Single- versus dual-chamber sensor-driven pacing: comparison of cardiac outputs.

Previous studies have shown that single-chamber sensor-driven pacing improves exercise tolerance for patients with chronotropic incompetence. However, long-term single-chamber pacing has a number of inherent problems that limit its usefulness. Although sensor-driven dual-chamber pacing largely obviates the problems inherent with single-chamber sensor-driven pacing, the physiologic benefit of dual-chamber sensor-driven pacing has not yet been demonstrated. Accordingly, the purpose of this study was to compare exercise-induced cardiac output for patients with chronotropic incompetence, after programming their pacemakers to either a simulated sensor-driven single or simulated dual-chamber mode. Cardiac output was measured noninvasively at rest and peak exercise using standard Doppler-derived measurements, obtained in a blinded fashion. At rest the Doppler-derived resting VVI and DDD cardiac outputs were 4.49 +/- 0.3 L/min and 4.68 +/- 0.3 L/min, respectively. At peak exercise, the DDD cardiac output was 5.07 +/- 0.5 L/min, whereas the simulated activity VVI and DDD cardiac outputs were 6.33 +/- 0.6 L/min and 7.41 +/- 0.70 L/min, respectively. Analysis of variance showed that there was an overall significant difference in cardiac output from rest to peak exercise (p less than 0.001). However, only the simulated activity DDD cardiac output was significantly different from its respective control value (p less than 0.05). Thus this study shows for the first time that the addition of rate responsiveness to dual-chamber pacing results in a significant improvement in cardiac output for patients with chronotropic incompetence.

Aged

Catheter-induced tricuspid regurgitation. Incidence and clinical significance.

The incidence and severity of catheter-induced tricuspid regurgitation has not been studied extensively. Given the frequency with which right heart catheters are employed to measure cardiac output, it is important to know whether the severity of catheter-induced tricuspid regurgitation is sufficient to invalidate the measurement of thermodilution cardiac output. Accordingly, the purpose of the present prospective study was to determine the incidence and severity of catheter-induced tricuspid regurgitation in 25 men (mean age, 58.1 +/- 1.4 years) using Doppler ultrasound. The tricuspid valve was interrogated from two orthogonal views using pulsed-wave and color flow Doppler, either in the presence or absence of a 7-French catheter across the tricuspid valve. The severity of catheter-induced tricuspid regurgitation was graded semiquantitatively using a validated scoring system. Pulsed-wave Doppler studies showed that the incidence of catheter-induced tricuspid regurgitation was 48 percent, and that the average tricuspid regurgitation score increased from 0.41 +/- 0.16 to 0.61 +/- 0.17 (p less than 0.01). Color flow Doppler studies showed similar findings. Further, the incidence of catheter-induced tricuspid regurgitation was not related to the patient's underlying hemodynamic status or right ventricular geometry. In conclusion, this study shows for the first time that the quantitative extent of catheter-induced tricuspid regurgitation is small, and is therefore unlikely to be important clinically, particularly with regard to the assessment of thermodilution cardiac output.

Cardiac Catheterization

Prosthetic valve endocarditis due to Cardiobacterium hominis occurring after upper gastrointestinal endoscopy.

Bacterial endocarditis secondary to endoscopic procedures has been convincingly documented in only four cases. We describe a case of prosthetic valve endocarditis due to Cardiobacterium hominis that developed after upper gastrointestinal endoscopy. Because of this, we recommend subacute bacterial endocarditis prophylaxis in patients who have a prior history of endocarditis or valve replacement.

Aortic Valve

Programming eccentricities of an activity sensing pacemaker.

The Activitrax rate responsive pacemaker system has enjoyed wide popularity but minor engineering eccentricities have occurred and have been reported. We report another unusual feature seen in Activitrax models 8400, 8402, and 8403. This feature consists of continuing in a temporary mode while a different permanent mode was programmed. These eccentricities of the programming features are not very commonly seen, however, they can be somewhat perplexing to the physician following the patient. These unusual features are no longer present in the newer models being manufactured.

Biomedical Engineering

The potential utility of sensor-driven pacing in DDD pacemakers.

Sensor-driven pacemakers have clinically improved symptomatology over ventricular pacemakers. Adding rate responsiveness to DDD pacing would theoretically benefit patients with an inability to increase their atrial rate. We evaluated 20 patients who had long-term implanted DDD pacemakers as to the utility of an added effect of rate responsiveness. The pacemakers had been implanted for an average of 34 months. This patient group included 15 patients with atrioventricular (AV) block and five patients with sick sinus syndrome. All patients were exercised on the treadmill until they were fatigued and were monitored to determine their intrinsic heart rate response. A sensor-driven pacemaker was strapped to the patients and was connected to an ECG to measure its rate response. It was set to activity threshold of medium, with a rate response of 7. The 20 patients exercised for an average of 5.9 minutes, with a range of 1.7 to 10 minutes. The maximum intrinsic atrial response averaged 110 beats/min, ranging from 60 to 150 beats/min. The maximum achieved activity rate averaged 99 beats/min, ranging from 60 to 118 beats/min. In 7 of the 20 of patients (35%), the activity pacemaker reached a higher rate than the patient's intrinsic rate. Six had AV block and one had sick sinus syndrome. In these seven patients the peak activity rate response averaged 102 beats/min and their intrinsic activity averaged to 78 beats/min. There was an increase in rate by the addition of rate responsiveness in 35% of our DDD patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Supernormal ejection performance is isolated to the ipsilateral congenitally pressure-overloaded ventricle.

Congenital left ventricular pressure overload is associated with "excessive" hypertrophy that leads to subnormal afterload (wall stress), permitting enhanced ventricular ejection performance. Whether congenital right ventricular pressure overload is associated with a similar phenomenon is uncertain. It is also unknown whether supranormal ejection performance affects only the overloaded ventricle or is a general process affecting both ventricles. Conflicting data exist about whether the hypertrophic process associated with pressure overload is induced primarily by local loading conditions or by neuroendocrine influences. If the former postulate is true, the hypertrophic response should be confined to the overloaded ventricle; if the latter is true, one might predict that both ventricles would be affected by a less specific response to circulating catecholamines. To help resolve these issues, both right and left ventricular performance was examined in seven patients with isolated congenital pulmonary stenosis (average pulmonary pressure gradient 78 +/- 13 mm Hg), six patients with isolated congenital aortic stenosis (average gradient 80 +/- 10 mm Hg) and six normal subjects. Right ventricular ejection fraction was increased in patients with pulmonary stenosis (61 +/- 2%) compared with the value in normal subjects (53 +/- 2%, p less than 0.01) and in patients with aortic stenosis (50 +/- 3%, p = 0.007). Left ventricular ejection fraction was increased in patients with congenital aortic stenosis (84 +/- 4%) compared with the value in normal subjects (70 +/- 4%, p less than 0.01) and in patients with congenital pulmonary stenosis (65 +/- 2%, p less than 0.002).(ABSTRACT TRUNCATED AT 250 WORDS)

Aortic Valve Stenosis

Comparison of lead dislodgment and pocket infection rates after pacemaker implantation in the operating room versus the catheterization laboratory.

To assess and compare the rates of lead dislodgment and pocket infection in patients having procedures performed in the operating room versus those performed in the cardiac catheterization laboratory, we reviewed the records of 85 adult patients who underwent 88 procedures, all performed by one surgical team and having complete follow-ups at our institution from October 8, 1979, through November 7, 1986. Forty-five patients underwent 46 procedures in the operating room, and 40 patients underwent 42 procedures in the cardiac catheterization laboratory. There was one instance of ventricular lead dislodgment noted among the 48 leads implanted in the operating room and one instance of ventricular lead dislodgment among the 58 leads implanted in the cardiac catheterization laboratory. No instances of atrial lead dislodgment were noted. No instances of pocket infection were noted among the 46 procedures performed in the operating room or in the 42 procedures performed in the cardiac catheterization laboratory. We conclude that pacemaker implantation can be performed with equivalent safety and effectiveness in the cardiac catheterization laboratory and in the operating room.

Adult

Pacemaker follow-up and adequacy of Medicare guidelines.

The time of occurrence of cardiac pacemaker problems after implantation was identified to assess the adequacy of published federal guidelines for clinic and transtelephonic follow-up. One hundred eighty-nine pacemaker patients' charts were examined retrospectively to identify pacemaker problems: inadequate sensing, non-capture, battery failure, myoinhibition, muscle stimulation, and inadequate threshold safety margin. Twenty-nine patients (15%) were identified as having pacemaker problems. A total of 41 problems were identified, of which 28 (68%) were corrected by reprogramming. Sixty-one percent of the problems were found during a clinic visit. Problems occurred more frequently during the first year in dual-chamber devices (62%) vs single-chamber devices (35%). During years 1 to 4, when few problems are expected, 30% of all problems of single-chamber devices occurred and 39% of all problems of dual-chamber devices occurred. This is a period of time that Medicare guidelines allow for one clinic visit per year for single- and two visits per year for dual-chamber devices. These data suggest: (1) Many pacemaker problems will be missed with transtelephonic follow-up alone. (2) The majority of problems involving dual-chamber devices occurred in the first year. (3) For both dual- and single-chamber devices, an unexpected significant percentage of problems occurred in 1 to 4 years. (4) Medicare guidelines may be inadequate for follow-up during this time period.

Adult

Effect of data collection method on results of serum digoxin concentration audit.

The appropriateness of serum digoxin concentration (SDC) orders was evaluated with respect to indication for use, sampling time, and action taken by physicians when the reported SDC was out of the normal therapeutic range; the effect of the two data-collection methods used (retrospective and concurrent audits) on the results was studied. Criteria for the appropriate use of SDCs were approved by the medical staff through the pharmacy and therapeutics committee. Patients on adult medicine services were entered into the study as daily SDC determinations were reported by the clinical laboratory. Most of the SDCs were evaluated using approved criteria by primary pharmacist clinicians who were concurrently monitoring drug therapy and participating with the treatment team. A retrospective audit of the same patients was conducted, using only chart review. A total of 134 SDCs involving 78 patients were evaluated. Concurrent-audit results indicated that 18.7% of the SDCs were ordered without an appropriate indication, 16.4% were sampled incorrectly with respect to proper timing, and 8.2% did not result in dosage adjustments when indicated. With respect to appropriate sampling time and overall use of SDCs, significantly more SDCs met the standards under concurrent audit than under retrospective audit. The retrospective chart review method of auditing may not detect as much pertinent information as is desirable.

Concurrent Review

Efficacy and safety of sustained-release diltiazem as replacement therapy for beta blockers and diuretics for stable angina pectoris and coexisting essential hypertension: a multicenter trial.

To determine if a sustained-release form of the calcium entry blocker diltiazem would be a satisfactory substitute for the combination of beta-adrenergic blocking agent and thiazide diuretic in the treatment of systemic hypertension and angina pectoris, 38 patients were studied in a 4-center trial. Blood pressure and heart rate were measured in the supine position, immediately after and 5 minutes after standing. Modified Bruce protocol treadmill tests were performed to determine the time to onset of 1 mm ST-segment depression, time to onset of chest pain and time to termination of exercise. Diltiazem monotherapy resulted in equivalent blood pressure control in 28 of 38 patients (74%). In the remaining patients, blood pressure control was achieved with resumption of the diuretic. Blood pressure with beta blocker plus diuretic compared with diltiazem were, in the supine position 137 +/- 22/82 +/- 7 (+/- 1 standard deviation) versus 139 +/- 22/82 +/- 8 mm Hg, immediately after standing 131 +/- 20/84 +/- 9 versus 133 +/- 21/82 +/- 10 mm Hg and after standing for 5 minutes 134 +/- 19/85 +/- 8 versus 137 +/- 18/85 +/- 9 mm Hg (difference not significant for each). The heart rate with diltiazem was higher supine (67 +/- 11 versus 60 +/- 11 beats/min), standing (73 +/- 13 versus 64 +/- 14 beats/min) and 5 minutes after standing (73 +/- 14 versus 63 +/- 14 beats/min, p less than 0.01 for each).(ABSTRACT TRUNCATED AT 250 WORDS)

Adrenergic beta-Antagonists

Predictors of outcome for aortic valve replacement in patients with aortic regurgitation and left ventricular dysfunction: a change in the measuring stick.

Although left ventricular function is generally regarded as a key determinant of prognosis in aortic regurgitation, predictors of outcome of aortic valve replacement based on this factor have recently been questioned. This study was performed to examine the role of indexes of left ventricular function in predicting the outcome of surgery in patients with aortic regurgitation and left ventricular dysfunction. Fourteen patients with aortic regurgitation with a preoperative ejection fraction of less than 0.55 (average 0.45 +/- 0.02) who underwent aortic valve replacement were studied. The patients had 82 (58%) of a possible 140 predictors of negative outcome preoperatively, but 12 of the 14 patients had a decrease in symptoms and an increase in ejection fraction into the normal range after operation (average postoperative ejection fraction 0.59 +/- 0.04). Although improvement occurred despite the presence of many negative predictors of outcome, there was a significant correlation between postoperative ejection fraction and eight of the tested preoperative predictors. Preoperative end-systolic dimension correlated best (r = -0.91) with postoperative ejection fraction. An end-systolic dimension of 60 mm correlated with a postoperative ejection fraction of 0.55. The results indicate that preoperative ventricular function is still an important determinant of outcome of aortic valve replacement for aortic regurgitation. However, current medical and surgical techniques permit a better prognosis in the presence of reduced ventricular function than was previously considered possible.

Aortic Valve Insufficiency

Lack of apparent effect of assay methodology on the pharmacokinetics of digoxin.

The purpose of this study was to determine if serum digoxin concentration data using three different automated immunoassay methods would produce similar pharmacokinetic values in normal volunteer subjects. Area under the curve (AUC), steady-state volume of distribution/bioavailability ratio (Vd/F), terminal elimination rate constant (beta), clearance/bioavailability ratio (CL/F), maximum digoxin concentration (Cmax), minimum digoxin concentration (Cmin), and time of peak (Tp) were evaluated. Ten healthy volunteers received digoxin capsules 0.2 mg daily for 10 days. On day 10, 16 serial blood samples were collected over a 24-h dosing interval and analyzed by radioimmunoassay (RIA) (Concept 4, Micromedic Systems), fluorescence polarization immunoassay (FPIA) (TDx, Abbott Laboratories), and affinity column-mediated immunoassay (ACMIA), (aca, duPont Instruments). When comparing RIA and FPIA, the mean of the percent differences for AUC, Vd/F, beta, and CL/F were 9, 4, 10, and 6%, respectively. The mean of the percent differences were 2, 3, 44, and 6%, respectively, when comparing RIA and ACMIA. However, none of these differences were statistically significant. Although a trend toward higher Cmax values by RIA was noted, there was no statistical difference in Cmax, Cmin, and Tp. Orthogonal regression of all serum digoxin concentrations showed that FPIA = 0.76 RIA + 0.19, r = 0.967 (p less than 0.001); and ACMIA = 0.92 RIA + 0.04, r = 0.943 (p less than 0.001). At serum digoxin concentrations less than 1 ng/ml, FPIA overestimated RIA results (p less than 0.005), while ACMIA was approximately equal to the RIA results.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Proteins

Limitations of the long-term clinical application of rate hysteresis.

Rate hysteresis is the ability of a pacemaker to pace at an automatic rate that is different from the escape rate. We reviewed our experience with this programmable feature and its utility. The long-term clinical application of rate hysteresis was limited due to the development of atrial fibrillation or to slowing of the intrinsic cardiac rhythm in 27.6% of the 29 patients. Since many patients with sick sinus syndrome have preserved AV conduction, one might expect that these patients would have an adequate intrinsic heart rate to allow successful use of rate hysteresis pacing mode. Sick sinus syndrome was the intrinsic rhythm disturbance in 63% of the group requiring discontinuation of rate hysteresis. These patients may represent a subgroup in whom any theoretical advantages provided by the rate hysteresis feature may be outweighed by the propensity for the development of atrial fibrillation or significant slowing of the intrinsic rhythm.

Aged

An argument for pacemaker reuse: pacemaker mortality in 169 patients over ten years.

Retrospective examination of 169 consecutive pacemaker patient deaths was done to test the hypothesis that early mortality would preclude full utilization of current battery longevity. We found a 58% mortality within two years of the last generator implant. Nineteen percent occurred within six months, and 38% occurred within a year. This compares to a current clinic of 246 patients where 43% have utilized these pacemakers for greater than 48 months. The age comparison shows that those who died were older than the living controls. The 58% 24-month mortality demonstrates that many patients underutilize expected battery life. The economic implications of pacemaker reuse can then be understood.

Aged