PubMed Health⌕ Search

PubMed · 10505866

Regularization method for scatter-glare correction in fluoroscopic images.

Abstract

Fluoroscopic images are degraded by scattering of x-rays from within the patient and by veiling glare in the image intensifier. Both of these degradations are well described by a response function applied to either the scatter-free or primary intensity. The response function is variable, with dependence on such factors as patient thickness and imaging geometry. We describe an automated regularization technique for obtaining response function parameters with a minimal loss of signal. This method requires a high-transmission structured reference object to be interposed between the x-ray source and the subject. We estimate the parameters by minimizing residual correlations between the reference object and the computed subject density after a scatter-glare correction. We use simulated images to evaluate our method for both ideal and clinically realistic conditions. We find that the residual root-mean-square (rms) error ideally decreases with an increasing number of independent pixels (N) as (1/N)1/2. In simulated 256x256 angiograms mean normalized rms errors were reduced from 40% to 11% in noise-free images, and from 41% to 17% in noisy images, with a similar improvement in densitometric vessel cross-section measurements. These results demonstrate the validity of the method for simulated images and characterize its expected performance on clinical images.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R A Close, K C Shah, J S Whiting. 1999. Regularization method for scatter-glare correction in fluoroscopic images.. https://doi.org/10.1118/1.598683

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transhepatic vascular access for diagnostic and interventional procedures: techniques, outcome, and complications.

Early or multiple cardiac catheterizations may result in occlusion of the femoral veins prohibiting their use. The internal jugular or sub-clavian approach may be an appropriate alternative. However, these approaches may not be suitable in patients with surgical interruption of the superior vena cava. In other patients, they may not allow easy access to certain areas of the heart. The transhepatic approach is an important alternative route for performing cardiac catheterization and interventions. Depending on the planned procedure, it may be the preferred route to perform the cardiac catheterization even in the presence of patent femoral veins. The indications, technical details and potential complications of this approach are discussed.

Angiography↗

Embolization for a bleeding pelvic fracture in a patient with persistent sciatic artery.

Emergency embolization for a bleeding pelvic fracture was performed in a patient with persistent sciatic artery, a rare anatomic variation in which the internal iliac artery continues to the popliteal artery. Successful hemostasis was achieved without complications by means of selective catheterization into each branch of the internal iliac artery. Awareness of this unusual vascular anatomy is critically important to avoid serious complication of emergency embolization.

Angiography↗