PubMed Health⌕ Search

Biomedical subjects

Paul Wisdom

Publications and source records attributed to Paul Wisdom.

3 recordsLinked to original sources

Does shear stress modulate both plaque progression and regression in the thoracic aorta? Human study using serial magnetic resonance imaging.

OBJECTIVES: The purpose of this study was to investigate the role of shear stress (SS) in plaque regression. BACKGROUND: A condition favorable to the development of atherosclerotic lesions is low oscillating SS. In the descending thoracic aorta, the relationship between plaque distribution and SS has never been characterized. The regression of plaque as the result of lipid-lowering therapy is associated with reverse atherogenic mechanisms. Therefore, we investigated the role of SS in plaque regression. Magnetic resonance imaging (MRI) provides a unique opportunity to noninvasively study morphology and hemodynamics. METHODS: Cross-sectional images of atherosclerotic plaques in the descending thoracic aorta of 10 asymptomatic, hypercholesteremic patients were acquired at baseline and 24 months after starting lipid-lowering therapy by using a black-blood sequence on a 1.5-T clinical MRI system (5 mm x 780 microm x 780 microm). Average wall thickness (WT) was derived per quadrant. The aorta was subdivided in segments 2 cm in length starting 1 cm from the aortic arch. RESULTS: Average WT decreased with increasing distance from the arch (3.0 +/- 0.7 mm vs. 2.5 +/- 0.3 mm; p < 0.05) and showed a helical pattern from the proximal to distal segments. Phase-contrast MRI was performed in the thoracic aorta of eight healthy volunteers to derive typical average SS distribution. Shear stress predicted the location of WT (r(2) = 0.29, p < 0.05) but did not predict plaque regression. The best predictor of plaque regression was baseline WT. CONCLUSIONS: Our data showing an association between WT and average low SS locations support the role of local hemodynamics in the development of atherosclerotic lesions in descending thoracic aorta. Furthermore, SS does not seem to be the major predictor for plaque regression by lipid-lowering interventions. Therefore, our data suggest that other mechanisms are involved in the lipid-reversal mechanism.

Adult↗

The importance of end-systole for optimal reconstruction protocol of coronary angiography with 16-slice multidetector computed tomography.

OBJECTIVES: Multidetector-row computed tomography coronary images are usually analyzed in mid-diastole (MD). Because of slow coronary motion also in end-systole (ES), we evaluated the impact on image quality of including ES images and defined an efficient reconstruction protocol. MATERIAL AND METHODS: In 50 coronary multidetector-row computed tomography studies, 9 reconstructions (at 10% increments of the RR interval) were graded for image quality. Multiple combinations of reconstructions were compared. RESULTS: MD (60-70% of the RR interval) offered the best image quality. In 44% patients, the best reconstruction for >or=1 coronary was found in ES (20-30%). Their heart rate was higher (68.2+/-9.9 bpm vs. 59.2+/-8.8 bpm, P=0.0014). Combining ES and MD consistently offered superior image quality and less nonevaluable vessels than even larger numbers of diastolic reconstructions alone. A combination of 2-3 reconstructions was most efficient. Adding more reconstructions did not significantly improve results. CONCLUSIONS: Combining ES and MD reconstructions reduces nonevaluable coronary arteries, particularly with higher heart rates. A protocol including 2-3 reconstructions is the most efficient.

Adolescent↗

Parallel and nonparallel simultaneous multislice black-blood double inversion recovery techniques for vessel wall imaging.

PURPOSE: To reduce long examination times of black-blood vessel wall imaging by acquiring multiple slices simultaneously and by using parallel acquisition techniques. MATERIALS AND METHODS: DIR-rapid acquisition with relaxation enhancement (RARE) techniques imaging up to 10 simultaneous slices per acquisition with single and multiple 180 degrees -reinversion pulses were developed. A slab-selective reinversion multislice DIR-RARE sequence incorporating generalized autocalibrating partially parallel acquisitions (GRAPPA) imaging was implemented. Four-channel and eight-channel carotid coils were built to test these sequences. A total of 11 subjects were studied. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) efficiency factor (SEF, SNR/unit time/slice) were measured from aortic images of three healthy subjects to determine optimal MR parameters. The DIR-RARE-GRAPPA sequence was run on aortas and carotid arteries of the five remaining healthy subjects and three atherosclerotic patients with optimal parameters (acquisition times 12-21 seconds). RESULTS: SEFs of slab-selective protocols were significantly higher than those of slice-selective protocols, and SEFs of DIR-RARE-GRAPPA protocols were significantly higher than corresponding non-GRAPPA protocols (P < 0.05). CNR was not significantly different for all imaging protocols. The DIR-RARE-GRAPPA multislice sequence showed 8.35-fold time improvement vs. single-slice DIR-2RARE sequence. CONCLUSION: Future MRI atherosclerotic plaque studies can be performed in substantially shorter times using these methods.

Adult↗