Amino acid clusters formed by sonic spray ionization.

A novel ion source based on the principle of sonic spray ionization has been built and used to optimize mass spectrometric conditions for generating amino acid clusters. The ion source employs a simple pneumatic spray operated at extremely high nebulizing gas flow rates. Several factors that affect the performance of the cluster source are identified, and information from these observations provides insights into the mechanisms of gas phase ion formation. Serine is used as a model system in optimizing instrumental and sample parameters to maximize cluster ion formation. The sonic spray results for this oligomer compare favorably with electrospray data, showing an order of magnitude better signal intensity and excellent signal-to-noise ratios. The performance of the system for the protonated serine octamer includes a limit of detection of 10 nM and a linear dynamic range of 4 orders of magnitude. Ion formation was observed to go into saturation above 1 mM. This result and data on pH, electrolyte concentration, and solvent composition are interpreted as supporting a charge residue model of sonic spray ionization. Other amino acids can be substituted for serine in the octamer, with a strong chiral preference in favor of homochiral cluster formation in the cases of threonine and cysteine. These amino acids show a preference for substitution of more than two serine molecules. Phenylalanine, asparagine, tryptophan, and tyrosine also substitute into the serine octamer; however, the process yields only two incorporations and only small chiral effects.

Amino Acids↗

Chiral analysis using the kinetic method with optimized fixed ligands: applications to some antibiotics.

A new version of the kinetic method for chiral analysis, which employs a fixed (nondissociating) ligand as well as the usual analyte and chiral reference ligands, is introduced to simplify the kinetics of this experiment. Singly charged clusters containing the divalent transition metal ion MnII, a peptide which serves as a fixed ligand, an amino acid chiral reference, and the analyte 4-benzyl-2-oxazolidinone were generated by electrospray ionization (ESI). The cluster ion of interest was mass-selected, and the kinetics of its competitive unimolecular dissociations was investigated in an ion trap mass spectrometer. The chiral selectivity (R(fixed)chiral), the ratio of the two fragment ion abundances when the cluster contains one pure enantiomer of the analyte expressed relative to that for the other enantiomer, varies with increasing size of the fixed peptide ligands. The metal-ligand and the ligand-ligand interactions that produce chiral discrimination are optimized in the tetrapeptide fixed ligand Gly-Gly-Ala-Gly, as shown by data for 15 fixed ligands. The difference in the free energies of activation for the two competitive reactions is estimated to be approximately 7 kJ/mol for this particular fixed ligand. The sensitive nature of the methodology and the linear relationship between the logarithm of the fragment ion abundance ratio and the optical purity (intrinsic to the kinetic method) allows mixtures to be analyzed for as little as 1% enantiomeric excess (ee), by simply recording the ratios of fragment ion abundances in a tandem mass spectrum. These features are demonstrated in the case of the pharmacologically important 4-benzyl-2-oxazolidinones and in the case of penicillamine.

Anti-Bacterial Agents↗

Clustering of nucleosides in the presence of alkali metals: Biologically relevant quartets of guanosine, deoxyguanosine and uridine observed by ESI-MS/MS.

Electrospray ionization (ESI) mass spectra of nucleosides, recorded in the presence of alkali metals, display alkali metal ion-bound quartets and other clusters that may have implications for understanding non-covalent interactions in DNA and RNA. The tetramers of guanosine and deoxyguanosine and also their metaclusters (clusters of clusters), cationized by alkali metals, were observed as unusually abundant magic number clusters. The observation of these species in the gas phase parallels previous condensed-phase studies, which show that guanine derivatives can form quartets and metaclusters of quartets in solution in the presence of metal cations. This parallel behavior and also internal evidence suggest that bonding in the guanosine tetramers involves the bases rather than the sugar units. The nucleobases thymine and uracil are known to form magic number pentameric adducts with K+, Cs+ and NH4+ in the gas phase. In sharp contrast, we now show that the nucleosides uridine and deoxythymidine do not form the pentameric clusters characteristic of the corresponding bases. More subtle effects of the sugars are evident in the fact that adenosine and cytidine form numerous higher order clusters with alkali metals, whereas deoxyadenosine and deoxycytidine show no clustering. It is suggested that hydrogen bonding between the bases in the tetramers of dG and rG are the dominant interactions in the clusters, hence changing the ribose group to deoxyribose (and vice versa) generally has little effect. However, the additional hydroxyl group of RNA nucleosides enhances the non-selective formation of higher-order aggregates for adenosine and cytidine and results in the lack of highly stable magic number clusters. Some clusters are the result of aggregation in the course of ionization (ESI) whereas others appear to be intrinsic to the solution being examined.

Deoxyguanosine↗

A model for energy transfer in inelastic molecular collisions applicable at steady state or non-steady state and for an arbitrary distribution of collision energies.

A new model for energy exchange between translational and internal degrees of freedom in atom-molecule collisions has been developed. It is suitable for both steady state conditions (e.g., a large number of collisions with thermal kinetic energies) and non-steady state conditions with an arbitrary distribution of collision energies (e.g., single high-energy collisions). In particular, it does not require that the collision energies be characterized by a quasi-thermal distribution, but nevertheless it is capable of producing a Boltzmann distribution of internal energies with the correct internal temperature under quasi-thermal conditions. The energy exchange is described by a transfer probability density that depends on the initial relative kinetic energy, the internal energy of the molecule, and the amount of energy transferred. The probability density for collisions that lead to excitation is assumed to decrease exponentially with the amount of transferred energy. The probability density for de-excitation is obtained from microscopic reversibility. The model has been implemented in the ion trap simulation program ITSIM and coupled with an Rice-Rampsberger-Kassel-Marcus (RRKM) algorithm to describe the unimolecular dissociation of populations of ions. Monte Carlo simulations of collisional energy transfer are presented. The model is validated for non-steady state conditions and for steady state conditions, and the effect of the kinetic energy dependence of the collision cross-section on internal temperature is discussed. Applications of the model to the problem of chemical mass shifts in RF ion trap mass spectrometry are shown.

Journal Article↗

Recognition and quantification of binary and ternary mixtures of isomeric peptides by the kinetic method: metal ion and ligand effects on the dissociation of metal-bound complexes.

The kinetic method is applied to differentiate and quantify mixtures of isomeric tripeptides based on the competitive dissociations of divalent metal ion-bound clusters in an ion trap mass spectrometer. This methodology is extended further to determine compositions of ternary mixtures of the isomers Gly-Gly-Ala (GGA), Ala-Gly-Gly (AGG), and Gly-Ala-Gly (GAG). This procedure also allows to perform chiral quantification of a ternary mixture of optical isomers. The divalent metal ion Ca(II) is particularly appropriate for isomeric distinction and quantification of the isobaric tripeptides Gly-Gly-Leu/Gly-Gly-Ile (GGL/GGI). Among the first-row transition metal ions, Cu(II) yields remarkably effective isomeric differentiation for both the isobaric tripeptides, GGI/GGL using GAG as the reference ligand, and the positional isomers GAG/GGA using GGI as the reference ligand. This is probably due to agostic bonding: alpha-agostic bonding occurs between Cu(II) and GAG and beta-agostic bonding between Cu(II) and GGI, each produces large but different steric effects on the stability of the Cu(II)-bound dimeric clusters. These data form the basis for possible future quantitative analyses of mixtures of larger peptides such as are generated, for example, in combinatorial synthesis of peptides and peptide mimics.

Calcium↗

Ketalization of phosphonium ions by 1,4-dioxane: selective detection of the chemical warfare agent simulant DMMP in mixtures using ion/molecule reactions.

Phosphonium ions CH(3)P(O)OCH(3)(+) (93 Th) and CH(3)OP(O)OCH(3)(+) (109 Th) react with 1,4-dioxane to form unique cyclic ketalization products, 1,3,2-dioxaphospholanium ions. By contrast, a variety of other types of ions having multiple bonds, including the acylium ions CH(3)CO(+) (43 Th), CH(3)OCO(+) (59 Th), (CH(3))(2)NCO(+) (72 Th), and PhCO(+) (105 Th), the iminium ion H(2)C[double bond]NHC(2)H(5)(+) (58 Th) and the carbosulfonium ion H(2)C[double bond]SC(2)H(5)(+) (75 Th) do not react with 1,4-dioxane under the same conditions. The characteristic ketalization reaction can also be observed when CH(3)P(OH)(OCH(3))(2)(+), viz. protonated dimethyl methylphosphonate (DMMP), collides with 1,4-dioxane, as a result of fragmentation to yield the reactive phosphonium ion CH(3)P(O)OCH(3)(+) (93 Th). This novel ion/molecule reaction is highly selective to phosphonium ions and can be applied to identify DMMP selectively in the presence of ketone, ester, and amide compounds using a neutral gain MS/MS scan. This method of DMMP analysis can be applied to aqueous solutions using electrospray ionization; it shows a detection limit in the low ppb range and a linear response over the range 10 to 500 ppb.

Chemical Warfare Agents↗

Membrane introduction mass spectrometry for monitoring complexation equilibria of beta-cyclodextrin with substituted benzenes.

Membrane introduction mass spectrometry (MIMS) was used to monitor complexation reactions between beta-cyclodextrin (CD) and a series of benzene derivatives in aqueous solution. The equilibrium constants for benzene, chlorobenzene, bromobenzene, iodobenzene, toluene, cyanobenzene and nitrobenzene were determined. The suitability of MIMS for monitoring complexation reactions of organic compounds with host molecules was demonstrated. Structure-activity relationship analysis shows that the inclusion phenomena are driven by a variety of chemical forces, of which hydrophobicity is predominant for non-polar compounds, but not the only factor for more polar ones.

Journal Article↗

Ion/molecule reactions performed in a miniature cylindrical ion trap mass spectrometer.

A recently constructed miniature mass spectrometer, based on a cylindrical ion trap (CIT) mass analyzer, is used to perform ion/molecule reactions in order to improve selectivity for in situ analysis of explosives and chemical warfare agent simulants. Six different reactions are explored, including several of the Eberlin reaction type (M. N. Eberlin and R. G. Cooks, Org. Mass Spectrom., 1993, 28, 679-687) as well as novel gas-phase Meerwein reactions. The reactions include (1) Eberlin transacetalization of the benzoyl, 2,2-dimethyloximinium, and 2,2-dimethylthiooximinium cations with 2,2-dimethyl-1,3-dioxolane to form 2-phenyl-1,3-dioxolanylium cations, 2,2-dimethylamine-1,3-dioxolanylium cations and the 2,2-dimethylamin-1,3-oxathiolanylium cations, respectively; (2) Eberlin reaction of the phosphonium ion CH3P(O)OCH3+, formed from the chemical warfare agent simulant dimethyl methylphosphonate (DMMP), with 1,4-dioxane to yield the 1,3,2-dioxaphospholanium ion, a new characteristic reaction for phosphate ester detection; (3) the novel Meerwein reaction of the ion CH3P(O)OCH3+ with propylene sulfide forming 1,3,2-oxathionylphospholanium ion; (4) the Meerwein reaction of the benzoyl cation with propylene oxide and propylene sulfide to form 4-methyl-2-phenyl-1,3-dioxolane and its thio analog, respectively; (5) ketalization of the benzoyl cation with ethylene glycol to form the 2-phenyl-1,3-dioxolanylium cation; (6) addition/NO2 elimination involving benzonitrile radical cation in reaction with nitrobenzene to form an arylated nitrile, a diagnostic reaction for explosives detection and (7) simple methanol addition to the C7H7+ ion, formed by NO2 loss from the molecular ion of p-nitrotoluene to form an intact adduct. Evidence is provided that these reactions occur to give the products described and their potential analytical utility is discussed.

Chemical Warfare Agents↗

Solid phase micro-extraction in a miniature ion trap mass spectrometer.

Fiber introduction mass spectrometry (FIMS), a variation of solid-phase microextraction (SPME) and membrane introduction mass spectrometry (MIMS), is employed with a miniature mass spectrometer. The inlet system, constructed of commercially available vacuum parts, allows the direct introduction of the SPME needle vacuum chamber into the mass spectrometer. Thermal desorption of the analyte from the poly(dimethylsiloxane) (PDMS) coated fiber was achieved with a built in nichrome heater, followed by electron ionization of the analytes internal to the cylindrical ion trap (CIT). The system has been tested with several volatile organic compounds (VOC) in air and to analyze the headspace over aqueous solutions, with limits of detection in the low ppb range. The signal rise (10-90%) and fall (90-10%) times for the system ranged from 0.1 to 1 s (rise) and 1.2 to 6 s (fall) using heated desorption. In addition, this method has been applied to quantitation of toluene in benzene, toluene, xylene (BTX) mixtures in water and gasoline. This simple and rapid analysis method, coupled to a portable mass spectrometer, has been shown to provide a robust, simple, rapid, reproducible, accurate and sensitive (low ppb range) fieldable approach to the effective in situ analysis of VOC in various matrices.

Ions↗

Translational to vibrational energy conversion during surface-induced dissociation of n-butylbenzene molecular ions colliding at self-assembled monolayer surfaces.

Translational to vibrational (T-->V) energy conversion in the course of inelastic collisions of n-butylbenzene molecular ions with thiolate self-assembled monolayer (SAM) gold surfaces is studied to better understand internal energy uptake by the hyperthermal projectile ions. The projectile ion is selected by a mass spectrometer of BE configuration and product ions are analyzed using a quadrupole mass analyzer after kinetic energy selection with an electric sector. The branching ratio for formation of the fragment ions m/z 91 and m/z 92, measured over a range of collision energies, is used to estimate the average internal energy with the aid of calculations based on unimolecular dissociation kinetics [Rice-Ramsperger-Kassel-Marcus (RRKM) theory]. The measured T-->V conversion efficiencies (the fraction of the laboratory kinetic energy converted into internal energy) are 11 approximately 12% for dodecanethiolate SAM (H-SAM) and 19 approximately 20% for 2-perfluorooctylethanethiolate SAM (F-SAM), respectively, over ranges of a few 10s of eV. The values are similar to those reported earlier for other thermometer molecules undergoing surface collisions. Chemical sputtering leading to ionization of the surface is a prominent feature of the surface-induced dissociation (SID) spectra of n-butylbenzene acquired using the H-SAM surface but not the F-SAM surface because of the lower ionization energy of the former.

Journal Article↗

Miniature cylindrical ion trap mass spectrometer.

A miniature cylindrical ion trap mass spectrometer is described, and preliminary data are presented. Functionality and performance of laboratory-scale instruments have been maintained to the extent possible in this battery-operated mass spectrometer. Capabilities include tandem mass spectrometry experiments. Custom-designed electronic components include the RF scanning and amplification system, data acquisition components, and lens power supplies, as well as a custom-software application. Direct leak and membrane introduction inlet systems are used for sample introduction. A mass/charge range of approximately 250 Th with unit mass resolution has been demonstrated.

Journal Article↗

Analytical performance of a miniature cylindrical ion trap mass spectrometer.

The analytical performance of a fieldable cylindrical ion trap (CIT)-based miniature mass spectrometer is described. A detailed description of the instrument itself is to be found in the immediately preceding paper (Patterson, G. E.; Guymon, A. J.; Riter, L S.; Everly, M.; Griep-Raming, J.; Laughlin, B. C.; Ouyang, Z.; Cooks, R. G., Miniature Cylindrical Ion Trap Mass Spectrometer, Anal. Chem. 2002, 24, 6145-6153). Applications employing the MS/MS and MSn capabilities of the miniature instrument and analytical performance criteria are given here. The limit of detection for methyl salicylate, introduced as the pure vapor, is estimated as 1 pg. The resolution, R = m/delta m, where delta m, measured as full width at half-maximum, is estimated as 100. Monitoring of organic compounds in air is performed using a permeation membrane introduction device coupled to the mass spectrometer. Water monitoring is performed using an external membrane introduction mass spectrometry (MIMS) system, with acetophenone and toluene serving as model compounds. Data are given for chemical warfare agent simulants, methyl salicylate, and dimethyl methyl phosphonate (DMMP) in air. On-line detection of menthol vapor emitted from a cough drop is reported. Methyl salicylate in air gives a recognizable mass spectrum at 400 ppb in the ambient system, while use of a heated membrane brings the detection limit down to 10 ppb.

Journal Article↗

Quotient ratio method for quantitative enantiomeric determination by mass spectrometry.

The quotient ratio (QR) method, a new quantitative method for enantiomeric determination by mass spectrometry, is presented. The method is illustrated by the case in which a chiral analyte (A) and a chiral reference compound (ref*) are simultaneously coordinated to a transition metal ion (e.g., Cu2+ or Zn2 ) to form a singly charged deprotonated cluster ion in the course of electrospray ionization. The trimeric complex ion (three chiral ligands-2 mol of the analyte and 1 mol of the reference compound) is collisionally activated and undergoes dissociation by competitive loss of either a neutral reference or a neutral analyte. The ratio of the product ion branching ratios measured when pure chiral reference compounds (ref*D and ref*L) are employed in separate experiments is related via the kinetic method to the enantiomeric composition of the chiral mixture. This quotient ratio is logarithmically related to enantiomeric purity. In contrast to the previous single ratio method (Tao, W. A.; Zhang, D.; Wang, F.; Thomas, P. D.; Cooks, R. G. Anal. Chem. 1999, 71, 4427), the QR method reported here requires only one sample of the analyte with known optical purity to allow construction of a calibration curve. Accurate determinations of enantiomeric excess for amino acids and the chiral drug DOPA are demonstrated.

Amino Acids↗

Surface modification and patterning using low-energy ion beams: Si-O bond formation at the vacuum/adsorbate interface.

Modification of hydroxyl-terminated self-assembled monolayer (HO-SAM) surfaces by collision of low-energy (15 eV) hyperthermal Si(CH3)3+ ions is shown to lead to Si-O bond formation and terminal trimethylsilyl ether formation. Modification was verified by in situ mass spectrometry using chemical sputtering with CF3+ ions (70 eV), ex situ secondary ion mass spectrometric analysis (12 kV Ga+ primary ion beam), and through X-ray photoelectron spectroscopy by monitoring Si (2s). The nature of the surface modification was further established by analysis of synthetic SAM surfaces made up of mixtures of the trimethylsilyl-11-mercapto-1-undecane ether and various proportions of the hydroxyl-terminated mercaptan (11-mercapto-1-undecanol). These mixed surfaces, as well as the spectroscopic data, indicate that ca. 30% of the hydroxyl chains are covalently modified at saturation coverage. Analogous surface transformations are achieved using Si(CH3)2F+ and Si(CH3)2C6H5+.

Journal Article↗

Silylation of an OH-terminated self-assembled monolayer surface through low-energy collisions of ions: a novel route to synthesis and patterning of surfaces.

Using a multi-sector ion-surface scattering mass spectrometer, reagent ions of the general form SiR(3) (+) were mass and energy selected and then made to collide with a hydroxy-terminated self-assembled monolayer (HO-SAM) surface at energies of approximately 15 eV. These ion-surface interactions result in covalent transformation of the terminal hydroxy groups at the surface into the corresponding silyl ethers due to Si--O bond formation. The modified surface was characterized in situ by chemical sputtering, a low-energy ion-surface scattering experiment. These data indicate that the ion-surface reactions have high yields (i.e. surface reactants converted to products). Surface reactions with Si(OCH(3))(3) (+), followed by chemical sputtering using CF(3) (+), yielded the reagent ion, Si(OCH(3))(3) (+), and several of its fragments. Other sputtered ions, namely SiH(OCH(3))(2)OH(2) (+) and SiH(2)(OCH(3))OH(2) (+), contain the newly formed Si--O bond and provide direct evidence for the covalent modification reaction. Chemical sputtering of modified surfaces, performed using CF(3) (+), was evaluated over a range of collision energies. The results showed that the energy transferred to the sputtered ions, as measured by their extent of fragmentation in the scattered ion mass spectra, was essentially independent of the collision energy of the projectile, thus pointing to the occurrence of reactive sputtering.A set of silyl cations, including SiBr(3) (+), Si(C(2)H(3))(3) (+) and Si(CH(3))(2)F(+), were similarly used to modify the HO-SAM surface at low collision energies. A reaction mechanism consisting of direct electrophilic attack by the cationic projectiles is supported by evidence of increased reactivity for these reagent ions with increases in the calculated positive charge at the electron-deficient silicon atom of each of these cations. In a sequential set of reactions, 12 eV deuterated trimethylsilyl cations, Si(CD(3))(3) (+), were used first as the reagent ions to modify covalently a HO-SAM surface. Subsequently, 70 eV SiCl(3) (+) ions were used to modify the surface further. In addition to yielding sputtered ions of the modified surface, SiCl(3) (+) reacted with both modified and unmodified groups on the surface, giving rise not only to such scattered product ions as SiCl(2)OH(+) and SiCl(2)H(+), but also to SiCl(2)CD(3) (+) and SiCl(2)D(+). This result demonstrates that selective, multi-step reactions can be performed at a surface through low-energy ionic collisions. Such processes are potentially useful for the construction of novel surfaces from a monolayer substrate and for chemical patterning of surfaces with functional groups.