PubMed Health⌕ Search

Biomedical subjects

Qian-Hong Wan

Publications and source records attributed to Qian-Hong Wan.

4 recordsLinked to original sources

Packing structure and self-heating in capillary electrochromatography.

The origin of bubble formation during operation of capillary electrochromatography (CEC) has been an issue of debate. Ohmic heating resulted from current passed through a packed column was proposed as the primary cause. However, this explanation has been questioned on the ground that the current measured in CEC is much lower than that measured with open-tubular separation systems where no bubble formation occurs. To resolve this issue, we carried out a theoretical study correlating self-heating of the electrolyte with packing structure of the column. We used a bundle of capillary tubes, a bundle of two types of capillary tubes and two bundles of capillary tubes connected serially to model, respectively, the flow channels in the column of non-porous particles, in the column of porous particles and in the column of various packing densities. The results from this study indicate that, for columns of homogeneous packing density, the heat output is indeed smaller than that in open-tubular columns of the same dimensions. In this case, the self-heating cannot be a key factor responsible for the bubble formation in CEC. However, for columns of heterogeneous packing density, a large excess of heat release may be produced in column sections of high packing density and, in turn, over-heating in such sections may become the primary cause for the formation of bubbles. It follows from this study that preparation of columns of homogeneous packing structure is essential to obtain reproducible and bubble-free CEC systems.

Chromatography, Micellar Electrokinetic Capillary↗

Measurement of packing tortuosity and porosity in capillary electrochromatography.

The application of conductivity measurements for packing structure characterization has been extended to a column consisting of a packed section and an open section as typically used in capillary electrochromatography (CEC). Because of the difference in electric conductivity between the packed and open sections, the electric fields applied across the two sections vary, depending on the length of the packed section relative to that of the total column. On the basis of mass conservation law, it can be shown that the ratio of the electric current measured in such a duplex column to that without packing is a function of the length and the geometric structure of the packing bed. Thus, knowing the lengths of the packed section and the whole column, we can readily calculate the obstructive factors, such as the porosity and the tortuosity factor, from the measured conductivity ratio. An example is given to demonstrate the application of this method, with experimental data taken from published work.

Journal Article↗

Fluorescence polarization detection for affinity capillary electrophoresis.

Affinity capillary electrophoresis (ACE) with laser-induced fluorescence polarization (LIFP) detection is described, with examples of affinity interaction studies. Because fluorescence polarization is sensitive to changes in the rotational motion arising from molecular association or dissociation, ACE-LIFP is capable of providing information on the formation of affinity complexes prior to or during CE separation. Unbound, small fluorescent probes generally have little fluorescence polarization because of rapid rotation of the molecule in solution. When the small fluorescent probe is bound to a larger affinity agent, such as an antibody, the fluorescence polarization (and anisotropy) increases due to slower motion of the much larger complex molecule in the solution. Fluorescence polarization results are obtained by simultaneously measuring fluorescence intensities of vertical and horizontal polarization planes. Applications of CE-LIFP to both strong and weak binding systems are discussed with antibody-antigen and DNA-protein binding as examples. For strong affinity binding, such as between cyclosporine and its antibody, complexes are formed prior to CE-LIFP analysis. For weaker binding, such as between single-stranded DNA and its binding protein, the single-stranded DNA binding protein is added to the CE separation buffer to enhance dynamic formation of affinity complexes. Both fluorescence polarization (and anisotropy) and mobility shift results are complementary and are useful for immunoassays and binding studies.

Antibodies↗

Synthesis of novel porous magnetic silica microspheres as adsorbents for isolation of genomic DNA.

An improved procedure is described for preparation of novel mesoporous microspheres consisting of magnetic nanoparticles homogeneously dispersed in a silica matrix. The method is based on a three-step process, involving (i) formation of hematite/silica composite microspheres by urea-formaldehyde polymerization, (ii) calcination of the composite particles to remove the organic constituents, and (iii) in situ transformation of the iron oxide in the composites by hydrogen reductive reaction. The as-synthesized magnetite/silica composite microspheres were nearly monodisperse, mesoporous, and magnetizable, with as typical values an average diameter of 3.5 microm, a surface area of 250 m(2)/g, a pore size of 6.03 nm, and a saturation magnetization of 9.82 emu/g. These magnetic particles were tested as adsorbents for isolation of genomic DNA from Saccharomyces cerevisiae cells and maize kernels. The results are quite encouraging as the magnetic particle based protocols lead to the extraction of genomic DNA with satisfactory integrity, yield, and purity. Being hydrophilic in nature, the porous magnetic silica microspheres are considered a good alternative to polystyrene-based magnetic particles for use in biomedical applications where nonspecific adsorption of biomolecules is to be minimized.

Adsorption↗