PubMed Health⌕ Search

Biomedical subjects

R J Korst

Publications and source records attributed to R J Korst.

20 records · Page 2Linked to original sources

Validation of respiratory mechanics software in microprocessor-controlled ventilators.

BACKGROUND AND METHODS: Several microprocessor-controlled ventilators, available for clinical use, contain optional computer software programs capable of performing near-instantaneous determinations of airway resistance and lung compliance. This study was undertaken to determine the validity of the measurements for airway resistance and lung compliance obtained by the software packages on three microprocessor-controlled ventilators. Three ventilator models were studied. An artificial ventilator-patient circuit was constructed using a test lung and an endotracheal tube. Airway pressure and gas flow curves were recorded using conventional means. Static lung compliance and airway resistance were calculated using standard equations, while automated measurements were obtained from the ventilators. The following parameters were then varied to simulate a wide variety of clinical situations: tidal volume, peak inspiratory flow rate, respiratory rate, endotracheal tube, and test lung compliance. RESULTS: Automated measurements were highly correlated with values obtained manually (resistance: Puritan-Bennett 7200a r2 = .94, Bear 5 r2 = .98, Veolar r2 = .96; compliance: 7200a r2 = .93, Bear 5 r2 = .97, Veolar r2 = .97). Calculated limits of agreement between the two methods demonstrate that although not in absolute agreement, the software-determined values for airway resistance and lung compliance differed from the manually derived values in a ventilator-specific, predictable fashion. CONCLUSIONS: The correlation and agreement demonstrated between values of airway resistance and lung compliance measured by the respiratory mechanics software packages and those values derived manually suggest that these software packages may be useful for measuring trends, as well as responding to treatment in the clinical setting. These results apply only to the controlled, mechanical ventilation mode. Further studies are indicated to validate this software in patients capable of generating spontaneous breaths.

Airway Resistance↗

Factors associated with outcome in blunt aortic injury: a population-based study.

A population-based study was conducted for two contiguous states representing a population of 9.1 million to determine whether age, injury severity score, major complications, and preexisting conditions contribute to the outcome of patients diagnosed with blunt traumatic aortic injury. A secondary analysis reviewed patients with blunt aortic injury admitted over a six-year period to a trauma center located in one of the states to examine other more detailed factors related to mortality. Age was the only variable that correlated statistically with mortality in both populations analyzed. (Region P = .004; trauma center P = .0012) The severity of injury showed a tendency for decreased survival with increasing injury severity score. The elderly (age > or = 55) in both data sets sustained higher mortality from blunt aortic injury. In the trauma center population, the elderly had more delay in diagnosis than the younger patient population.

Adult↗