Whole-genome sequencing implicates rare, low-frequency and structural non-coding variation at the SCN5A locus in Brugada syndrome.

Brugada syndrome (BrS) is an inherited cardiac condition characterized by a hallmark ECG pattern and an increased risk of sudden cardiac death. Central to the aetiology of BrS, the SCN5A region harbours both common non-coding risk variants and rare coding variants that are causative in approximately 20% of patients. However, rare non-coding genetic variation in this region remains largely unexplored. Here, we used whole-genome sequencing (WGS) of 752 European-ancestry BrS cases and 1,827 ancestry-matched controls to identify BrS-associated rare non-coding genetic variation at the SCN5A locus. Sliding-window and cis-regulatory element (CRE)-based rare-variant aggregate testing implicated three conserved CREs, including a dense aggregation of case singleton variants within a 178 bp enhancer in intron 17 of SCN5A which replicated in an independent BrS cohort. Prioritised BrS-associated rare and low-frequency non-coding variants within these elements were predicted to alter cardiac transcription factor motifs, and altered CRE activity in hiPSC-CM luciferase assays or were associated with BrS-relevant ECG endophenotypes in the UK Biobank. Single-variant analysis across the region identified a Bonferroni-significant five-fold case-enriched low-frequency variant within a known CRE in intron 1 of SCN5A, which replicated, was associated with slower cardiac conduction in the UK Biobank and accounted for part of the BrS GWAS signal at this locus. Structural variant analyses identified a 10.5 kb deletion upstream of SCN5A in a BrS case that encompassed a cardiac CRE and reduced sodium current density in a hiPSC-CM model, as well as a 6 kb BrS-enriched retrotransposon insertion in SCN5A that appeared to underlie part of the GWAS signal in this region. Together, these findings implicate rare and low-frequency non-coding variation at the SCN5A locus in BrS susceptibility and demonstrate the value of targeted WGS analysis of key disease loci.

Journal Article↗

Outcome after implantation of a cardioverter-defibrillator in patients with Brugada syndrome: a multicenter study.

BACKGROUND: Brugada syndrome is an arrhythmogenic disease characterized by an increased risk of sudden cardiac death (SCD) by ventricular fibrillation. At present, an implantable cardioverter-defibrillator (ICD) is the recommended therapy in high-risk patients. This multicenter study reports the outcome of a large series of patients implanted with an ICD for Brugada syndrome. METHODS AND RESULTS: All patients (n=220, 46+/-12 years, 183 male) with a type 1 Brugada ECG pattern implanted with an ICD in 14 centers between 1993 and 2005 were investigated. ICD indication was based on resuscitated SCD (18 patients, 8%), syncope (88 patients, 40%), or positive electrophysiological study in asymptomatic patients (99 patients, 45%). The remaining 15 patients received an ICD because of a family history of SCD or nonsustained ventricular arrhythmia. During a mean follow-up of 38+/-27 months, no patient died and 18 patients (8%) had appropriate device therapy (10+/-15 shocks/patient, 26+/-33 months after implantation). The complication rate was 28%, including inappropriate shocks, which occurred in 45 patients (20%, 4+/-3 shocks/patient, 21+/-20 months after implantation). The reasons for inappropriate therapy were lead failure (19 patients), T-wave oversensing (10 patients), sinus tachycardia (10 patients), and supraventricular tachycardia (9 patients). Among implantation parameters, high defibrillation threshold, high pacing threshold, and low R-wave amplitude occurred, respectively, in 12%, 27%, and 15% of cases. CONCLUSIONS: In this large Brugada syndrome population, a low incidence of arrhythmic events was found, with an annual event rate of 2.6% during a follow-up of >3 years, in addition to a significant risk of device-related complications (8.9%/year). Inappropriate shocks were 2.5 times more frequent than appropriate ones.

Adult↗

Echocardiographic right ventricular strain analysis in chronic heart failure.

OBJECTIVE: We sought to compare the additive value of right ventricular (RV) function assessed by longitudinal systolic strain (epsilon% - ROI: 9.2 at 10.8 mm) with cardiopulmonary exercise testing (CPET) or brain natriuretic peptide (BNP) in patients with heart failure (HF). METHOD: We studied 19-patients (age = 56 +/- 8 years) in New York Heart Association HF class III-IV, who underwent standard and tissue Doppler echocardiography, CPET and BNP measurements on the same day. RV function was assessed by systolic strain (epsilon, %, ROI: 9.2-10.8 mm) in the mid-segment. Clinical outcomes were examined at 6 months. RESULTS: epsilon (-19.9+/-6.8%) was correlated with BNP (R = 0.52, P = 0.02), slope VE/VCO(2) (R = -0.65, P = 0.003), peak VO(2) (R = 0.46, P = 0.04) and the maximal workload (Watts) developed during CPET (R = 0.54, P=0.02). During follow-up, 1-patient died, 1-underwent heart transplantation, and 4 were re-hospitalized for worsening HF. Patients with major adverse cardiac events (MACE) had a significantly higher mean BNP concentration (852.8 ng/mL +/- 1114.3 vs. 201.4+ /- 293.8, P = 0.03), higher VE/VCO(2) (41.3 +/- 3.6 vs. 35.0 +/- 4.8 P < 0.001) and lower epsilon (-13.9 +/- 4.9 vs. -22.2+ /- 5.8, P < 0.001) than patients who remained MACE-free. By multivariate analysis, ST was the only predictor of MACE. CONCLUSION: In HF-patients presenting, RV-function assessed by systolic epsilon was reliable, easily measurable and a stronger prognosticator than CPET or BNP.

Chronic Disease↗

Use of a new cardiac pacing mode designed to eliminate unnecessary ventricular pacing.

AIMS: To examine the performance of AAIsafeR2, a new pacing mode to minimize the cumulative proportion of ventricular pacing in patients who do not need regular ventricular support. METHODS AND RESULTS: The safety of AAIsafeR2 was examined in 123 recipients (73 +/- 12 years old, 51% men) of dual chamber pacemakers implanted for sinus node dysfunction, paroxysmal AV block or the bradycardia-tachycardia syndrome. Data were collected from pacemaker diagnostics, and the first 43 patients underwent 24-h Holter recordings before being discharged from the hospital with AAIsafeR2 activated. No adverse event related to AAIsafeR2 was observed. All ventricular pauses detected on Holter tapes triggered immediate back-up ventricular pacing. Appropriate switches to DDD occurred in 97 of 123 patients. In 69 of 123 devices (56%) switches to DDD were non-sustained, and the average % ventricular pacing in this group was 0.2+/-0.5%. CONCLUSION: AAIsafeR2 mode seems to be safe and reliable in patients with infrequent slowing or pauses in ventricular activity, while maintaining ventricular pacing below 1%.

Aged↗

Cardiac resynchronisation therapy in heart failure: current status.

Cardiac resynchronization in heart failure already has a history of 12 years. However, the major advances have been the result of large multi center trials dating from 2001. In all these trials patients with a LVEF < or = 35% were included, and a QRS above 120 msec. Follow up was from 3-36 months. The majority of these trials showed a positive effect in reduction of composite and points of death or hospitalization for major cardiovascular events. Many of these trials also showed a diminution of left ventricular and systolic diameter or volume. Even in NYHA class II patients an improvement was seen. Some unanswered questions still remain as regards the agreement on electrical or electromechanical dyssynchrony criteria. There is a number of patients with "wide" QRS who do not improve and conversely a number of patients with a narrow QRS who witness improvement. The benefit in patients with atrial fibrillation also remains unanswered. Finally the value of this modality in patients with mild heart failure or asymptomatic left ventricular systolic dysfunction, NYHA class I-II remains to be determined in large on going trials. Another question is whether biventricular or left ventricular patient is preferable. Finally whether biventricular patient should be complemented by a defibrillator insertion is being currently studied. Cardiac resynchronization therapy along or in combination with an ICD improves symptoms, reduces major morbidity and mortality in patients with a left ventricular EF<35%, ventricular dilatation and a QRS > or = 120 msec in NYHA class III-IV. Further indications are currently being examined.

Cardiac Pacing, Artificial↗

A randomized comparison of permanent septal versus apical right ventricular pacing: short-term results.

OBJECTIVES: This study compared chronic right ventricular (RV) pacing at the septum versus apex. BACKGROUND: Chronic RV apical pacing may be detrimental to ventricular function. This randomized, pilot study examined whether, compared with apical, permanent septal pacing preserves cardiac function. METHODS: Ablation of the atrioventricular junction for permanent AF, followed by implantation of a DDDR pacemaker connected to two ventricular leads was performed in 28 patients. One lead screwed into the septum and another placed at the apex were connected to the atrial and ventricular port, respectively. Septum or apex was paced by programming AAIR or VVIR modes, respectively. Patients were randomly assigned, 4 months later, to pacing at one site for 3 months, and crossed over to the other for 3 months. New York Heart Association class, QRS width and axis, left ventricular ejection fraction (LVEF), exercise duration, and peak oxygen uptake were measured. Results in patients with LVEF > 45% and < or = 45% were compared. RESULTS: Septal pacing was associated with shorter QRS (145 +/- 4 msec vs 170 +/- 4 msec, P < 0.01) and normal axis (40 degrees +/- 10 degrees vs -71 +/- 4 degrees , P < 0.01). At 3 months, among patients with baseline LVEF < or = 45%, LVEF was 42 +/- 5% after septal pacing versus 37 +/- 4% after apical pacing (P < 0.001). CONCLUSION: In contrast to RV apical pacing, chronic RV septal pacing preserved LVEF in patients with baseline LVEF < or = 45%.

Atrial Fibrillation↗

Right ventricular versus biventricular antitachycardia pacing in the termination of ventricular tachyarrhythmia in patients receiving cardiac resynchronization therapy: the ADVANCE CRT-D trial.

BACKGROUND: The purpose of this investigation is to compare the efficacy of antitachycardia pacing (ATP) delivered via the right ventricular (RV) lead versus ATP delivered simultaneously via the right and left ventricular leads (biventricular [BiV]) in the termination of ventricular tachyarrhythmia (VT) in patients receiving cardiac resynchronization therapy (CRT) with ICD capabilities. METHODS AND RESULTS: The ADVANCE CRT is a prospective, multicenter, randomized, parallel trial evaluating RV versus BiV ATP in the termination of VT in CRT patients. The study will test the hypothesis that BiV ATP is superior to RV ATP in the termination of VT and fast VT. All patients with class I and IIa indications for an ICD implantation and CRT are included. The sample size has been estimated to 400 participants followed for 12 months to show a 10% benefit of BiV versus RV ATP. The efficacy of BiV ATP to terminate all VT presents the primary endpoint. The investigation is expected to be completed in 2007. CONCLUSIONS: The ADVANCE CRT trial is the first large randomized clinical investigation evaluating the efficacy of BiV ATP in patients under CRT and ICD therapy.

Adolescent↗

There is plenty of room for cardiac resynchronization therapy devices without back-up defibrillators in the electrical treatment of heart failure.

Patients with chronic heart failure might benefit from electrical therapy with a view to resynchronize the heart and improve its mechanical performance by cardiac resynchronization therapy (CRT) or to prevent the risk of sudden death by automatic defibrillation. These two therapies can be applied separately or with a combined device, the biventricular implantable cardioverter-defibrillator (CRT-D). There is currently no strong scientific evidence indicating that a CRT-D must be offered to all candidates for CRT. Plain common sense should limit the prescription of these costly devices for patients in need of secondary prevention or for younger patients without major comorbidities. The preferential choice of CRT pacemakers in the remainder of patients is currently a logical one.

Cardiac Output, Low↗

Clinical and electrocardiographic predictors of a positive response to cardiac resynchronization therapy in advanced heart failure.

AIMS: Cardiac resynchronization therapy (CRT) is an effective treatment for refractory congestive heart failure (CHF). However, up to 30% of patients do not respond to CRT. The aim of this study was to identify clinical and electrocardiographic (ECG) predictors of a positive response to CRT. METHODS AND RESULTS: This retrospective study included 139 consecutive patients successfully implanted with a CRT device (mean age, 68+/-9 years, 113 men). At baseline, 69% of patients were in New York Heart Association (NYHA) functional class III, and 31% in class IV, mean left ventricular ejection fraction was 21+/-6%, and mean QRS duration was 188+/-28 ms. In each patient, left and right ventricular leads were placed to attain the shortest QRS duration during biventricular stimulation. Patients were classified at 6 months as responders to CRT (n=100) if they were alive, they had not been re-hospitalized for management of CHF, and the NYHA class had decreased by 1 point, and/or peak VO(2) or 6 min hall-walk increased by >10%. All others were classified as non-responders (n=38; one patient was lost to follow-up). Uni- and multivariate logistic regression analyses were performed to detect a pre- or intra-operative predictor of a positive response to CRT. Among multiple demographic, clinical, and ECG variables, the amount of QRS shortening (DeltaQRS) associated with biventricular stimulation was the only independent predictor of a positive (37+/-23 ms) vs. negative (11+/-23 ms) response to CRT (P<0.001). CONCLUSION: A positive response to CRT was observed in 73% of patients at 6 months and predicted only by DeltaQRS.

Aged↗

A new dual-chamber pacing mode to minimize ventricular pacing.

Despite the low long-term incidence of high-degree atrioventricular (AV) block and the known negative effects of ventricular pacing, programming of the AAI mode in patients with sinus node dysfunction (SND) remains exceptional. A new pacing mode was, therefore, designed to combine the advantages of AAI with the safety of DDD pacing. AAIsafeR behaves like the AAI mode in absence of AV block. First- and second-degree AV blocks are tolerated up to a predetermined, programmable limit, and conversion to DDD takes place in case of high-degree AV block. From DDD, the device may switch back to AAI, provided AV conduction has returned. The safety of AAIsafeR was examined in 43 recipients (70 +/- 12-year old, 24 men) of dual chamber pacemakers implanted for SND or paroxysmal AV block. All patients underwent 24-hour ambulatory electrocardiographic recordings before hospital discharge and at 1 month of follow-up with the AAIsafeR mode activated. No AAIsafeR-related adverse event was observed. At 1 month, the device was functioning in AAIsafeR in 28 patients (65%), and the mean rate of ventricular pacing was 0.2%+/- 0.4%. Appropriate switches to DDD occurred in 15 patients (35%) for frequent, unexpected AV block. AAIsafeR mode was safe and preserved ventricular function during paroxysmal AV block, while maintaining a very low rate of ventricular pacing. The performance of this new pacing mode in the prevention of atrial fibrillation will be examined in a large, controlled study.

Aged↗

Automatic recognition of abnormal respiratory events during sleep by a pacemaker transthoracic impedance sensor.

INTRODUCTION: A number of pacemakers use transthoracic impedance to derive minute ventilation as a sensor for rate adaptation. Transthoracic impedance is also able to track fluctuations in tidal volume occurring in sleep apnea/hypopnea syndromes (SAS). We evaluated the feasibility of a transthoracic impedance-derived pacemaker algorithm for monitoring sleep respiratory disturbances. METHODS AND RESULTS: Forty-two patients who presented with a conventional indication for DDD pacing or cardiac resynchronization underwent conventional polysomnography 1 month after implantation of a Talent trade mark 3 pacemaker (ELA Medical). The respiratory disturbance index (RDI) stored in the pacemaker memory was compared to the apnea/hypopnea index (AHI) derived from polysomnography. The ability of the pacemaker to identify severe SAS patients (AHI > or = 30) was assessed. A minimal systematic error was observed from a Bland and Altman plot (bias = 0.9 events/hour). The ability of the pacemaker RDI to identify severe SAS patients was determined by analysis of the receiver operator characteristic. A cutoff RDI value of 30.6/hour of recording was found to yield 75% sensitivity, 94% specificity, 75% positive predictive value, and 94% negative predictive value. CONCLUSION: The RDI monitoring function appears to be of value in screening pacemaker patients for SAS. Its performance is comparable to existing simple screening techniques. The ability to permanently monitor respiration, in combination with other diagnostic capabilities (such as Holter functions), presents a unique opportunity to monitor the association between arrhythmias and disturbances of breathing during sleep.

Aged↗

Intra- and interatrial conduction delay: implications for cardiac pacing.

Atrial conduction disorders are frequent in elderly subjects and/or those with structural heart diseases, mainly mitral valve disease, hyperthrophic cardiomyopathies, and hypertension. The resultant electrophysiological and electromechanical abnormalities are associated with a higher risk of paroxysmal or persistent atrial tachyarrhythmias, either atrial fibrillation, typical or atypical flutter or other forms of atrial tachycardias. Such an association is not fortuitous because intra- and interatrial conduction abnormalities delays disrupt (spatial and temporal dispersion) electrical activation, thus promoting the initiation and perpetuation of reentrant circuits. Preventive therapeutic interventions induce variable, sometimes paradoxical effects as with the proarrhythmic effect of class I antiarrhythmic drugs. Similarly, atrial pacing may promote proarrhythmias or an antiarrhythmic effect according to the pacing site(s) and mode. Multisite atrial pacing was conceived to correct, as much as possible, abnormal activation induced by spontaneous intra- or interatrial conduction disorders or by single site atrial pacing, which are situations responsible for commonly refractory arrhythmias. Atrial electrical resynchronization can also be used to correct mechanical abnormalities like left heart AV dyssynchrony resulting from intraatrial conduction delays.

Atrial Fibrillation↗

Predicting survival causes after out of hospital cardiac arrest using data mining method.

BACKGROUND: The prognosis of life for patients with heart failure remains poor. By using data mining methods, the purpose of this study was to evaluate the most important criteria for predicting patient survival and to profile patients to estimate their survival chances together with the most appropriate technique for health care. METHODS: Five hundred and thirty three patients who had suffered from cardiac arrest were included in the analysis. We performed classical statistical analysis and data mining analysis using mainly Bayesian networks. RESULTS: The mean age of the 533 patients was 63 (+/- 17) and the sample was composed of 390 (73 %) men and 143 (27 %) women. Cardiac arrest was observed at home for 411 (77 %) patients, in a public place for 62 (12 %) patients and on a public highway for 60 (11 %) patients. The belief network of the variables showed that the probability of remaining alive after heart failure is directly associated to five variables: age, sex, the initial cardiac rhythm, the origin of the heart failure and specialized resuscitation techniques employed. CONCLUSIONS: Data mining methods could help clinicians to predict the survival of patients and then adapt their practices accordingly. This work could be carried out for each medical procedure or medical problem and it would become possible to build a decision tree rapidly with the data of a service or a physician. The comparison between classic analysis and data mining analysis showed us the contribution of the data mining method for sorting variables and quickly conclude on the importance or the impact of the data and variables on the criterion of the study. The main limit of the method is knowledge acquisition and the necessity to gather sufficient data to produce a relevant model.

Bayes Theorem↗

Suspected pacemaker or defibrillator transvenous lead infection. Prospective assessment of a TEE-guided therapeutic strategy.

AIMS: The aim of this prospective study was to assess the clinical value of a management strategy principally based on the results of multiplane transoesophageal echocardiography (TEE) in patients with suspected lead infection. METHODS AND RESULTS: Seventy-seven consecutive patients were included. Based on Duke's modified criteria, PTLI was considered as definite in 54 patients (70%) and possible in 23 patients (30%). Nineteen patients with a diagnosis of possible infection, as defined by bacteraemia without abnormal TEE images and without evidence of pacemaker pocket infection, were treated by antibiotics alone. In all other cases, the pacing material was totally removed. During a mean follow-up time of 3.1+/-2.5 years, 21 patients (27%) died, mostly from cardiovascular causes. Only one patient died from infection and there was only one case of delayed infection recurrence in an other localization. No significant differences in outcome were observed between explanted and non-explanted patients. CONCLUSIONS: The results observed confirm that early and total explantation of pacing material has to be done in patients with bacteraemia and abnormal images at TEE. But conversely conservation of the pacing system can be proposed to patients with bacteraemia but without abnormal images at TEE provided prolonged antibiotic treatment is given.

Adult↗

Long-term experience with a preshaped left ventricular pacing lead.

This study describes a long-term experience with a new LV pacing lead. The study population consisted of 62 patients (85% men, 71 +/- 10 years old) with advanced dilated cardiomyopathy, in NYHA Class III or IV despite optimal drug therapy, and a QRS duration > 150 ms. Patients in sinus rhythm were implanted with a triple chamber pacemaker to maintain atrioventricular synchrony. A dual chamber pacemaker was implanted in patients in atrial fibrillation for biventricular pacing only. A clinical evaluation and interrogation of the resynchronization pacemaker were performed at implant, at 1 week (W1), one (M1), four (M4), and seven (M7) months after implantation. A longer follow-up (2 years) is available for patients implanted at the authors institution. LV measurements were pacing threshold at 0.5-ms pulse duration and pacing impedance. R wave amplitude (mV) was measured at the time of implantation only. The system was successfully implanted in 86% of patients with the latest design of the lead. Mean R wave amplitude at implant was 15 +/- 7 mV and mean pacing impedance was 1054 +/- 254 omega. Between implant (n = 38) and M7 (n = 15), pacing threshold rose from 0.73 +/- 0.54 to 1.57 +/- 0.60 V (P < 0.001). In conclusion, the situs lead was successfully implanted in a high percentage of patients. In addition, low pacing threshold and high impedance measured during follow-up are consistent with a low pacing current drain, ensuring a durable pulse generator longevity.

Aged↗

Study of precursors of ventricular tachycardia from data stored in the memory of a dual chamber implantable cardioverter defibrillator.

This study was performed to examine precursors of ventricular tachyarrhythmias in patients who experienced a sustained ventricular tachyarrhythmia and received appropriate therapy by ICD. From an overall consecutive population of 77 patients, 18 patients (1 woman, mean age 61.7 +/- 10.8 years) were selected for having experienced a sustained ventricular tachyarrhythmia and received at least one appropriate ICD therapy preceded by 20 minutes of internal information. The number of premature ventricular complexes (PVCs)/min for each of the 20 minutes preceding the onset of ventricular tachyarrhythmia, the shortest coupling intervals between PVC and normal sinus beat, and the presence of short-long-short (SLS) interval sequences were examined. Data were stratified according to underlying disease, left ventricular ejection fraction, rate of ventricular tachyarrhythmia, and antiarrhythmic therapy. One hundred twenty-eight episodes of spontaneous ventricular tachyarrhythmia were retrieved. Rapid ventricular tachyarrhythmia (>160 beats/min) were preceded by a significantly greater mean number (3.71 +/- 6.36)of PVCs than slower ventricular tachyarrhythmia (<or=160 beats/min) (0.63 +/- 0.88, P = 0.0004). The mean shortest PVC coupling interval was significantly shorter in patients with (588 +/- 99 ms) versus without (643 +/- 111 ms, P = 0.03)ischemic heart disease, before episodes of rapid(527 +/- 55 ms)versus slower (636 +/- 105 ms, P = 0.0001)ventricular tachyarrhythmia, and in the absence (538 +/- 80 ms)versus the presence(620 +/- 105 ms, P = 0.006)of amiodarone. SLS sequences preceded 29% of rapid ventricular tachyarrhythmic episodes, versus 8% of the slower ventricular tachyarrhythmia (P < 0.01). Significant differences were found in the characteristics of PVCs preceding ventricular tachyarrhythmic episodes in accordance to their rate and the underlying cardiomyopathy. Though insufficient in isolation, these findings may be helpful when combined with other observations to develop preventive algorithms, or to refine the programming of implantable devices.

Amiodarone↗

Novel brugada SCN5A mutation leading to ST segment elevation in the inferior or the right precordial leads.

Mutations in the SCN5A gene can lead to the Brugada syndrome, a genetically inherited form of idiopathic ventricular fibrillation that has a characteristic ECG phenotype usually restricted to precordial leads V1-V3. We identified a novel G752R SCN5A missense mutation leading to various degrees of the Brugada ECG phenotype in members of a French family. In the proband, the G752R mutation produced ST segment elevation and prominent J wave in leads II, III, and aVF. In four other relatives, ST segment elevation in the right precordial but not in the inferior leads was observed either spontaneously or under flecainide challenge. Recombinant G752R mutant exhibited a markedly reduced Na+ current amplitude and a voltage shift in both activation and inactivation curves. The mutant was found in all affected but not in nonaffected family members. One additional gene-carrier had an almost normal ECG (silent gene-carrier). We provide genetic demonstration that Brugada ECG anomalies related to a unique SCN5A mutation can be observed either in the inferior or the right precordial leads.

Adult↗