Simplified mathematics for customized refractive surgery.

PURPOSE: To describe a simple mathematical approach to customized corneal refractive surgery or customized intraocular lens (IOL) design that allows "hypervision" and to investigate the accuracy limits. SETTING: University eye hospital, Mainz, Germany. METHODS: Corneal shape and at least 1 IOL surface are approximated by the well-known Cartesian conic section curves (ellipsoid, paraboloid, or hyperboloid). They are characterized by only 2 parameters, the vertex radius and the numerical eccentricity. Residual refraction errors for this approximation are calculated by numerical ray tracing. These errors can be displayed as a 2-dimensional refraction map across the pupil or by blurring the image of a Landolt ring superimposed on the retinal receptor grid, giving an overall impression of the visual outcome. RESULTS: If the eye is made emmetropic for paraxial rays and if the numerical eccentricities of the cornea and lens are appropriately fitted to each other, the residual refractive errors are small enough to allow hypervision. Visual acuity of at least 2.0 (20/10) appears to be possible, particularly for mesopic pupil diameters. However, customized optics may have limited application due to their sensitivity to misalignment errors such as decentrations or rotations. CONCLUSIONS: The mathematical approach described by Descartes 350 years ago is adequate to calculate hypervision optics for the human eye. The availability of suitable mathematical tools should, however, not be viewed with too much optimism as long as the accuracy of the implementation in surgical procedures is limited.

Cornea↗

Determining postoperative anterior chamber depth.

PURPOSE: To compare measured and calculated postoperative anterior chamber depths (ACDs). SETTING: Department of Ophthalmology and Institute of Medical Physics, University of Vienna, Vienna, Austria, and Department of Ophthalmology, University of Mainz, Mainz, Germany. METHODS: The postoperative ACD was measured in 189 pseudophakic eyes using a laboratory prototype of partial coherence interferometry (PCI). In 6 intraocular lens (IOL) groups, the mean ACD was calculated by ray tracing based on the best-known A-constants of the SRK formulas. In addition, for each IOL type, each measured ACD was compared with a value calculated using the individual spherical equivalent of the postoperative refraction. RESULTS: The measured and the calculated ACD values were close and did not show systematic differences. The ACD values obtained in the study, however, differed significantly from the values published by the IOL manufacturers. A comparison of the PCI-assessed ACDs and the calculated values using the postoperative refraction showed more scattered results for the refraction-based data, which was probably the result of higher measurement errors with the autorefractometer than with PCI. CONCLUSIONS: High-precision interferometry measurements and ray-tracing calculations confirmed each other. The resulting mean ACD values should be used instead of the manufacturers' values. The refractive outcome of cataract surgery can be improved by combining preoperative high-precision PCI biometry and numerical ray tracing for IOL power calculations.

Anterior Chamber↗