A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation.

RATIONALE AND OBJECTIVES: Duration of weaning from mechanical ventilation may be reduced by the use of a systematic approach. We assessed whether a closed-loop knowledge-based algorithm introduced in a ventilator to act as a computer-driven weaning protocol can improve patient outcomes as compared with usual care. METHODS AND MEASUREMENTS: We conducted a multicenter randomized controlled study with concealed allocation to compare usual care for weaning with computer-driven weaning. The computerized protocol included an automatic gradual reduction in pressure support, automatic performance of spontaneous breathing trials (SBT), and generation of an incentive message when an SBT was successfully passed. One hundred forty-four patients were enrolled before weaning initiation. They were randomly allocated to computer-driven weaning or to physician-controlled weaning according to local guidelines. Weaning duration until successful extubation and total duration of ventilation were the primary endpoints. MAIN RESULTS: Weaning duration was reduced in the computer-driven group from a median of 5 to 3 d (p=0.01) and total duration of mechanical ventilation from 12 to 7.5 d (p=0.003). Reintubation rate did not differ (23 vs. 16%, p=0.40). Computer-driven weaning also decreased median intensive care unit (ICU) stay duration from 15.5 to 12 d (p=0.02) and caused no adverse events. The amount of sedation did not differ between groups. In the usual care group, compliance to recommended modes and to SBT was estimated, respectively, at 96 and 51%. CONCLUSIONS: The specific computer-driven system used in this study can reduce mechanical ventilation duration and ICU length of stay, as compared with a physician-controlled weaning process.

Aged↗

Automatic adjustment of pressure support by a computer-driven knowledge-based system during noninvasive ventilation: a feasibility study.

OBJECTIVE: To evaluate the feasibility of using a knowledge-based system designed to automatically titrate pressure support (PS) to maintain the patient in a "respiratory comfort zone" during noninvasive ventilation (NIV) in patients with acute respiratory failure. DESIGN AND SETTING: Prospective crossover interventional study in an intensive care unit of a university hospital. PATIENTS: Twenty patients. INTERVENTIONS: After initial NIV setting and startup in conventional PS by the chest physiotherapist NIV was continued for 45 min with the automated PS activated. MEASUREMENTS AND RESULTS: During automated PS minute-volume was maintained constant while respiratory rate decreased significantly from its pre-NIV value (20+/-3 vs. 25+/-3 bpm). There was a trend towards a progressive lowering of dyspnea. In hypercapnic patients PaCO(2) decreased significantly from 61+/-9 to 51+/-2 mmHg, and pH increased significantly from 7.31+/-0.05 to 7.35+/-0.03. Automated PS was well tolerated. Two system malfunctions occurred prompting physiotherapist intervention. CONCLUSIONS: The results of this feasibility study suggest that the system can be used during NIV in patients with acute respiratory failure. Further studies should now determine whether it can improve patient-ventilator interaction and reduce caregiver workload.

Aged↗

Hospitalized mechanically ventilated patients are at higher risk of enteral underfeeding than non-ventilated patients.

BACKGROUND & AIMS: Enteral nutrition (EN) is the preferred method of nutrition support in hospitalized patients but only 50-90% of the required calories are actually delivered. In order to identify where our nutrition support team (NST) should focus its activity, we prospectively evaluated the level of coverage of energy and protein needs during the first 5 days of EN in intensive care unit (ICU) and non-ICU patients and the relationship of energy and protein coverage with serum albumin, transthryretin, insulin-like growth factor-1 (IGF-1) and C-reactive protein (CRP). METHODS: Subjects (n=183) who required nutrition support and received EN were prospectively recruited. Calorie prescription was 20 and 25, 25 and 30 kcal/kg BW for women and men 60 years and <60 years, respectively. Protein needs were estimated as 1.2g protein/kg BW. Logistic regression analysis was used to estimate odds ratios (OR) for energy and protein delivery 66.6% and <66.6% and albumin, transthryretin, IGF-1 (low vs. normal) and CRP (high vs. normal) in ventilated vs. non-ventilated patients. RESULTS: Significantly more mechanically ventilated than non-ventilated patients received <66.6% of energy (71% vs. 48%) and protein (96% vs. 65%). The ventilated patients were more likely to be energy (OR 2.1, CI 1.1-4.0) and protein (OR 15.7, CI 4.9-50.8) underfed than non-ventilated patients. There was a significant association on day 5 between low protein delivery and low albumin (OR 2.9, CI 1.3-6.5), low transthyretin (OR 3.0, CI 1.4-6.5), low IGF-1 (OR 2.8, CI 1.2-6.7) and high CRP (OR 3.5, CI 1.6-7.8). CONCLUSIONS: The energy and protein needs of hospitalized patients are not met during the first 5 days of EN. Ventilated patients are more likely to be energy and protein underfed than non-ventilated patients and to have low plasma protein level. These findings support our decision to intensify EN monitoring by our NST in ventilated patients to optimize their nutritional coverage.

Aged↗

Performance characteristics of five new anesthesia ventilators and four intensive care ventilators in pressure-support mode: a comparative bench study.

BACKGROUND: During the past few years, many manufacturers have introduced new modes of ventilation in anesthesia ventilators, especially partial-pressure modalities. The current bench test study was designed to compare triggering and pressurization of five new anesthesia ventilators with four intensive care unit ventilators. METHODS: Ventilators were connected to a two-compartment lung model. One compartment was driven by an intensive care unit ventilator to mimic "patient" inspiratory effort, whereas the other was connected to the tested ventilator. The settings of ventilators were positive end-expiratory pressures of 0 and 5 cm H2O, and pressure-support ventilation levels of 10, 15, and 20 cm H2O with normal and high "patient" inspiratory effort. For the anesthesia ventilators, all the measurements were obtained for a low (1 l/min) and a high (10 l/min) fresh gas flow. Triggering delay, triggering workload, and pressurization at 300 and 500 ms were analyzed. RESULTS: For the five tested anesthesia ventilators, the pressure-support ventilation modality functioned correctly. For inspiratory triggering, the three most recent anesthesia machines (Fabius, Drägerwerk AG, Lübeck, Germany; Primus, Drägerwerk AG; and Avance, GE-Datex-Ohemda, Munchen, Germany) had a triggering delay of less than 100 ms, which is considered clinically satisfactory and is comparable to intensive care unit machines. The use of positive end-expiratory pressure modified the quality of delivered pressure support for two anesthesia ventilators (Kion, Siemens AG, Munich, Germany; and Felix, Taema, Antony, France). Three of the five anesthesia ventilators exhibited pressure-support ventilation performance characteristics comparable to those of the intensive care unit machines. Increasing fresh gas flow (1 to 10 l/min) in the internal circuit did not influence the pressure-support ventilation performance of the anesthesia ventilators. CONCLUSION: Regarding trigger sensitivity and the system's ability to meet inspiratory flow during pressure-supported breaths, the most recent anesthesia ventilators have comparable performances of recent-generation intensive care unit ventilators.

Anesthesia, Inhalation↗

Clinical review: patient-ventilator interaction in chronic obstructive pulmonary disease.

Mechanically ventilated patients with chronic obstructive pulmonary disease often prove challenging to the clinician due to the complex pathophysiology of the disease and the high risk of patient-ventilator asynchrony. These problems are encountered in both intubated patients and those ventilated with noninvasive ventilation. Much knowledge has been gained over the years in our understanding of the mechanisms underlying the difficult interaction between these patients and the machines used to provide them with the ventilatory support they often require for prolonged periods. This paper attempts to summarize the various key issues of patient-ventilator interaction during pressure support ventilation, the most often used partial ventilatory support mode, and to draw clinicians' attention to the need for sufficient knowledge when setting the ventilator at the bedside, given the often conflicting goals that must be met.

Humans↗

Clinical evaluation of hormonal stress state in medical ICU patients: a prospective blinded observational study.

OBJECTIVE: To evaluate whether classification of patients as having low, moderate, or high stress based on clinical parameters is associated with plasma levels of stress hormone. DESIGN AND SETTING: Prospective, blinded, observational study in an 18-bed medical ICU. PATIENTS: Eighty-eight consecutive patients. INTERVENTIONS: Patients were classified as low (n=28), moderate (n=33) or high stress (n=27) on days 0 and 3 of ICU stay, based on 1 point for each abnormal parameter: body temperature, heart rate, systemic arterial pressure, respiratory rate, physical agitation, presence of infection and catecholamine administration. The stress categories were: high: 4 points or more, moderate 2-3 points, low 1 point. Plasma growth hormone (GH), insulin-like growth factor 1 (IGF-1), insulin, glucagon, cortisol were measured on days 0 and 3. MEASUREMENTS AND RESULTS: Plasma cortisol and glucagon were significantly higher and IGF-1 lower in high vs. low stress patients on days 0 and 3. High stress patients were more likely to have high cortisol levels (odds ratio 5.8, confidence interval 1.8-18.9), high glucagon (8.7, 2.1-36.1), and low IGF-1 levels (5.9, 1.8-19.0) than low stress patients on day 0. Moderate stress patients were also more likely to have high cortisol and glucagon levels than low stress patients. Insulin and GH did not differ significantly. Results were similar for day 3. CONCLUSIONS: Moderate and severe stress was significantly associated with high catabolic (cortisol, glucagon) and low anabolic (IGF-1) hormone levels. The hormonal stress level in ICU patients can be estimated from simple clinical parameters during routine clinical evaluation.

Adolescent↗

Helium-oxygen decreases inspiratory effort and work of breathing during pressure support in intubated patients with chronic obstructive pulmonary disease.

OBJECTIVE: To evaluate the impact of helium-oxygen (He/O2) on inspiratory effort and work of breathing (WOB) in intubated COPD patients ventilated with pressure support. DESIGN AND SETTING: Prospective crossover interventional study in the medical ICU of a university hospital. PATIENTS AND PARTICIPANTS: Ten patients. INTERVENTIONS: Sequential inhalation (30 min each) of three gas mixtures: (a) air/O2, (b) He/O2 (c) air/O2, at constant FIO2 and level of pressure support. MEASUREMENTS AND RESULTS: Inspiratory effort and WOB were determined by esophageal and gastric pressure. Throughout the study pressure support and FIO2 were 14+/-3 cmH2O and 0.33+/-0.07 respectively. Compared to Air/O2, He/O2 reduced the number of ineffective breaths (4+/-5 vs. 9+/-5 breaths/min), intrinsic PEEP (3.1+/-2 vs. 4.8+/-2 cmH2O), the magnitude of negative esophageal pressure swings (6.7+/-2 vs. 9.1+/-4.9 cmH2O), pressure-time product (42+/-37 vs. 67+/-65 cmH2O s(-1) min(-1)), and total WOB (11+/-3 vs. 18+/-10 J/min). Elastic (6+/-1 vs. 10+/-6 J/min) and resistive (5+/-1 vs. 9+/-4 J/min) components of the WOB were decreased by He/O2. CONCLUSIONS: In intubated COPD patients ventilated with pressure support He/O2 reduces intrinsic PEEP, the number of ineffective breaths, and the magnitude of inspiratory effort and WOB. He/O2 could prove useful in patients with high levels of PEEPi and WOB ventilated in pressure support, for example, during weaning.

Aged↗

Impact of expiratory trigger setting on delayed cycling and inspiratory muscle workload.

RATIONALE: During pressure-support ventilation, the ventilator cycles into expiration when inspiratory flow decreases to a given percentage of peak inspiratory flow ("expiratory trigger"). In obstructive disease, the slower rise and decrease of inspiratory flow entails delayed cycling, an increase in intrinsic positive end-expiratory pressure, and nontriggering breaths. OBJECTIVES: We hypothesized that setting expiratory trigger at a higher than usual percentage of peak inspiratory flow would attenuate the adverse effects of delayed cycling. METHODS: Ten intubated patients with obstructive disease undergoing pressure support were studied at expiratory trigger settings of 10, 25, 50, and 70% of peak inspiratory flow. MEASUREMENTS: Continuous recording of diaphragmatic EMG activity with surface electrodes, and esophageal and gastric pressures with a dual-balloon nasogastric tube. MAIN RESULTS: Compared with expiratory trigger 10, expiratory trigger 70 reduced the magnitude of delayed cycling (0.25 +/- 0.18 vs. 1.26 +/- 0.72 s, p < 0.05), intrinsic positive end-expiratory pressure (4.8 +/- 1.9 vs. 6.5 +/- 2.2 cm H(2)O, p < 0.05), nontriggering breaths (2 +/- 3 vs. 9 +/- 5 breaths/min, p < 0.05), and triggering pressure-time product (0.9 +/- 0.8 vs. 2.1 +/- 0.7 cm H2O . s, p < 0.05). CONCLUSIONS: Setting expiratory trigger at a higher percentage of peak inspiratory flow in patients with obstructive disease during pressure support improves patient-ventilator synchrony and reduces inspiratory muscle effort. Further studies should explore whether these effects can influence patient outcome.

Aged↗

Inhaled nitric oxide therapy in adults: European expert recommendations.

BACKGROUND: Inhaled nitric oxide (iNO) has been used for treatment of acute respiratory failure and pulmonary hypertension since 1991 in adult patients in the perioperative setting and in critical care. METHODS: This contribution assesses evidence for the use of iNO in this population as presented to a expert group jointly organised by the European Society of Intensive Care Medicine and the European Association of Cardiothoracic Anaesthesiologists. CONCLUSIONS: Expert recommendations on the use of iNO in adults were agreed on following presentation of the evidence at the expert meeting held in June 2004.

Administration, Inhalation↗

Non-invasive ventilation in the recovery room for postoperative respiratory failure: a feasibility study.

BACKGROUND: Non-invasive ventilation (NIV) has become a standard of care in acute respiratory failure. However, little data is available on its usefulness in recovery ward patients after general surgery. The present study aimed to document the feasibility of implementing NIV in this setting, and its impact on lung function. METHODS: During a 12-month period, all adult patients who underwent elective general surgical procedures under general anaesthesia during weekdays, were transferred to the recovery ward after extubation, and those who required NIV were included in this prospective observational study. NIV was applied with a bilevel device (VPAP II ST, ResMed, North Ryde, Australia). RESULTS: 4622 patients were admitted to the recovery ward, 83 of whom needed NIV. NIV increased pH (7.38 +/- .06 vs 7.30 +/- .05), reduced PaCO2 (7.38 +/- .06 vs 7.30 +/- .05) in hypercapnic patients (44 +/- 9 vs 55 +/- 10 mm Hg), and increased PaO2 in non-hypercapnic patients (80 +/- 10 vs 70 +/- 11 mm Hg). No complications attributable to NIV occurred. Most patients improved after 1-2 NIV trials, and all were transferred to the ward the same day. CONCLUSIONS: In recovery ward patients after general surgery, NIV is seldom required. When applied, NIV seems to exert favourable effects on lung function. NIV can be safely implemented with a bilevel device in a recovery ward not accustomed to the use of ICU ventilators. The cost-effectiveness of its systematic use in this setting should be assessed.

Aged↗

Performance characteristics of 10 home mechanical ventilators in pressure-support mode: a comparative bench study.

OBJECTIVE: Inspiratory pressure (Pi) support delivered by a bilevel device has become the technique of choice for noninvasive home ventilation. Considerable progress has been made in the performance and functionality of these devices. The present bench study was designed to compare the various characteristics of 10 recently developed bilevel Pi devices under different conditions of respiratory mechanics. DESIGN: Bench model study. SETTING: Research laboratory, university hospital. MEASUREMENTS: Ventilators were connected to a lung model, the mechanics of which were set to normal, restrictive, and obstructive, that was driven by an ICU ventilator to mimic patient effort. Pressure support levels of 10 and 15 cm H(2)O, and maximum were tested, with "patient" inspiratory efforts of 5, 10, 15, 20, and 25 cm H(2)O. Tests were conducted in the absence and presence of leaks in the system. Trigger delay, trigger-associated inspiratory workload, pressurization capabilities, and cycling were analyzed. RESULTS: All devices had very short trigger delays and triggering workload. Pressurization capability varied widely among the machines, with some bilevel devices lagging behind when faced with a high inspiratory demand. Cycling was usually not synchronous with patient inspiratory time when the default settings were used, but was considerably improved by modifying cycling settings, when that option was available. CONCLUSIONS: A better knowledge of the technical performance of bilevel devices (ie, pressurization capabilities and cycling profile) may prove to be useful in choosing the machine that is best suited for a patient's respiratory mechanics and inspiratory demand. Clinical algorithms to help set cycling criteria for improving patient-ventilator synchrony and patient comfort should now be developed.

Humans↗

Higher calorie prescription improves nutrient delivery during the first 5 days of enteral nutrition.

AIMS: It is unclear whether prescribing a higher amount of calories by enteral nutrition (EN) increases actual delivery. This prospective controlled study aimed at comparing the progression of EN of two study populations with different levels of calorie prescriptions, during the first 5 days of EN. METHODS: The daily calorie prescription of group 1 (n=346) was 25 and 20 kcal/kg body weight for women <60 and > or =60 years, respectively, and 30 and 25 kcal/kg body weight for men <60 and > or =60 years, respectively. The prescription of group 2 (n=148) was 5 kcal/kg body weight higher than in group 1. Calorie intakes were expressed as percentage of resting energy expenditure (REE) and protein intakes as percentage of requirements estimated as 1.2 g/kg body weight/day. Patients were classified as <60 and > or =60 years and as medical or surgical patients. Statistical analysis was performed with ANOVA for repeated measures. RESULTS: Calorie and protein deliveries increased in both groups independently of age and ward categories (P< or =0.0001). Group 2 showed faster progressions of calorie and protein intakes than group 1 in patients altogether (P< or =0.002), > or =60 years (P< or =0.01) and in surgical patients (P< or =0.02). Differences of calorie and protein intakes between day 1 and day 5 were significantly higher in group 2 than group 1 for patients altogether (75+/-61 vs. 56+/-54% of REE; 41+/-30 vs. 31+/-/-27% of protein requirements), those over 60 years (76+/-67 of REE vs. 52+/-59 of protein requirements) and surgical patients (81+/-52 vs. 58+/-57% of REE; 44+/-27 vs. 33+/-29% of protein requirements). CONCLUSIONS: Increasing the levels of EN prescriptions improved calorie and protein deliveries. While the mean energy delivery over 5 days was sufficient to cover requirements, the protein delivery by EN was insufficient, despite our nutritional support team.

Analysis of Variance↗

Expiratory trigger setting in pressure support ventilation: from mathematical model to bedside.

OBJECTIVE: To evaluate the feasibility of relying on a mathematical model to adjust the optimal level of expiratory trigger, materialized by the ratio of inspiratory flow at the end of inspiratory effort (V'ti) and peak inspiratory flow (V'peak), or V'ti/V'peak, during pressure support, by comparing its predicted values with those measured in intubated patients. DESIGN: Prospective observational study. SETTING: Medical intensive care unit, university hospital. PATIENTS: There were 28 intubated patients undergoing pressure support. INTERVENTIONS: Pressure support as set by the clinician in charge. MEASUREMENTS AND MAIN RESULTS: A significant correlation was found between predicted and measured V'ti/V'peak ratios (r =.70; p <.001; mean +/- sd difference, -0.025 +/- 0.07; 95% confidence interval, -0.161 to 0.111). Overall, delayed cycling occurred in obstructive conditions, the delay increasing as obstructive disease was more severe. CONCLUSIONS: A significant correlation was observed between predicted values of V'ti/V'peak and those values measured in patients undergoing pressure support. These findings should stimulate further research into the possible applications of this mathematical model to optimize expiratory trigger setting. Furthermore, our findings suggest that expiratory trigger should be adjustable and provide a wider range of cutoff levels than that which is currently available.

Feasibility Studies↗

Comparative effects of helium-oxygen and external positive end-expiratory pressure on respiratory mechanics, gas exchange, and ventilation-perfusion relationships in mechanically ventilated patients with chronic obstructive pulmonary disease.

OBJECTIVE: To compare the effects of He/O(2) and external PEEP (PEEPe) on intrinsic PEEP (PEEPi), respiratory mechanics, gas exchange, and ventilation/perfusion (V(A)/Q) in mechanically ventilated COPD patients. DESIGN AND SETTING: Prospective, interventional study in the intensive care unit of a university hospital. INTERVENTIONS: Ten intubated, sedated, paralyzed, mechanically ventilated COPD patients studied in the following conditions: (a) baseline settings made by clinician in charge, air/O(2), ZEEP; (b) He/O(2), ZEEP; (c) air/O(2), ZEEP; (d) air/O(2), PEEPe 80% of PEEPi. Measurements at each condition included V(A)/Q by the multiple inert gas elimination technique (MIGET). RESULTS: PEEPi and trapped gas volume were comparably reduced by He/O(2) (4.2+/-4 vs. 7.7+/-4 cmH(2)O and 98+/-82 vs. 217+/-124 ml, respectively) and PEEPe (4.4+/-1.3 vs. 7.8+/-3.6 cmH(2)O and 120+/-107 vs. 216+/-115 ml, respectively). He/O(2) reduced inspiratory and expiratory respiratory system resistance (15.5+/-4.4 vs. 20.7+/-6.9 and 19+/-9 vs. 28.8+/-15 cmH(2)O l(-1)s(-1), respectively) and plateau pressure (13+/-4 vs. 17+/-6 cmH(2)O). PEEPe increased airway pressures, including total PEEP, and elastance. PaO(2)/FIO(2) was slightly reduced by He/O(2) (225+/-83 vs. 245+/-82) without significant V(A)/Q change. CONCLUSIONS: He/O(2) and PEEPe comparably reduced PEEPi and trapped gas volume. However, He/O(2) decreased airway resistance and intrathoracic pressures, at a small cost in arterial oxygenation. He/O(2) could offer an attractive option in COPD patients with PEEPi/dynamic hyperinflation.

Aged↗

Effects of helium-oxygen on respiratory mechanics, gas exchange, and ventilation-perfusion relationships in a porcine model of stable methacholine-induced bronchospasm.

OBJECTIVE: To explore the consequences of helium/oxygen (He/O(2)) inhalation on respiratory mechanics, gas exchange, and ventilation-perfusion (VA/Q) relationships in an animal model of severe induced bronchospasm during mechanical ventilation. DESIGN: Prospective, interventional study. SETTING: Experimental animal laboratory, university hospital. INTERVENTIONS: Seven piglets were anesthetized, paralyzed, and mechanically ventilated, with all ventilator settings remaining constant throughout the protocol. Acute stable bronchospasm was obtained through continuous aerosolization of methacholine. Once steady-state was achieved, the animals successively breathed air/O(2) and He/O(2) (FIO(2) 0.3), or inversely, in random order. Measurements were taken at baseline, during bronchospasm, and after 30 min of He/O(2) inhalation. RESULTS: Bronchospasm increased lung peak inspiratory pressure (49+/-6.9 vs 18+/-1 cm H(2)O, P<0.001), lung resistance (22.7+/-1.5 vs 6.8+/-1.5 cm H(2)O x l(-1).s, P<0.001), dynamic elastance (76+/-11.2 vs 22.8+/-4.1 cm H(2)O x l(-1), P<0.001), and work of breathing (1.51+/-0.26 vs 0.47+/-0.08, P<0.001). Arterial pH decreased (7.47+/-0.06 vs 7.32+/-0.06, P<0.001), PaCO(2) increased, and PaO(2) decreased. Multiple inert gas elimination showed an absence of shunt, substantial increases in perfusion to low VA/Q regions, and dispersion of VA/Q distribution. He/O(2) reduced lung resistance and work of breathing, and worsened hypercapnia and respiratory acidosis. CONCLUSIONS: In this model, while He/O(2) improved respiratory mechanics and reduced work of breathing, hypercapnia and respiratory acidosis increased. Close attention should be paid to monitoring arterial blood gases when He/O(2) is used in mechanically ventilated acute severe asthma.

Acute Disease↗

Respiratory muscle workload in intubated, spontaneously breathing patients without COPD: pressure support vs proportional assist ventilation.

OBJECTIVE: To compare the respiratory muscle workload associated with pressure support ventilation (PSV) and proportional assist ventilation (PAV) in intubated and spontaneously breathing patients without COPD. DESIGN AND SETTING: Prospective study, intensive care unit university hospital. INTERVENTIONS: Twenty intubated patients, during early weaning, PSV settings made by clinician in charge of the patient, and two levels of PAV, set to counterbalance 80% (PAV 80) and 50% (PAV 50) of both elastic and resistive loads, respectively. The patients were ventilated in the following order: 1) PSV; 2) PAV 50 or PAV 80; 3) PSV; 4) PAV 80 or PAV 50; 5) PSV. PSV settings were kept constant. MEASUREMENTS: Arterial blood gases, breathing pattern and respiratory effort parameters at the end of each of the five steps. MAIN RESULTS: PSV and PAV 80 had the same effects on work of breathing (WOB). The pressure-time product (PTP) was significantly higher during PAV 80 than during PSV (90+/-76 and 61+/-56 cmH(2)O.s.min(-1), respectively, P <0.05). Tidal volume was comparable, albeit more variable with PAV 80 than with PSV (variation coefficient, 43% vs 25%, respectively, P <0.05). PAV 50 entailed a higher respiratory rate, lower tidal volume, and higher WOB and PTP than PSV and PAV 80. PaO(2)/FiO(2) and SaO(2) were lower with PAV 50 than with PSV and PAV 80. CONCLUSION: In a group of intubated spontaneously breathing non-COPD patients, PAV 80 and PSV were associated with comparable levels WOB, whereas PTP was higher during PAV 80. PAV 50 provided insufficient respiratory assistance.

Adult↗

Usefulness of helium-oxygen mixtures in the treatment of mechanically ventilated patients.

The density of helium is markedly lower than that of air or any of its components, leading to a substantial decrease in airway resistance to flow when it is inhaled. In mechanically ventilated patients with obstructive airway disease, replacing the usual air-oxygen mixture with helium-oxygen has been shown to reduce dynamic hyperinflation and intrinsic positive end-expiratory pressure; to decrease lung inflation pressures, respiratory acidosis, and work of breathing; and to improve arterial blood gases. Aerosol delivery to distal airways is enhanced with helium-oxygen. Preliminary data also suggest that the use of helium-oxygen could be a valuable approach to decrease postextubation respiratory distress. However, interference with ventilator function and added costs are two major disadvantages of helium-oxygen. Hence, before its widespread use in mechanically ventilated patients can be recommended, studies are needed to determine whether these favorable short-term effects can influence patient outcome.

Helium↗

Helium-oxygen versus air-oxygen noninvasive pressure support in decompensated chronic obstructive disease: A prospective, multicenter study.

OBJECTIVE: To study whether noninvasive pressure support ventilation (NIPSV) with helium/oxygen (He/oxygen), which can reduce dyspnea, PaCO2, and work of breathing more than NIPSV with air/oxygen in decompensated chronic obstructive pulmonary disease, could have beneficial consequences on outcome and hospitalization costs. DESIGN: Prospective, randomized, multicenter study. SETTING: Intensive care units of three tertiary care university hospitals. PATIENTS: All patients with chronic obstructive pulmonary disease admitted to the intensive care units for NIPSV during a 24-month period. INTERVENTIONS: Patients were randomized to NIPSV with air/oxygen or He/oxygen. NIPSV settings, number of daily trials, decision to intubate, and intensive care unit and hospital discharge criteria followed standard practice guidelines. RESULTS: A total of 123 patients (male/female ratio, 71:52; age, 71 +/- 10 yrs, Acute Physiology and Chronic Health Evaluation II, 17 +/- 4) were included. Intubation rate (air/oxygen 20% vs. He/oxygen 13%) and length of stay in the intensive care unit (air/oxygen 6.2 +/- 5.6 vs. He/oxygen 5.1 +/- 4 days) were comparable. The post-intensive care unit hospital stay was lower with He/oxygen (air/oxygen 19 +/- 12 vs. He/oxygen 13 +/- 6 days, p < .002). Cost of NIPSV gases was higher with He/oxygen, but total hospitalization costs were lower by $3,348 per patient with He/oxygen. No complications were associated with the use of He/oxygen. CONCLUSION: He/oxygen did not significantly reduce intubation rate or intensive care unit stay, but hospital stay was shorter and total costs were lower. He/oxygen NIPSV can be safely administered and could prove to be a cost-effective strategy.

APACHE↗