from a wearable cardioverter defibrillator. Patients with symptomatic heart failure and an ejection fraction of <0.30 (WEARIT Study) or patients having complications associated with high risk for sudden death after a myocardial infarction or bypass surgery not receiving an ICD for up to 4 months (BIROAD Study) were enrolled into two studies. After a total of 289 patients had been enrolled in the trial (177 in WEARIT and 112 in BIROAD), prespecified safety and effectiveness guidelines had been met. Six (75%) of eight defibrillation attempts were successful. Six inappropriate shock episodes occurred during 901 months of patient use (0.67% unnecessary shocks per month of use). Twelve deaths occurred during the study 6 sudden deaths: 5 not wearing and 1 incorrectly wearing the device). Most patients tolerated the device although 68 patients quit due to comfort issues or adverse reactions. The results of the present study suggest that a wearable defibrillator is beneficial in detecting and effectively treating ventricular tachyarrhythmias in patients at high risk for sudden death who are not clear candidates for an ICD and may be useful as a bridge to transplantation or ICD in some patients.

Death, Sudden, Cardiac↗

Phased-array intracardiac echocardiography monitoring during pulmonary vein isolation in patients with atrial fibrillation: impact on outcome and complications.

BACKGROUND: The objective of this study was to assess the impact of intracardiac echocardiography (ICE) on the long-term success and complications in patients undergoing pulmonary vein isolation (PVI) for treatment of atrial fibrillation (AF). METHODS AND RESULTS: Three hundred fifteen patients underwent PVI for treatment of AF. Each patient underwent ostial isolation of all PVs using a cooled-tip ablation catheter. PVI was performed using circular mapping (CM) alone (group 1, 56 patients), CM and ICE (group 2, 107 patients), and CM and ICE with titration of radiofrequency energy based on visualization of microbubbles by ICE (group 3, 152 patients). After a mean follow-up time of 417+/-145 days, 19.6% (11 of 56), 16.8% (18 of 107), and 9.8% (15 of 152) of patients in groups 1, 2, and 3 experienced recurrence of AF, respectively. Moreover, whereas no group 3 patient experienced severe (>70%) PV stenosis, severe PV stenosis was documented in 3 (3.5%) of 56 patients in group 1 and in 2 (1.8%) of 107 patients in group 2 (P<0.05). No embolic events were detected in group 3 patients. CONCLUSIONS: Intracardiac echocardiography improves the outcome of cooled-tip PVI. Power adjustment guided by direct visualization of microbubble formation reduces the risk of PV stenosis and improves long-term cure.

Atrial Fibrillation↗

Use of different catheter ablation technologies for treatment of typical atrial flutter: acute results and long-term follow-up.

OBJECTIVES: We report the acute success and long-term follow-up in consecutive patients undergoing catheter ablation of typical right atrial flutter (AFL) using different ablation technologies. METHODS: One hundred and two patients presenting for treatment of AFL to our laboratory were included in the study. Based on availability and physician preference, ablation was performed with either a cooled-tip catheter (39 patients, group I), an 8- or 10-mm tip catheter connected to a high-power radiofrequency (RF) generator (25 patients, group II), or a 4- or 5-mm tip catheter (38 patients, group III). Acute ablation success was achieved in all group II and group III patients. Among the 38 patients undergoing ablation with the conventional catheter tip (group I), crossover to an 8-mm tip or a cooled tip ablation catheter was required in 11 patients (29%). The mean fluoroscopy time was significantly higher in group I (54.3 +/- 26.4 minutes) when compared to group II (39.6 +/- 19.6 minutes; P < 0.05) and group III (40 +/- 16 minutes; P = 0.0.5). After a mean follow up of 20 +/- 5 months no patient in group II experienced recurrence of AFL, whereas 18.4% (7 of 38 patients; P < 0.05) in group I and 10% (4 of 39 patients; P < 0.05) in group III had recurrence of AFL. Ablation technologies designed to obtain larger size lesions appeared to be more effective in achieving acute ablation success of AFL and in limiting the long-term recurrence rate of this arrhythmia.

Atrial Flutter↗

Evidence of specialized conduction cells in human pulmonary veins of patients with atrial fibrillation.

UNLABELLED: Specialized Conducting Cells in Human PV. INTRODUCTION: Depolarizations similar to those from the sinus node have been documented from the pulmonary veins after isolation procedures. We assessed the hypothesis that sinus node-like tissue is present in the pulmonary veins of humans. METHODS AND RESULTS: Pulmonary vein tissue was obtained from five autopsies (four individuals with a history of atrial fibrillation and one without a history of atrial arrhythmias) and five transplant heart donors. Autopsy veins were fixed in formaldehyde and processed for light microscopy to identify areas having possible conductive-like tissue. Areas requiring additional study were extracted from paraffin blocks and reprocessed for electron microscopy. Donor specimens were fixed in formaldehyde for histologic sections and glutaraldehyde for electron microscopy. Myocardial cells with pale cytoplasm were identified by light microscopy in 4 of the 5 autopsy subjects. Electron microscopy confirmed the presence of P cells, transitional cells, and Purkinje cells in the pulmonary veins of these cases. CONCLUSION: Our report is the first to show the presence of P cells, transitional cells, and Purkinje cells in human pulmonary veins. Whether these cells are relevant in the genesis of atrial fibrillation requires further study.

Adolescent↗

Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation: impact of different catheter technologies.

OBJECTIVES: We conducted this study to compare the efficacy and safety of different catheter ablation technologies and of distal versus ostial pulmonary veins (PV) isolation using the circular mapping technique. BACKGROUND: Electrical isolation of the PVs in patients with atrial fibrillation (AF) remains a technical challenge. METHODS: Two hundred eleven patients (163 men; mean age 53 +/- 11 years) with symptomatic AF were included in this study. In the first 21 patients (group 1), distal isolation (> or = 5 mm from the ostium) was achieved targeting veins triggering AF. In the remaining 190 patients (group 2), ostial isolation of all PVs was performed using 4-mm tip (47 patients), 8-mm tip (21 patients), or cooled-tip (122 patients) ablation catheters. RESULTS: Distal isolation was able to eliminate premature atrial contractions (PACs) and AF in six of 21 patients (29%) and 10 of 34 PVs. After a mean follow-up time of 6 +/- 4 months, no patients treated with the 8-mm tip catheter experienced recurrence of AF, whereas 21% (10 of 47 patients) and 15% (18 of 122 patients) of the patients ablated with the 4-mm tip and the cooled-tip ablation catheters experienced recurrence of AF after a mean follow-up of 10 +/- 3 and 4 +/- 2 months, respectively. Significant complications including stroke, tamponade, and severe stenosis occurred in 3.5% (8/211) of patients. CONCLUSIONS: Catheter technologies designed to achieve better lesion size appeared to have a positive impact on procedure time, fluoroscopy time, number of lesions, and overall efficacy. Although distal isolation can be achieved with fewer lesions, ostial isolation is required in the majority of patients to eliminate arrhythmogenic PACs and AF.

Adult↗

Three-dimensional nonfluoroscopic mapping and ablation of inappropriate sinus tachycardia. Procedural strategies and long-term outcome.

OBJECTIVES: We conducted this study to assess long-term results of three-dimensional (3-D) mapping-guided radiofrequency ablation (RFA) of inappropriate sinus tachycardia (IST). Change in activation after the administration of esmolol was also assessed and compared to the shift documented with successful sinus node (SN) modification. BACKGROUND: The long-term results after RFA of IST have been reported to vary between 27% and 66%. METHODS: Thirty-nine patients (35 women, mean age 31 +/- 9 years) with debilitating IST were included in the study. The area around the earliest site of activation recorded using the 3-D mapping system was targeted for ablation. The shift in the earliest activation site after administration of esmolol was compared with the shift after RFA. RESULTS: The heart rate at rest and in drug-free state ranged between 95 and 125 beats/min (mean 99 +/- 14 beats/min). Sinus node was successfully modified in all patients. Following ablation, the mean heart rate dropped to 72 +/- 8 beats/min, p < 0.01. The extent of the 3-D shift in caudal activation along the crista terminalis was more pronounced after RFA than during esmolol administration (23 +/- 11 mm vs. 7 +/- 5 mm, respectively, p < 0.05). No patient required pacemaker implantation after a mean follow-up time of 32 +/- 9 months; 21% of patients experienced recurrence of IST and were successfully re-ablated. CONCLUSIONS: Three-dimensional electroanatomical mapping seems to facilitate and improve the ablation results of IST. The difference in caudal shift seen after esmolol administration and following SN modification suggests that adrenergic hypersensitivity is not the only mechanism responsible for the inappropriate behavior of the SN.

Adult↗