PubMed Health⌕ Search

Biomedical subjects

Peter Czermak

Publications and source records attributed to Peter Czermak.

6 recordsLinked to original sources

Experimental and modelling study of different process modes for retroviral production in a fixed bed reactor.

Pseudotype vectors are promising for gene transfer in many gene therapy approaches, however, low-vector concentration in batch cultures and high temperature-dependent decay do limit sufficiently large-scale production. To overcome these obstacles, the kinetic relations of cell growth and vector formation in different culture modes need to be understood. Effective optimisation of process modes is needed to achieve sufficient yields. Experimental and modelling studies were carried out in order to analyse the impact of different process modes such as perfusion, perfused fed-batch or repeated-batch on vector titer and productivity. Retroviral pseudotype vector, derived from the murine leukaemia virus carrying the HIV-1 envelop protein MLV (HIV-1) were produced using a 200 ml fixed bed reactor for high cell density cultivation on macroporous carriers. After starting the cultivation in batch mode, the reactor was either run in perfusion, perfused fed-batch or repeated-batch. A mathematical model of the bioreaction was developed on the basis of experimental data measured in culture dishes. The ability of the model to describe all different process modes of fixed-bed cultivation without additional fitting of the parameters was proven by three long-term cultivations for more than 400 h. The results of optimisation with the aid of the model, leads to the conclusion that perfusion with optimised harvest cycles and fed flows, result in a higher yield in comparison to batch or fed batch culture.

Animals↗

Murine leukemia virus clearance by flocculation and microfiltration.

Clearance of murine leukemia virus from CHO cell suspensions by flocculation and microfiltration was investigated. Murine leukemia virus is a retrovirus that is recommended by the U.S. Food and Drug Administration for validating clearance of retrovirus-like particles. Due to biosafety considerations, an amphotropic murine leukemia virus vector (A-MLV) that is incapable of self-replication was used. Further, A-MLV is incapable of infecting CHO cells, thus ensuring that infection of the CHO cells in the feed did not result in a reduced virus titer in the permeate. The virus vector contains the gene for the enhanced green fluorescent protein (EGFP) to facilitate assaying for infectious virus particles. The virus particles are 80-130 nm in size. The feed streams were flocculated using a cationic polyelectrolyte. Microfiltration was conducted using 0.1 and 0.65 microm pore size hollow fiber membranes. The level of virus clearance in the permeate was determined. For the 0.1 microm pore size membranes a 1,000-fold reduction in the virus titer in the permeate was observed for feed streams consisting of A-MLV, A-MLV plus flocculant, A-MLV plus CHO cells, and A-MLV plus flocculant and CHO cells. While the flocculant had little effect on the level of virus clearance in the permeate for 0.1 microm pore size membranes, it did lead to higher permeate fluxes for the CHO cell feed streams. Virus clearance experiments conducted with 0.65 microm pore size membranes indicate little clearance of A-MLV from the permeate in the absence of flocculant. However, in the presence of flocculant the level of virus clearance in the permeate was similar to that observed for 0.1 microm pore size membranes. The results obtained here indicate that significant clearance of A-MLV is possible during tangential flow microfiltration. Addition of a flocculant is essential if the membrane pore size is greater than the diameter of the virus particles. Flocculation of the feed stream leads to an increase in the permeate flux.

Animals↗

Densonucleosis virus purification by ion exchange membranes.

Preparative chromatography is widely used in the downstream purification of biopharmaceutical products. Replacement of resins by membranes as chromatographic supports, overcomes many of the limitations associated with resin-based chromatography such as high-pressure drops, slow processing rates due to pore diffusion and channeling of the feed through the bed. In particular, adsorptive membranes may be ideally suited for virus capture. Virus capture is critical in a number of applications. In gene therapy and vaccine production, large-scale purification of virus vectors is often essential. In the manufacture of biopharmaceuticals, validation of virus clearance is critical. Here results for purification of Aedes aegypti densonucleosis virus (AeDNV) using anion and cation exchange membranes are presented. AeDNV is a non-enveloped, single-stranded mosquito-specific parvovirus. Virus particles are around 20 nm in size. AeDNV could find potential applications in integrated vector-borne disease control programs. In addition, capture of parvovirus for validation of virus clearance in the manufacture of biopharmaceuticals is of commercial importance. By adjusting the pH of the feed stream, AeDNV particles may be adsorbed by both anion and cation exchange membranes. However, strongly basic anion exchange membranes were the most effective in adsorbing AeDNV particles. Adsorption and subsequent elution of AeDNV by anion exchange membranes leads to significant virus concentration. Dynamic and static capacities for anion exchange membranes were similar. Further, a sharp elution curve was obtained suggesting that pore diffusional resistances are insignificant. The adsorption of AeDNV particles by anion exchange membranes may be described by a linear isotherm.

Chromatography, Ion Exchange↗

Experimental study of a ceramic microsparging aeration system in a pilot-scale animal cell culture.

The oxygen supply of cell cultures with the aid of free gas bubbles is an efficient process strategy in pharmaceutical production. If the cell-damaging impact of gas bubbles is reduced, direct aeration becomes a practical solution with scale-up potential and comparatively high oxygen transfer rates. In this paper a microsparging aeration system made of porous ceramic was compared with bubble-free membrane aeration. The sparging system was used for the long-term cultivation of mammalian cells in 2- to 100-L scale bioreactors and produced bubble sizes of 100-500 microm in diameter. Using a scale of 2.5 and 30 L, a cell density of 2.6 x 10(6) cells/mL was attained. When a 100-L scale was used, a density of 1.1 x 10(6) cells/mL was achieved, whereas a comparable membrane-aerated system showed a cell density of 2.2 x 10(6) cells/mL. At relatively low agitation rates of less than 70 rpm in the sparged bioreactors, a homogeneous and constant oxygen concentration was kept in the medium. As a result of the different foam-forming tendency caused by the lower gas flow of the ceramic sparger compared to that of the standard aeration systems, we were able to develop an appropriate process control strategy. Furthermore, oxygen transfer measurements for the common stainless steel sparger and the ceramic sparger showed a 3-fold higher oxygen transfer coefficient for the ceramic sparger.

Animals↗

Purification of densonucleosis virus by tangential flow ultrafiltration.

Purification at commercial scale of viruses and virus vectors for gene therapy applications and viral vaccines is a major separations challenge. Tangential flow ultrafiltration has been developed for protein purification. Here tangential flow ultrafiltration of parvoviruses has been investigated. Because these virus particles are small (18-26 nm), removal of host cell proteins will be challenging. The results obtained here indicate that 30, 50, and 100 kDa membranes reject the virus particles, whereas 300 kDa membranes allow some virus particles to pass into the permeate. The decrease in permeate flux for the 300 kDa ultrafiltration membrane is much greater than for the 30, 50, and 100 kDa membranes, indicating possible entrapment of virus particle in the membrane pores. The permeate flux and level of protein rejection is strongly affected by the cell culture growth medium. The results indicate that when developing a new process, it is essential that the cell culture and purification operations be developed in parallel.

Biotechnology↗

Accuracy of automated instruments used in the pharmaceutical industry for integrity testing sterilizing filters.

In the pharmaceutical industry, the integrity of sterile filters is critical to ensure sterility of filtered products. Filter integrity is frequently tested by measuring gas diffusion across water-contacting hydrophobic or hydrophilic membranes with the same automated test devices. Constant device accuracy over the whole range of possible operating conditions is an especially important requirement, as set by the GMP regulations for product critical devices. In this paper, we investigate the accuracy of gas diffusion rate and water intrusion rate estimates provided by a batch-operated and a refilling, continuous-flow commercial automated test device used both for diffusive flow tests and water intrusion tests. Tests were performed on custom-designed model filter systems and full-scale filters over a broad range of gas diffusive flow rates and upstream gas volumes. Neither tested device provided accurate measurements of gas diffusion rate when a small gas diffusion flow was measured out of a very large upstream volume. The batch-operated device provided measurements of gas diffusion rates (either gas diffusion or water intrusion rate) with an accuracy that strongly depends on the gas diffusion rate and on the gas volume upstream from the membrane. Gas diffusion rate measurements were particularly biased in diffusive flow tests of filters with less than 500 mL gas upstream volume. Gas diffusion rates were underestimated by as much as -14.5% in diffusive flow tests and -25% in water intrusion tests. The refilling, continuous flow device generally provided consistent and accurate gas diffusion rate and water intrusion rate measurements within less than 5% of the reference value, practically independent of the gas diffusion flow rate and upstream volume value. A serious bias was only noted in diffusion flow tests at very high upstream volumes and low gas diffusion rate. The results reported in this paper show the importance of qualifying the automated test devices used to assess sterile filter integrity.

Diffusion↗