A system oriented electrocardiographic amplifier.

A low noise, programmable gain amplifier has been developed for acquiring ECG data from a variety of recording environments. Features include: low noise (4muV peak-to-peak) differential inputs; digitally programmable gains (range 100 to 16000) and output DC offsets (range -3.5 to +4 V) controlled via a serial interface; externally selectable low frequency response (0.04 or 0.08 Hz); and an on-board output monitor multiplexer controlled via a second serial interface.

Amplifiers, Electronic

Left precordial isopotential mapping during supine exercise.

Junctional depression is often observed during physical exercise in overtly normal subjects. To explore its pathogenesis, 15 normal volunteers were studied during supine, bicycle ergometer, submaximal stress tests. Electrocardiograms were simultaneously recorded from 42 electrodes on the left anterior precordium at two minute intervals at rest and during exercise. Data were used to construct isopotential maps throughout the P-QRS-T intervals. At rest, maps throughout the ST segment were dominated by a single maximum along the upper left sternal border. During exercise, all subjects developed junctional depression that was maximal along the lower left sternal border. Exercise maps during the early to mid-ST segment showed an intense minimum along the lower left sternal border that was continuous with terminal QRS forces in both intensity and location. Later in ST, this minimum decreased in strength and was replaced by a maximum located in the same area as that observed at rest. These observations suggest that junctional depression is the result of competition between two effects, one being normal repolarization which is obscured in the early ST segment by the second, possibly representing delayed terminal depolarization forces.

Action Potentials

Detection and localization of multiple epicardial electrical generators by a two-dipole ranging technique.

The ability of a numerical procedure to detect and to localize two experimentally induced, epicardial dipolar generators was tested in 24 isolated, perfused rabbit heart preparations, suspended in an electrolyte-filled spherical tank. Electrocardiograms were recorded from 32 electrodes on the surface of the test chamber before and after placement of each of two epicardial burns. The second lesion was located either 180 degrees, 90 degrees, or 45 degrees from the first. Signals were processed by iterative routines that computed the location of one or two independent dipoles that best reconstruced the observed surface potentials. The computed single dipole acounting for 99.68% of root mean sequare (RMS) surface potential recorded after the first burn was located 0.26 +/- 0.10 cm from the centroid of the lesion. Potentials recorded after the second lesions were fit with two dipoles that accounted for 99.36 +/- 1.51% of RMS surface potentials and that were located 0.42 +/- 0.26 cm and 0.57 +/- 0.49 cm from the centers of the corresponding burn. Seventy-one percent of computed dipoles were located within the visible perimeter of the burn. Thus, two simultaneously active dipolar sources can be detected and accurately localized by rigorous study of the generated electrical field.

Animals