PubMed Health⌕ Search

PubMed · 15183700

Modality-based navigation.

Abstract

Modality-based navigation (MBN) means the interactive tracking of instruments in a co-ordinate system defined by an imaging modality, eg, CT, MR, or a fluoroscope. During the registration process, a transformation matrix between the two co-ordinate systems of the digitizer and imaging modality is calculated. Navigation can start immediately after collection of the images without an intraprocedural registration process. Since the imaging modality belongs to the OR or the intervention suite, image update can be performed at any time. Following a step-by-step procedure with navigation and image update in a reasonable sequence, the risk for a virtual-real mismatch is minimized. For CT-MBN, we obtained a freehand absolute positioning accuracy of 1.9+/-1.1 mm in vitro. The in vivo freehand absolute positioning accuracy in pelvic fracture fixation was determined to be 3.1 mm (unpublished data). From our point of view, modality-based navigation is an efficient and safe alternative tool for computer aided interventions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Peter Messmer, Thomas Gross, Norbert Suhm, Pietro Regazzoni, Augustinus L Jacob, Rolf W Huegli. 2004. Modality-based navigation.. https://doi.org/10.1016/j.injury.2004.05.007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Pitfalls in the accurate measurement of joint space narrowing in semiflexed, anteroposterior radiographic imaging of the knee.

OBJECTIVE: Computerized measurement of changes in joint space width (JSW) on serial radiographs of the knee in the semiflexed, anteroposterior (SF-AP) view has been used recently as a primary outcome measure in clinical trials of disease-modifying osteoarthritis drugs (DMOADs). In the use of fluoroscopy to achieve reproducible alignment of the medial tibial plateau and x-ray beam, the SF-AP radiographic protocol affords greater sensitivity in the detection of joint space narrowing (JSN) than that achieved by conventional radiographic positioning techniques. However, the utility of the SF-AP view is compromised by the variation in x-ray penetration in each examination, which may confound the correction of the automated measurement of JSW for the radiographic magnification inherent in an AP view of the knee. A recent DMOAD trial using the SF-AP protocol showed an improbable increase in JSW of > or =0.50 mm (i.e., greater than the measurement error). The present report provides an analysis of this problem, and the study aim was to demonstrate that substitution of the automated estimates of JSW with precise manual measurements can markedly reduce the problem attributable to radiographic magnification. METHODS: SF-AP radiographs were obtained at baseline and at 16 months and 30 months thereafter from subjects enrolled in a 6-center DMOAD trial. For each examination, a 6.35-mm steel ball was affixed to the skin over the head of the fibula to permit estimation of the percentage of radiographic magnification (%Mag) and correction of JSW measurements. Measurements of the minimum interbone distance (IBD) in the medial tibiofemoral compartment and the %Mag were obtained by an automated method (edge detection) and manually. Combinations of automated and manual measurements of the IBD and %Mag in estimates of magnification-corrected JSW were compared with respect to their reproducibility, agreement, and sensitivity to JSN. RESULTS: With fully automated measurements, variations in x-ray penetration in analog radiographs and edge enhancement in digital radiographs resulted in the computer "seeing" a metal ball whose diameter was artifactually reduced, resulting in an inflated measurement of JSW. Use of manual measurement of the IBD and %Mag largely eliminated these problems and reduced, from 16% to 2%, the frequency of knees exhibiting an increase in JSW > or =0.50 mm. In 14 of the 15 knees in which a significant increase in JSW was noted with the manual method, this increase in JSW could be explained by the development of significant lateral compartment narrowing during the study or poor alignment of the medial plateau. CONCLUSION: Although automated and manual methods of JSW measurement of the knee in the SF-AP view possess comparable intrareader reproducibility, the manual method is less susceptible to technical factors that affect the correction of raw JSW estimates for radiographic magnification. Until we can identify practical, effective solutions to these technical problems, use of any radiographic protocol involving AP imaging of the knee in a DMOAD trial must be viewed with caution.

Fluoroscopy↗

Radiation risk management during fluoroscopy for interventional pain medicine physicians.

Because of serious radiographic-induced skin injuries that may have been caused by the inappropriate use of fluoroscopy during the performance of radiograph-guided invasive procedures, the US Food and Drug Administration (FDA) issued an advisory in 1994 suggesting that the key to preventing such unfortunate mishaps may be physician education, training, and credentialing in the safe operation of fluoroscopic equipment. The purpose of this article is to familiarize the interventional pain medicine physician with the physics of ionizing radiation and how to limit patient exposure through the optimum setting of tube current and voltage, the use of limited beam-on time, tight collimation, and the elimination of the nonessential use of the magnification mode on a fluoroscopy unit. In addition, the use of personal protection equipment and the knowledge needed to interpret the personal exposure record of each practitioner is discussed. All of this information will assist the interventional pain medicine physician in meeting the recommended FDA training and credentialing requirements.

Fluoroscopy↗