PubMed Health⌕ Search

Biomedical subjects

Peter Fenici

Publications and source records attributed to Peter Fenici.

8 recordsLinked to original sources

The immediate life support (ILS) course--the Italian experience.

AIM OF THE STUDY: The 1-day immediate life support course (ILS) was started in the United Kingdom and adopted by the ERC to train healthcare professionals who attend cardiac arrests only occasionally. Currently, there are no reports about the ILS course from outside the UK. In this paper we describe our initial Italian experience of teaching ILS to nurses. We have also measured the impact that ILS has on the resuscitation knowledge of nurses. METHODS: The ILS course materials were translated by Italian ALS instructors who had observed the ILS course previously in the UK. From March to November 2005 nurses from a single hospital department attended the Italian ILS course. Candidate feedback was collected using an evaluation form. The change in knowledge of candidates was measured using a pre- and post-course test. Variables associated with candidate performance on course papers were investigated using multivariate linear regression analysis. RESULTS: A total of 119 nurses attended nine ILS courses. All candidates completed the course successfully and gave high evaluation scores. ILS produced a significant increase from pre- to post-course score (10.15+/-2.75 to 13.19+/-2.53, p<0.001). The pre-course score was higher for nurses working in ICU compared with those coming from non-intensive wards, but this difference disappeared in the post-course evaluation (13.89+/-2.18 versus 12.79+/-2.65, p=ns). CONCLUSIONS: We have reproduced the ILS course in Italy successfully. ILS teaching resulted in an improvement in resuscitation knowledge of the first group of nurses trained.

Adult↗

Haemodynamic effects of mental stress during cardiac arrest simulation testing on advanced life support courses.

UNLABELLED: We investigated the haemodynamic response to the mental stress induced by being evaluated as a team leader in simulated advanced life support (ALS) scenarios. METHODS: Healthcare providers participating as candidates to ALS courses were monitored while acting as team leaders in a cardiac arrest testing scenario (CASTest). Heart rate (HR), systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured before, during and after the CASTest. The correlation between the haemodynamic responses and sex, age, body mass index (BMI) and marks on course multiple choice questions (MCQs) were studied using multiple linear regression. RESULTS: Eighty-eight subjects (46 women, 42 men, mean age 34.9+/-6.8 years) were enrolled. Mean HR, SBP and DBP increased significantly during the CASTest and reached a peak after a phase of the scenario which included an unsuccessful defibrillation. Ten minutes after the CASTest, HR, SBP and DBP were still significantly higher than their respective baseline values. A significant positive correlation was found between the DBP and SBP response during the scenario and the BMI, and between the DBP response and the candidates' age. The haemodynamic stress response was neither correlated with the candidates' marks in the course MCQ nor with their instructor potential (IP). CONCLUSION: During the testing scenario the ALS candidates showed a significant haemodynamic response to mental stress, which depended mainly on their age and BMI rather than on their knowledge and skills.

Adult↗

What is the optimal chest compression-ventilation ratio?

PURPOSE OF REVIEW: Despite a more widespread knowledge of basic cardiopulmonary resuscitation maneuvers in the community, the survival rate for patients with cardiac arrest has remained essentially unchanged in the past 30 years. Over the past few decades, many different compression-ventilation ratios have been studied in terms of best coronary and cerebral oxygen delivery, restoration of spontaneous circulation, and neurologic outcome. This article summarizes the recent evidence presented at the International Consensus on Resuscitation Science in January 2005. RECENT FINDINGS: Recent data from animal and mathematical models suggest a move to a higher compression-ventilation ratio to maximize coronary and cerebral oxygen delivery during cardiac arrest and long-term neurologic outcome. Prospective randomized human data on alternative compression-ventilation ratios are missing and new evidence seems to indicate the inadequacy of both lay and professional rescuers in providing chest compression and ventilating the victim in cardiac arrest. Finally, observational and animal studies highlight the hidden danger of inadvertent hyperventilation during advanced cardiac life support as a reduction of both coronary and perfusion pressure secondary to increased intrathoracic pressure and decreased venous return. SUMMARY: The optimal compression-ventilation ratio is still unknown and the best tradeoff between oxygenation and organ perfusion during cardiopulmonary resuscitation is probably different for each patient and scenario. A discrepancy between what is recommended by the current guidelines and the 'real world' of cardiopulmonary resuscitation has resulted in a near flat survival rate from cardiac arrest in the past few years.

Cardiopulmonary Resuscitation↗

Automated external defibrillation by untrained deaf lay rescuers.

INTRODUCTION: The use of automated external defibrillators (AEDs) by lay rescuers can reduce the time to defibrillation, improving survival after out-of-hospital cardiac arrest. However, some people have hearing defects that can prevent them from understanding the AED verbal prompts. Moreover, even rescuers with normal hearing function may not easily understand the AED verbal prompts when operating in a noisy environment. This study was designed to assess the capability of rescuers to defibrillate effectively using an AED which included visual prompts. METHODS AND RESULTS: Nine deaf employees with no previous experience in basic life support (BLS) or defibrillation were asked to defibrillate a manikin following the text prompts of a Heartstart FR2+ AED. Subjects were tested before and after a 6 h BLS-AED course carried out with the help of a sign language interpreter. Before training, seven out of nine deaf subjects (78%) were able to defibrillate, eight out of nine subjects (89%) placed the pads correctly, and the mean time to defibrillation was 101.3 +/- 28.4 s. After the course, all subjects were able to complete the defibrillation sequence and place the pads correctly. The mean post-course time to defibrillation was 47.8 +/- 5.4 s (P < 0.001). None of the nine subjects touched the manikin during charging of the defibrillator and shock delivery before or after the course. CONCLUSIONS: This study demonstrates that untrained deaf rescuers can use AEDs appropriately providing that the defibrillator has visual instructions. Training improves defibrillator use and reduces time to defibrillation.

Cardiopulmonary Resuscitation↗

A survey of the in-hospital response to cardiac arrest on general wards in the hospitals of Rome.

OBJECTIVE: To investigate the response to cardiac arrest in general wards. METHODS: Direct interview with the cardiac arrest team (CAT) members in 32 hospitals in Rome, Italy. RESULTS: The majority of CATs are activated by telephone but only two (6%) hospitals have a dedicated telephone number for emergency calls. The CAT always includes a physician, who is usually an anaesthesiologist (30 hospitals, 94%), and usually includes one or two other members (23 hospitals, 72%). In 21 hospitals (65%) there is less than one defibrillator per floor but in only six hospitals (19%), CATs are equipped with defibrillators. Resuscitation guidelines are adopted by 15 teams (47%). The Utstein style of data collection is used in only one hospital. The most common problems reported by the CATs are: insufficient training of ward personnel (29 hospitals, 91%), insufficient staff (19 hospitals, 59%) and insufficient equipment (18 hospitals, 56%). Average maximum arrival time for the CAT to arrive is 220 s, but varies significantly between single-building and the multiple-building hospitals (88 vs. 390 s; P<0.001). CONCLUSIONS: The majority of the cardiac arrest teams have acceptable response times, but their efficiency may be impaired by the lack of staff, equipment and co-ordination with the ward personnel. CAT members identified a strong need for BLS training of ward personnel. More widespread introduction of standard protocols for resuscitation and reporting of cardiac arrest are necessary to evaluate aspects that may need improvement.

Data Collection↗

Phantom validation of multichannel magnetocardiography source localization.

Multichannel magnetocardiography (MMCG) is used clinically for noninvasive localization of the site of origin of cardiac arrhythmias. However, its accuracy in unshielded environments is still unknown. The aim of this study was to test the accuracy of three-dimensional localization of intracardiac sources by means of MMCG in an unshielded catheterization laboratory using a saline-filled phantom, together with a nonmagnetic catheter designed for multiple monophasic action potential recordings in a clinical setting. A nine-channel direct current superconducting quantum interference device (DC-SQUID) system (sensitivity fT/Hz0.5) was used for MMCG from 36 points in a measuring area of 20 x 20 cm. The artificial sources to be localized were dipoles embedded in the distal end of the catheter, placed 12 cm below the sensor's plane. Equivalent current dipoles, effective magnetic dipoles, and distributed currents models were used for the inverse solution. The localization error was estimated as the three-dimensional difference between the physical position of the tip of the catheter and the three-dimensional localization of the dipoles derived by means of the inverse solution calculated from MMCG data. The reproducibility was tested by repeating the MMCG after repositioning the phantom and the measurement system. The average location error of the catheter dipole was 9 +/- 4 mm and was due primarily to imprecise depth estimation. Localization was reproducible within 0.73 mm. The distributed currents model provided an accurate image of current distribution centered over the catheter tip. The authors conclude that MMCG estimation is accurate enough to guarantee proper localization of cardiac dipolar sources even in an unshielded clinical electrophysiological laboratory.

Arrhythmias, Cardiac↗

Noninvasive study of ventricular preexcitation using multichannel magnetocardiography.

In clinical practice, noninvasive classification of ventricular preexcitation (VPX) is usually done with ECG algorithms, which provide only a qualitative localization of accessory pathways. Since 1984, single or multichannel magnetocardiography (MMCG) has been used for three-dimensional localization of VPX sites, but a systematic study comparing the results of ECG and MMCG methods was lacking. This study evaluated the reliability of MMCG in an unshielded electrophysiological catheterization laboratory, and compared VPX classification as achieved with the five most recent ECG algorithms with that obtained by MMCG mapping and imaging techniques. A nine-channel direct current superconducting quantum interference device (DC-SQUID) MMCG system (sensitivity is 20 fT/Hz0.5) was used for sequential MMCG from 36 points on the anterior chest wall, within an area 20 x 20 cm. Twenty-eight patients with Wolff-Parkinson-White syndrome were examined at least twice, on the same day or after several months to test the reproducibility of the measurements. In eight patients, the reproducibility of MMCG was also evaluated using different MCG instrumentation during maximal VPX and/or atrioventricular reentrant tachycardia induced by transesophageal atrial pacing via a nonmagnetic catheter. The results of VPX localization with ECG algorithms and MMCG were compared. Equivalent current dipole, effective magnetic dipole, and distributed currents imaging models were used for the inverse solution. MMCG classification of VPX was found to be more accurate than ECG methods, and also provided additional information for the identification of paraseptal pathways. Furthermore, in patients with complex activation patterns during the delta wave, distributed currents imaging revealed two different activation patterns, suggesting the existence of multiple accessory pathways.

Algorithms↗