Matching approved "nondedicated" hardware to obtain biventricular pacing and defibrillation: feasibility and troubleshooting.

Biventricular ICDs may offer increased benefit for patients with severe congestive heart failure and ventricular arrhythmia. Currently there are no approved dedicated biventricular ICDs available. Twenty-one consecutive patients who had approved nondedicated hardware implanted for biventricular pacing and defibrillation were included in this study. All device therapies were evaluated using stored electrograms. During mean follow-up at 13 +/- 7 months, 8 (36%) patients had inappropriate shocks. Ventricular fibrillation therapy was delivered for slow ventricular tachycardia because of double counting in two patients. In one patient, AV nodal reentrant tachycardia below detection rate cut off triggered device therapy because of ventricular double counting. Sinus tachycardia or premature atrial contraction initiating AV conduction and ventricular double counting resulted in shocks in five patients. The number of shocks per patient ranged from 1 to 64. Two patients required transient disconnection of the LV lead and subsequent ICD generator replacement for premature battery depletion. Two patients required AV junction ablation and three needed slow pathway ablation. Two patients were treated by upgrading to a device that was capable of a higher atrial tracking rate. The patients with impaired AV conduction or constant ventricular pacing did not have inappropriate therapy for sinus tachycardia or supraventricular arrhythmia. Use of conventional nondedicated hardware for biventricular pacer/defibrillator is feasible but should be considered only in patients with poor AV node function or less likely to require antitachycardic therapy, to avoid ICD double counting of ventricular sensed events and consequent high incidence of inappropriate therapies.

Adult↗

Nonexcitatory stimulus delivery improves left ventricular function in hearts with left bundle branch block.

INTRODUCTION: Preliminary data in a heart failure animal model and isolated muscle preparation have suggested that nonexcitatory stimulation (NES) improves left ventricular (LV) function. METHODS AND RESULTS: We compared biventricular (BV) pacing with NES in an animal model with left bundle branch block (LBBB). The left bundle branch (LBB) was ablated in eight normal heart pigs and led to >50% increase in QRS duration (mean 100 +/- 15 msec). End-diastolic LV pressure, end-systolic LV pressure, LV pressure (LV dP/dtmax), aortic pulse pressure, and LV ejection fraction were measured before pre-LBB ablation and compared with post-LBB ablation (AAI pacing), BV pacing, NES delivery, and BV+NES. Moreover, to evaluate LV diastolic function, we measured the early (E wave) and late flows (A wave) through the mitral valve using spectral Doppler. Compared with post-LBB ablation, NES led to a significant increase in LV dP/dtmax (1,047 +/- 224 mmHg/sec vs 897 +/- 116 mmHg/sec; P < 0.05), LV ejection fraction (64% +/- 18% vs 49% +/- 17%; P < 0.05), and aortic pulse pressure (18 +/- 3.6 mmHg vs 16 +/- 2.8 mmHg; P < 0.05). Moreover, improvement in LV hemodynamic parameters was significantly higher during NES delivery when compared with BV pacing. No significant changes in E wave, A wave, and E/A were recorded during NES, NES+BV, and BV pacing. CONCLUSION: Our preliminary data demonstrate that NES is superior to BV pacing in improving LV function in an animal model with LBBB. Moreover, we demonstrated that NES does not affect transmitral valve flow and subsequently LV diastolic function.

Animals↗

Circumferential ultrasound ablation for pulmonary vein isolation: analysis of acute and chronic failures.

INTRODUCTION: In patients undergoing circumferential isolation of the pulmonary veins with an ultrasound ablation system, we analyzed the temperatures achieved while delivering circumferential ostial lesions in the pulmonary veins. We also reviewed the angiograms obtained during the procedure and identified anatomic variants that could be responsible for ineffective lesion formation. METHODS AND RESULTS: During the early clinical use in 33 patients, a total of 85 veins were ablated. A mean of 16.9 +/- 12.3 ablations were delivered per patient, and a mean of 6.7 ablations per vein were applied. Entry block was assessed by placing a deflectable octapolar or a circular catheter in the vein. The following anatomic characteristics and technical limitations were identified as possible reasons for ineffective energy delivery: (1) funnel-shaped ostium; (2) ostial diameter larger than the balloon diameter; (3) inability to deliver the catheter to the right inferior or other vein ostia; (4) ostial instability; (5) early branching of the vein; and (6) eccentric position of the ultrasound transducer in the vein. In patients with recurrence of atrial fibrillation, 40% of the ostial lesions reached a temperature >60 degrees C. However, in patients cured by the ablation, 64% of the ostial lesions reached a temperature >60 degrees C (P < 0.06). At least 12 of the 20 chronic recurrences could have been related to technical limitations of the first system. Duration of atrial fibrillation and eccentric deployment of the ultrasound transducer were more frequent in patients with recurrence of arrhythmias at follow-up. CONCLUSION: Ostial anatomy of the veins may affect delivery of ultrasound energy to achieve circumferential lesions. Energy delivery at the ostium with a temperature > 60 degrees C may be important to maximize success. Reconfiguration of the system to overcome the shortcomings identified in the initial experience could increase its performance.

Adult↗

Use of intracardiac echocardiography for prediction of chronic pulmonary vein stenosis after ablation of atrial fibrillation.

INTRODUCTION: Measurements of pulmonary vein (PV) flow with intracardiac echocardiography (ICE) immediately before and after PV isolation may be a useful method for predicting which patients will develop chronic PV stenosis. METHODS AND RESULTS: We assessed preablation and postablation flows in each of the four PVs using a phase-array ICE catheter in 95 patients (mean age 52 +/- 13) undergoing atrial fibrillation ablation. The ostium of each of the PVs was defined using angiography, electrical mapping, and ICE imaging. Ostial electrical isolation of all PVs was achieved using a 4-mm cooled-tip radiofrequency ablation catheter. Change in PV flow, when present, was examined as both an absolute value and as a percentage of the baseline flow. All patients underwent spiral computed tomography (CT) scans of the PVs 3 months after the procedure for detection of stenosis. The average preablation diastolic flows for the left superior, left inferior, right superior, and right inferior veins were 0.56, 0.54, 0.47, and 0.45 m/sec, respectively. These values increased to 0.74, 0.67, 0.58, and 0.59 m/sec postablation (P < 0.001). Of 380 PVs ablated, the CT scans revealed 2 (1%) with severe (>70%) stenosis, 13 (3%) with moderate (51%-70%) stenosis, and 62 (16%) with mild (< or = 50%) stenosis. The r value between flow and stenosis was only 0.09 (P = NS). CONCLUSION: Acute changes in PV flow immediately after ostial PV isolation do not appear to be a strong predictor of chronic PV stenosis.

Adult↗

Ventricular fibrillation: ablation of a trigger?

We report the case of a patient with recurrent ventricular fibrillation (VF) and no evidence of structural heart disease. VF was consistently initiated by a relatively early-coupled premature ventricular contraction with identical morphology on each occasion. Treatment with antiarrhythmic agents failed to suppress the arrhythmia. Electrophysiologic testing showed high-frequency potential at the earliest activation site, and radiofrequency ablation resulted in abolition of the ventricular ectopy with no further VF recurrence. Suppression of VF arising from focal triggers in patients with frequent ventricular ectopy and normal heart can be achieved with catheter ablation, but further studies are needed to evaluate the prevalence of such a mechanism.