PubMed Health⌕ Search

Biomedical subjects

Pietro Regazzoni

Publications and source records attributed to Pietro Regazzoni.

10 recordsLinked to original sources

A CT database for research, development and education: concept and potential.

Both in radiology and in surgery, numerous applications are emerging that enable 3D visualization of data from various imaging modalities. In clinical practice, the patient's images are analyzed on work stations in the Radiology Department. For specific preclinical and educational applications, however, data from single patients are insufficient. Instead, similar scans from a number of individuals within a collective must be compiled. The definition of standardized acquisition procedures and archiving formats are prerequisite for subsequent analysis of multiple data sets. Focusing on bone morphology, we describe our concept of a computer database of 3D human bone models obtained from computed tomography (CT) scans. We further discuss and illustrate deployment areas ranging from prosthesis design, over virtual operation simulation up to 3D anatomy atlases. The database of 3D bone models described in this work, created and maintained by the AO Development Institute, may be accessible to research institutes on request.

Bone and Bones↗

Unexpected high complication rate following internal fixation of unstable proximal humerus fractures with an angled blade plate.

OBJECTIVES: The increasing number of fractures of the proximal humerus, especially in the elderly, carries with it the unsolved problem of the optimal treatment for the displaced or unstable fractures. The authors' goal was to analyze whether fixation with a bent valgus angled blade plate could improve the outcomes reported in the literature to date. DESIGN: Prospective clinical study. SETTING: Urban level 1 university trauma center. PATIENTS: Over a 27-month period, 42 consecutive patients were treated for an unstable or displaced proximal humerus fracture. INTERVENTION: Open reduction and internal fixation with a 90-degree cannulated angled blade plate prebent to 110 degrees. MAIN OUTCOME MEASUREMENTS: Active follow-up for 1 year with assessment of objective and subjective functional results (ie, motion; strength; Constant score; Disabilities of the Arm, Shoulder, and Hand (DASH) score; and visual analog scale (VAS)) and radiographic assessment (reduction, alignment, necrosis, and nonunion). RESULTS: Follow-up was completed for 86% of the patients, who achieved a mean Constant score of 66 points (82% of the contralateral side) with a mean forward flexion of 125 degrees and an average strength of 72% of the contralateral side. Low disability (mean DASH score 22) and pain values (mean VAS 2) were demonstrated after this type of stabilization. The overall complication rate was 33% (12/36), with protrusion of the blade into the glenohumeral articulation as the most frequent problem (8/36, 22%). The negative impact of an adverse event on subjective and objective outcomes was only significant for forward flexion (P = 0.02). Neither clinical outcome nor complication rate was different when compared to patients with regard to fracture type (3 versus 4 parts) or age (younger or older than 70 years). CONCLUSIONS: Fixation of displaced proximal humeral fractures with an angled blade plate provided sufficient stability. Blade perforation into the humeral joint occurred in every fourth patient and was found to be the major reason for a high complication rate. In view of this major problem, the technique described here cannot be recommended, even though the absence of nonunions in our series seems to support the low invasiveness of this surgical approach.

Adult↗

Use of the less invasive stabilization system (LISS) in patients with distal femoral (AO33) fractures: a prospective multicenter study.

INTRODUCTION: The Less Invasive Stabilization System (LISS) is an internal fixator that can be inserted percutaneously by means of a minimally invasive surgical approach. This paper presents the use of this system exclusively in patients with AO33 distal femoral fractures, a group in which fracture management is often complicated by multiple trauma and soft-tissue damage. MATERIALS AND METHODS: A series of 62 patients (mean age 52 years) with 66 AO33A or C fractures received the LISS implant and were followed prospectively for 12 months. Assessments included the radiographic evaluation of implant placement and healing, measurement of valgus/varus and sagittal joint malalignment, and the assessment of weight-bearing capacity and range of motion. RESULTS: The mean duration of surgery was 85 min (range 40-135 min) for 33A fractures and 149 min (range 50-300 min) for 33C fractures. Postoperative radiographic assessments showed that the LISS implant was positioned correctly in 59 cases (89%). Assessment of valgus/varus alignment showed correct axial alignment in 49 cases (74%), a deviation of 5-10 degrees in 13 cases, and a 10-20 degrees deviation in 1 case. Correct sagittal alignment was observed in 56 cases (85%), 5-10 degrees malalignment in 5 cases, and 10-20 degrees in 2 cases. During the course of the 1-year follow-up, 8 patients (9 fractures) died; 2 other patients were not available for follow-up. Complete fracture healing was achieved in 85% of the followed-up patients. Forty-eight patients were capable of full weight-bearing. After fracture healing, maximum flexion of the injured limb was on average 80% of the range of the uninjured limb. An extension deficit of more than 5 degrees was measured in 3 cases. Of the 62 patients, 14 underwent further operations during the course of follow-up. Of these, 6 required bone grafting and 3 refixation of the implant due to implant loosening. Deep infections requiring several debridements occurred in 2 patients. No complications relating solely to the implant were observed. CONCLUSION: The LISS showed good overall results in the treatment of these difficult fractures. It is a good alternative to conventional extramedullary and intramedullary stabilizing techniques, especially in more complex fracture situations.

Adult↗

Modality-based navigation.

Modality-based navigation (MBN) means the interactive tracking of instruments in a co-ordinate system defined by an imaging modality, eg, CT, MR, or a fluoroscope. During the registration process, a transformation matrix between the two co-ordinate systems of the digitizer and imaging modality is calculated. Navigation can start immediately after collection of the images without an intraprocedural registration process. Since the imaging modality belongs to the OR or the intervention suite, image update can be performed at any time. Following a step-by-step procedure with navigation and image update in a reasonable sequence, the risk for a virtual-real mismatch is minimized. For CT-MBN, we obtained a freehand absolute positioning accuracy of 1.9+/-1.1 mm in vitro. The in vivo freehand absolute positioning accuracy in pelvic fracture fixation was determined to be 3.1 mm (unpublished data). From our point of view, modality-based navigation is an efficient and safe alternative tool for computer aided interventions.

Fluoroscopy↗

The MEPUC concept adapts the C-arm fluoroscope to image-guided surgery.

Image-guided surgery requires surgeons to be able to manipulate the imaging modality themselves and without delay. Intraoperative fluoroscopic imaging does not meet this requirement as the C-arm fluoroscope cannot be operated or positioned by the surgeons themselves. The Motorized Exact Positioning Unit for C-arm (MEPUC) concept aims to optimize the workflow of positioning the C-arm fluoroscope. The hardware component of the MEPUC equips the fluoroscope with electric stepping motors. The software component allows the surgeon to control the fluoroscope's movements. The study presented here showed that translational movements within the x-y plane are most frequently performed when positioning the C-arm fluoroscope. Furthermore, reproducing a former projection was found to be a frequent task during image-guided procedures. In our opinion, the MEPUC concept adapts the fluoroscope to image-guided surgery. The most important improvement being definition of a bidirectional data exchange between the surgeon and the C-arm fluoroscope: positioning data from the surgeon to the C-arm fluoroscope and-subsequently-image information from C-arm fluoroscope to the surgeon.

Femoral Fractures↗

Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. A prospective, controlled clinical study.

A prospective controlled clinical study was performed to compare fluoroscopic guidance with fluoroscopy-based surgical navigation for distal locking of intramedullary implants. Forty-two patients with fractures of the lower extremity treated by intramedullary nailing were divided in two groups: distal locking either with fluoroscopic guidance (group I) or with surgical navigation (group II). The average fluoroscopic time to insert one interlocking screw with fluoroscopic guidance was 108 s compared with 7.3s in the navigation group. The average procedure time to insert one interlocking screw in group I was 13.7 min compared with 17.9 min in group II. The drill bit failed to pass through the interlocking hole in one patient from group II. There was no significant difference in the technical reliability between both groups. Fluoroscopic times to achieve equivalent precision are reduced with fluoroscopy-based surgical navigation compared with fluoroscopic guidance. Fluoroscopy-based surgical navigation is recommended for intraoperative guidance in situations where reduction of exposure to radiation is considered advantageous over the increase of procedure time.

Female↗

A faster method for 3D/2D medical image registration--a simulation study.

3D/2D patient-to-computed-tomography (CT) registration is a method to determine a transformation that maps two coordinate systems by comparing a projection image rendered from CT to a real projection image. Iterative variation of the CT's position between rendering steps finally leads to exact registration. Applications include exact patient positioning in radiation therapy, calibration of surgical robots, and pose estimation in computer-aided surgery. One of the problems associated with 3D/2D registration is the fact that finding a registration includes solving a minimization problem in six degrees of freedom (dof) in motion. This results in considerable time requirements since for each iteration step at least one volume rendering has to be computed. We show that by choosing an appropriate world coordinate system and by applying a 2D/2D registration method in each iteration step, the number of iterations can be grossly reduced from n6 to n5. Here, n is the number of discrete variations around a given coordinate. Depending on the configuration of the optimization algorithm, this reduces the total number of iterations necessary to at least 1/3 of it's original value. The method was implemented and extensively tested on simulated x-ray images of a tibia, a pelvis and a skull base. When using one projective image and a discrete full parameter space search for solving the optimization problem, average accuracy was found to be 1.0 +/- 0.6(degrees) and 4.1 +/- 1.9 (mm) for a registration in six parameters, and 1.0 +/- 0.7(degrees) and 4.2 +/- 1.6 (mm) when using the 5 + 1 dof method described in this paper. Time requirements were reduced by a factor 3.1. We conclude that this hardware-independent optimization of 3D/2D registration is a step towards increasing the acceptance of this promising method for a wide number of clinical applications.

Algorithms↗