Accuracy assessment of layer decomposition using simulated angiographic image sequences.

Layer decomposition is a promising method for obtaining accurate densitometric profiles of diseased coronary artery segments. This method decomposes coronary angiographic image sequences into moving densitometric layers undergoing translation, rotation, and scaling. In order to evaluate the accuracy of this technique, we have developed a technique for embedding realistic simulated moving stenotic arteries in real clinical coronary angiograms. We evaluate the accuracy of layer decomposition in two ways. First, we compute tracking errors as the distance between the true and estimated motion of a reference point in the arterial lesion. We find that noise-weighted phase correlation and layered background subtraction are superior to cross correlation and fixed mask subtraction, respectively. Second, we compute the correlation coefficient between the true vessel profile and the raw and processed images in the region of the stenosis. We find that layer decomposition significantly improves the correlation coefficient.

Algorithms↗

X-ray videodensitometric methods for blood flow and velocity measurement: a critical review of literature.

Blood flow rate and velocity are important parameters for the study of vascular systems, and for the diagnosis, monitoring and evaluation of treatment of cerebro- and cardiovascular disease. For rapid imaging of cerebral and cardiac blood vessels, digital x-ray subtraction angiography has numerous advantages over other modalities. Roentgen-videodensitometric techniques measure blood flow and velocity from changes of contrast material density in x-ray angiograms. Many roentgen-videodensitometric flow measurement methods can also be applied to CT, MR and rotational angiography images. Hence, roentgen-videodensitometric blood flow and velocity measurement from digital x-ray angiograms represents an important research topic. This work contains a critical review and bibliography surveying current and old developments in the field. We present an extensive survey of English-language publications on the subject and a classification of published algorithms. We also present descriptions and critical reviews of these algorithms. The algorithms are reviewed with requirements imposed by neuro- and cardiovascular clinical environments in mind.

Algorithms↗

Simulating coronary arteries in x-ray angiograms.

Clinical validation of quantitative coronary angiography (QCA) algorithms is difficult due to the lack of a simple alternative method for accurately measuring in vivo vessel dimensions. We address this problem by embedding simulated coronary artery segments with known geometry in clinical angiograms. Our vessel model accounts for the profile of the vessel, x-ray attenuation in the original background, and noise in the imaging system. We have compared diameter measurements of our computer simulated arteries with measurements of an x-ray Telescopic-Shaped Phantom (XTSP) with the same diameters. The results show that for both uniform and anthropomorphic backgrounds there is good agreement in the measured diameters of XTSP compared to the simulated arteries (Pearson's correlation coefficient 0.99). In addition, the difference in accuracy and precision of the true diameter measures compared to the XTSP and simulated artery diameters was small (mean absolute error across all diameters was < or = 0.11 mm +/- 0.09 mm).

Algorithms↗

Comparison of methods for instantaneous angiographic blood flow measurement.

Several different algorithms have been reported for measurement of blood flow rates and velocities from digital x-ray angiograms. We compare four videodensitometric methods: (1) distance-density curve matching (DDCM), (2) distance-density curve matching with curve-fitting (DDCM-F), (3) bolus mass tracking with curve-fitting (BMT-F) and (4) fluid continuity method (FCM). We tested the flow algorithms with simulated angiograms and with images obtained from a programmable flow phantom under clinically realistic flow and contrast injection conditions including imperfect mixing. All methods perform well for simulated angiograms. On phantom angiograms with constant flow, all methods tended to underestimate flow velocities by at least 7% and demonstrate high variability between consecutive measurements. The FCM demonstrated relatively low variability, but a large negative bias. The DDCM method was moderately biased and had the highest variability. The BMT-F method demonstrated the lowest bias (-7.1%) and the lowest variability both within (27%) and between (27%) studies. No method yields reliable measurements near the peak contrast opacification, when little or no gradient of contrast is present. The extrapolating version of the BMT-F method was also the most robust for estimation of interframe displacements longer than the field of view.

Algorithms↗

Regularization method for scatter-glare correction in fluoroscopic images.

Fluoroscopic images are degraded by scattering of x-rays from within the patient and by veiling glare in the image intensifier. Both of these degradations are well described by a response function applied to either the scatter-free or primary intensity. The response function is variable, with dependence on such factors as patient thickness and imaging geometry. We describe an automated regularization technique for obtaining response function parameters with a minimal loss of signal. This method requires a high-transmission structured reference object to be interposed between the x-ray source and the subject. We estimate the parameters by minimizing residual correlations between the reference object and the computed subject density after a scatter-glare correction. We use simulated images to evaluate our method for both ideal and clinically realistic conditions. We find that the residual root-mean-square (rms) error ideally decreases with an increasing number of independent pixels (N) as (1/N)1/2. In simulated 256x256 angiograms mean normalized rms errors were reduced from 40% to 11% in noise-free images, and from 41% to 17% in noisy images, with a similar improvement in densitometric vessel cross-section measurements. These results demonstrate the validity of the method for simulated images and characterize its expected performance on clinical images.

Angiography↗

Fluid equations applied to blood flow measurement using digital videodensitometry.

RATIONALE AND OBJECTIVES: Time-dependent fluid flow is computed from projection radiographs without bolus tracking by applying the fluid equations of continuity and incompressibility. METHODS: The fluid equations are combined and integrated to yield an equation that describes instantaneous mass conservation within a vessel segment. The technique is demonstrated using phantom images and patient data obtained using a digital subtraction angiography (DSA) system. RESULTS: Instantaneous and mean flow rates are successfully computed with this algorithm, but the uncertainties are overestimated. In a 1.0-cm diameter tube, instantaneous and mean velocities corresponding to 7.3 cm per frame are computed within 13% uncertainty using a 4.0-cm segment length. Mean flow rates computed from standard diagnostic angiograms taken from three different projections agree within 16%. CONCLUSIONS: This technique can successfully compute time-dependent flow rates from DSA image sequences with large fluid displacements between frames. The accuracy is strongly dependent on the magnitude of the contrast density gradient.

Algorithms↗

The management of ruptured intracranial aneurysm in sickle cell anemia. Case report.

The problems of sickle cell disease and its complications is discussed. Subarachnoid hemorrhage is not a common complication of sickle cell disease and should be evaluated in the same way as if it were not associated with the disease. Patients with sickle cell trait have an added risk during angiography and hypotensive anesthesia. Guidlines are given for angiography and craniotomy with hypotensive anesthesia and reduction of brain volume in these patients.

Anemia, Sickle Cell↗

Arteriovenous malformation: a 22-year angiographic follow-up.

A case is reported of an unoperated giant arteriovenous malformation with a progressive deterioration ending in a severe dementia and invalidism. Angiographic documentation is over a 22 year interval. The presentation, diagnosis and treatment of this disease are discussed. It is concluded that early surgical intervention should have a primary role in the management of giant arteriovenous malformation.

Cerebral Angiography↗

The determination of speech organization in a patient with an arteriovenous malformation.

A case is reported of an arteriovenous malformation in the left motor speech area which was successfully excised without aphasia in a right-handed man. Preoperative sodium amobarbital carotid infusion testing demonstrated that the patient had right hemisphere dominance for speech. A review of the literature suggests that this is not an uncommon occurrence in individuals with congenital lesions of the left cerebral hemisphere. Lateralization of speech dominance should be established through definitive testing in these cases, especially if surgical removal of the malformation is contemplated.