Quantitative polarized light microscopy.

We describe a simple modification to a confocal microscope, which analyses the state of polarization of light emerging from the specimen so as to permit quantitative polarized light microscopy to be performed. The system uses a novel form of rotating analyser which, together with lock-in detection, permits images to be obtained where the image contrast corresponds to both specimen retardance and orientation (e.g. in the case of a birefringent specimen). Images are presented from a wide range of specimens and the origin of the contrast observed from simple point scatterers is investigated both theoretically and experimentally.

Journal Article↗

New imaging modes for lenslet-array tandem scanning microscopes.

The tandem scanning microscope permits confocal images to be obtained in real time and viewed directly by eye. The light budget of these instruments may be increased from a few percent to a few tens of percent by incorporating an array of microlenses so as to increase the amount of illumination light that reaches the specimen. These instruments are configured for fluorescence imaging together with laser illumination. We describe how the versatility of the instrument may be enhanced to permit the use of incoherent light sources as well as extending the imaging modes to include bright-field reflection.

Dentin↗

Video-rate confocal endoscopy.

Rigid endoscopes provide high quality optical images of reasonably accessible regions of the inner body, especially regions such as the aero-digestive and genital tracts. In order to enhance the versatility of these instruments we describe a development that permits confocal endoscopic images to be obtained - along with traditional endoscopic images - in real-time, from within the living patient. The system is based around a host lenslet-array tandem scanning microscope, which is capable of producing images viewed directly by eye. These types of confocal microscope are configured for fluorescence imaging together with laser illumination. Hard and soft tissues in the mouth were imaged using this combined system.

Endoscopy↗

Time-domain whole-field fluorescence lifetime imaging with optical sectioning.

A whole-field time-domain fluorescence lifetime imaging (FLIM) microscope with the capability to perform optical sectioning is described. The excitation source is a mode-locked Ti:Sapphire laser that is regeneratively amplified and frequency doubled to 415 nm. Time-gated fluorescence intensity images at increasing delays after excitation are acquired using a gated microchannel plate image intensifier combined with an intensified CCD camera. By fitting a single or multiple exponential decay to each pixel in the field of view of the time-gated images, 2-D FLIM maps are obtained for each component of the fluorescence lifetime. This FLIM instrument was demonstrated to exhibit a temporal discrimination of better than 10 ps. It has been applied to chemically specific imaging, quantitative imaging of concentration ratios of mixed fluorophores and quantitative imaging of perturbations to fluorophore environment. Initially, standard fluorescent dyes were studied and then this FLIM microscope was applied to the imaging of biological tissue, successfully contrasting different tissues and different states of tissue using autofluorescence. To demonstrate the potential for real-world applications, the FLIM microscope has been configured using potentially compact, portable and low cost all-solid-state diode-pumped laser technology. Whole-field FLIM with optical sectioning (3D FLIM) has been realized using a structured illumination technique.

Animals↗

Wide-field optically sectioning fluorescence microscopy with laser illumination.

We describe an extremely simple method by which optically sectioned fluorescence images may be obtained with conventional microscopes using laser illumination. A one-dimensional grid pattern is introduced into the illumination system, together with a rotating ground glass diffuser. This causes an image of the grid pattern to be projected into the specimen. Images taken at three spatial positions of the grid are processed in a simple manner to provide optically sectioned images of fluorescent specimens.

Animals↗

A wavefront generator for complex pupil function synthesis and point spread function engineering.

We describe a simple method to produce an arbitrary complex optical field using a ferroelectric liquid crystal spatial light modulator. The system is configured so as to act as a pupil plane filter in a confocal microscope. The ability to tune the complex pupil function permits the system to be used both to modify the imaging performance by effectively engineering the point spread function as well as to remove optical aberrations present in the optical system.

Journal Article↗

Adaptive aberration correction in a two-photon microscope

We demonstrate aberration correction in two-photon microscopy. Specimen-induced aberrations were measured with a modal wavefront sensor, implemented using a ferro-electric liquid crystal spatial light modulator (FLCSLM). Wavefront correction was performed using the same FLCSLM. Axial scanned (xz) images of fluorescently labelled polystyrene beads using an oil immersion lens show restored sectioning ability at a depth of 28 &mgr;m in an aqueous specimen.

Journal Article↗

A method for characterizing longitudinal chromatic aberration of microscope objectives using a confocal optical system

We describe a novel method of characterizing the longitudinal chromatic aberration of microscope objectives by recording a series of axial responses as a function of wavelength as a plane reflector is scanned through the focal region of a confocal microscope. Measurements are presented for a variety of objectives with differing degrees of correction. The use of the chromatic focal shift to measure surface profiles is also discussed.

Journal Article↗

Real-time three-dimensional imaging of macroscopic structures.

We describe an extremely simple method of obtaining optically sectioned images with conventional low-power imaging systems in real time. A single spatial frequency grid pattern is projected onto an object. Images taken at three spatial positions of the grid projection are processed to provide 3D images of macroscopic structures.

Journal Article↗

Efficient real-time confocal microscopy with white light sources.

The main advantage of confocal microscopes over their conventional counterparts arises from their ability to optically 'section' nearly transparent materials; the thin image slices thus obtained can be used to reconstruct three-dimensional images, a capability which is particularly useful for the study of biological specimens. Confocal microscopes have previously used either a single laser-illuminated point-source and single point-detector (which are scanned in tandem across the object) or white-light illumination with multiple point-sources and detectors. Single-point-source systems, however, do not usually form images in real time and are restricted to using available laser wavelengths. Multiple-point-source systems, on the other hand, produce images in real time but use light very inefficiently--typically 1% or less is used for imaging. Here we demonstrate a white-light, multiple-point-source method which can in principle produce images in real time with light efficiencies as high as 50%. This system is likely to find broad practical application, particularly in the imaging of weakly reflecting or weakly fluorescent specimens.

Animals↗

Confocal endoscopy via structured illumination.

We describe a simple modification to a rigid endoscope so as to provide both high-quality conventional and confocal images of reasonably accessible regions of the body. This versatile system uses a structured illumination approach together with a conventional incoherent illumination source. Images taken in fluorescence are presented using this combined conventional and confocal endoscope.