PubMed Health⌕ Search

Biomedical subjects

R Brüning

Publications and source records attributed to R Brüning.

At least 55 records · Page 3Linked to original sources

[Methods of quantification of coronary artery calcifications with electron-beam and conventional computed tomography].

PURPOSE: To compare electron beam CT (EBCT) und prospectively ECG gated conventional CT for the detection and quantification of coronary artery calcifications. METHODS: 42 patients (mean age 62.8 +/- 8.8 years) were scanned, both with EBCT and ECG gated sequential CT. For quantification, the traditional "total calcium score" (TCS) according to the Agatson method as well as the "volumetric calcium score" (VCS) as determined with a stand-alone workstation (NetraMD) was calculated for both modalities. RESULTS: There was close correlation between EBCT and conventional CT, both for TCS (r = 0.984) as well as for VCS (r = 0.986) score values. The median difference was 17% for TCS and 13% for VCS. The difference between the two modalities was not statistically significant (p = 0.44). CONCLUSION: EBCT and prospectively ECG triggered conventional CT are equivalent for the quantification of coronary artery calcifications. The extent of calcifications can be established with both modalities using either TCS or VCS score values.

Age Factors↗

[Significance of electron-beam tomography in the evaluation of the patency of aortocoronary bypasses].

PURPOSE: Electron beam tomography (EBT) permits acquisition of images with high spatial and temporal resolution. The value of EBT and other imaging modalities for the depiction of patent coronary artery bypass grafts (ACVB, IMA) are compared to coronary angiography and an overview of current results is given. MATERIAL AND METHODS: Graft patency can be evaluated with indirect methods stress, such as echocardiography, radionuclide ventriculography, myocardial scintigraphy, positron-emission tomography (PET) and direct imaging modalities, such as Doppler/2D echocardiography, EBT, spiral computed tomography (SCT) and magnetic resonance angiography (MRA). RESULTS: With indirect methods graft patency can be evaluated with sensitivity of 64-100% and specificity of 73-100%. EBT and SCT are equivalent in sensitivity (= 94%) in the assessment of open venous grafts and specificity is up to 100%, but EBT is superior in the diagnosis of patent IMA grafts (sensitivity 100% vs 89%). Visualization of high-grade venous bypass stenosis seems possible with EBT. MRA with gradient echo technique is highly accurate in the assessment of patent venous grafts (sensitivity 77-93%) but has limited value in the evaluation of IMAs (sensitivity = 53%). Promising are ultrafast 3D-MRA methods which permit high accuracy (sensitivity = 94-96%) in assessing venous and arterial grafts. DISCUSSION: Indirect imaging methods cannot differentiate between an occluded bypass, progression of coronary artery disease and myocardial infarction. EBT and SCT are equivalent in the diagnosis of open and occluded venous grafts, but EBT is superior in the assessment of patent IMA grafts. Visualization of high-grade venous bypass stenosis seems possible with EBT. MRA techniques, especially ultrafast 3D-MR methods, are highly accurate in the assessment of patent venous and arterial grafts but are still limited to scientific research.

Coronary Artery Bypass↗

[Functional imaging of the heart with electron-beam computed tomography].

PURPOSE: Electron-beam computed tomography (EBCT) enables examinations with a very short acquisition time of 50 ms and thus permits cardiac imaging without motion artifacts. Utilizing eight detector rings simultaneous image acquisition in up to eight levels and complete imaging of the whole heart is possible. In studies, functional imaging with EBCT was compared to our angiocardiography, echocardiography, radionuclide, ventriculography and magnetic resonance tomography. MATERIALS AND METHODS: ECG-triggered long- and short-axis cine studies were performed with the Imatron C-150 Evolution, acquiring 160 and 156 images at 8 and 12 levels. After manual tracing of epicardial and endocardial borders, ventricular size, ejection fraction, wall-thickening and myocardial mass were calculated. RESULTS: A very high correlation between EBCT and direct determination of right and left ventricle (r = 0.98 and r = 0.99) was demonstrated. Compared to echocardiography, angiocardiography and radionuclide ventriculography, assessment of ventricular function was more precise and more reliable. DISCUSSION: EBCT allows the exact and reliable determination of left and right ventricular function. Also precise assessment of myocardial mass is possible. However, the high radiation exposure and diagnostic effort have to be considered.

Angiocardiography↗

[Calculation of absolute cerebral blood volume and cerebral blood flow by means of electron-beam computed tomography (EBT) in acute ischemia].

The utility of electron beam computed tomography (EBT) to estimate cerebral blood volume (CBV) and cerebral blood flow (CBF) was evaluated. Eleven patients with suspected acute cerebral ischemia were investigated. The EBT was performed with an acquisition time of 50 ms per slice at eight parallel levels. To compare signal/noise and contrast/noise ratios the data from the EBT investigation were compared to a similar examination on a spiral CT. The signal/noise ratio with EBT was about 30%, the contrast/noise ratio 25% of that with spiral CT. The absolute values of CBV were 4.9 +/- 1.2 ml/100 g (EBT); CBF was 50.5 +/- 7.0 ml/100 g/min in normal contralateral brain tissue. In four patients with proven infarcts on follow-up, the ischemic areas had a CBV ranging from 1.7 to 3.8 ml/100 g, while CBF ranged from 9.4 to 24.5 ml/100 g/min. Using a bolus injection of contrast material, calculation of absolute CBV and CBF is feasible using EBT. Advantages of EBT are the absolute measurements possible and it's multislice capability. Disadvantages, however, are caused by the high image noise, limiting the demarcation of ischemic tissue.

Acute Disease↗

Common variable immunodeficiency leading to spinal subacute combined degeneration monitored by MRI.

A patient is reported on with a common variable immunodeficiency syndrome (CVID), in whom chronic gastritis with antibodies against parietal cells and a cytomegalovirus associated enteritis led to vitamin B12 deficiency with consecutive subacute combined degeneration of the spinal cord. The resulting medullary changes, most probably representing demyelination, were visualised with MRI. The effects of treatment were also monitored over three years by MRI and clinical examination. The resolution of the MRI changes correlated with clinical improvement of the patient's signs. In the medical literature only five cases of vitamin B12 related spinal cord changes have been identified by MRI; none was caused by a CVID syndrome.

Autoimmune Diseases↗

Diffusion-weighted MR imaging of bone marrow: differentiation of benign versus pathologic compression fractures.

PURPOSE: To evaluate the usefulness of diffusion-weighted magnetic resonance (MR) imaging of bone marrow for differentiating between benign and pathologic vertebral compression fractures. MATERIALS AND METHODS: Thirty patients with 39 vertebral compression fractures were examined with MR imaging. Diffusion-weighted MR imaging was performed with a steady-state free precession sequence in 22 acute benign osteoporotic and/or traumatic fractures and 17 pathologic compression fractures. Biplanar radiographs, T1-weighted spin-echo (SE) MR images, and short inversion time inversion-recovery (STIR) MR images were available for all patients. The signal intensity characteristics were analyzed qualitatively and quantitatively (bone marrow contrast ratios and signal-to-noise ratios) for all sequences. RESULTS: At diffusion-weighted MR imaging, all benign vertebral compression fractures were hypo- to isointense to adjacent normal vertebral bodies. Pathologic compression fractures were hyperintense to normal vertebral bodies. Benign vertebral fractures had negative bone marrow contrast ratios at diffusion-weighted imaging, whereas pathologic vertebral fractures had positive values (P < .001). The difference in bone marrow contrast ratios for benign and pathologic compression fractures at T1-weighted SE and STIR imaging was not significant (P > .01). CONCLUSION: Diffusion-weighted MR imaging provided excellent distinction between pathologic and benign vertebral compression fractures.

Adult↗

Diffusion measurements in the ischemic human brain with a steady-state sequence.

RATIONALE AND OBJECTIVES: The authors evaluate the clinical usefulness of a diffusion-weighted steady-state free-precession (SSFP) sequence to detect acute and subacute ischemic changes. METHODS: Twenty-four patients were examined on a 1.5-tesla scanner, using a SSFP-sequence (repetition time [TR]/ echo time [TE] = 22/3-8 mseconds). The slice thickness was 5 mm, 10 averages, 57 seconds per slice. The diffusion gradient strength was 23 millitesla/m, with b-values from 165 to 598 seconds/mm2. Diffusion-weighted images (DWI) were compared with T2-weighted images. RESULTS: The diffusion-weighted SSFP sequence produced diagnostic quality images in 23 of 24 patients. Diffusion depicted (group 1: 0-12 hours) more acute lesions (3 of 6) than T2-weighted images (2 of 6); the mean lesion diameter depicted by diffusion was 10.9 mm (standard deviation [SD], 12.3) and in T2-weighted images was 4.7 mm (SD 6.8). A significant correlation (P < 0.017) in subacute lesions was found when diffusion was compared with turbo spin echo (mean size difference/T2 = 18.5/17.5 mm, SD 13.2/12.2). CONCLUSIONS: The diffusion-weighted SSFP-sequence is more sensitive in acute ischemia and delineates likewise in subacute ischemia, when compared with T2-weighted imaging.

Adult↗

[Functional magnetic resonance tomography of the visual cortex].

Functional magnetic resonance imaging (MRI) allows to directly visualize regional activity of the visual cortex during stimulation. The value of the method to evaluate physiologic and pathologic conditions is elaborated on in comparison with positron emission tomography (PET). Aspects as sequence selection and stimulus paradigms are discussed. Subtle activity in the primary cortex (V1), processing areas as MT/V5 and subcortical areas are visualized by MRI. Cooperation of the subjects is a essential factor. Despite promising initial results in clinical trials the focus of research in clinical trials the focus of research in the visual cortex yet remains in the preclinical field.

Animals↗

[Echo-planar imaging of the brain].

In this review, the clinical utility of echoplanar techniques in MRI of the brain is discussed. Comparison of high-resolution EPI with SE/turbo-SE shows high image quality of EPI in the supratentorial brain. In the infratentorial region, however, susceptibility artifacts limit image quality. For the assessment of neuronal brain activation utilizing the intrinsic contrast of blood (BOLD), EPI has definite advantages over other techniques of functional MRI. Due to its superior temporal resolution and multislice capabilities, EPI allows for analysis of complex neuronal activation patterns. Diffusion imaging benefits from the lack of bulk motion artifacts and serves primarily to detect early stroke. Three methods of perfusion imaging (rel. blood volume, rel. blood flow) are discussed: the susceptibility artifact method (T2*), the relaxitivity method (T1), and the signal-labelling technique (STAR). Perfusion imaging may have a clinical impact in the assessment of brain tumors and cerebral ischemia.

Artifacts↗

[3-D CT reconstruction of fractures of the skull base and the facial skeleton].

3-D reconstructions of the skull base, temporal bone, and skull fractures were compared to 2-D- CT to evaluate the diagnostic value in traumatized patients. 38 patients with 22 fractures of the facial skeleton (orbita, zygomatic, Le Fort), 12 temporal bone, and 4 skull fractures were investigated. Subjective grading was performed by two physicians (ENT/RAD) in respect of quality diagnostic validity and estimated clinical impact. The average image validity and quality were graded good. In the temporal bone the average information supplied by 3-D was of inferior value; here, the lack of information regarding the inner ear structures was responsible for the lack of clinical impact. In fractures of the facial skeleton and the skull base a good to very good image quality was seen and clinical relevance was high. 3-D CT is capable of demonstrating fractures, which is of little value in the temporal bone, but of high value in the skull base and the facial skeleton, especially if surfaces are involved or fragments are displaced.

Facial Bones↗

[Fat-suppressing STIR sequences with and without contrast media in the MRT of ENT tumors].

Fat-suppressed STIR (short TI inversion recovery) sequences were compared to plain and contrast-enhanced T1-weighted SE sequences of head and neck tumors. 19 patients underwent MR imaging on a 0.5 Telsa system (T5-II, Philips). STIR imaging parameters: TR/TE = 1000/20 ms, inversion pulse 100 ms. All films were read by four radiologists. The image quality was graded: score from 0 to 5, by means that grade 5 = optimal quality. Sensitivity was 89% in STIR, 96% in SE sequences. Tumor delineation was graded good in the enhanced T1-weighted and enhanced fat suppression images. The unenhanced imaging was superior in STIR (STIR/T1 = 2.8/2.43). The tumor contrast was best in contrast enhanced and plain STIR sequences (STIR contrast = 3.41), and in the contrast enhanced T1-weighted SE (3.33). STIR almost equaled T1 post-contrast in respect of tumour conspicuity, but the sensitivity was lower. STIR can be a supplement to SE, but cannot substitute T1 postcontrast. The combined use is expected to have the highest assessment value.

Adipose Tissue↗

[Rheumatoid arthritis of the wrist. Dynamic Gd-DTPA enhanced MRT].

21 patients with rheumatoid arthritis of the wrist diagnosed according to the criteria of the American Rheumatism Association were examined by dynamic MRT before and after the i.v. injection of Gd-DTPA (0.1 mmol/kg). The results were correlated with the clinical and radiological findings. The increased signal intensity of the pannus was 1.17 +/- 0.45%/sec and this differed significantly (p < 0.001) from bone marrow (0.16 +/- 0.11%/sec) and from muscle (0.25 +/- 0.16%/sec). Blood sedimentation rate correlated with the gradient of synovial proliferation (p < 0.05). There were no further statistically significant correlations between the clinical, radiological and MRT findings and the change in signal intensity from synovial proliferation as shown by dynamic MRT.

Adult↗