PubMed HealthSearch

Biomedical subjects

R K Babayan

Publications and source records attributed to R K Babayan.

At least 19 recordsLinked to original sources

Secure transmission of urologic images and records over the Internet.

PURPOSE: Telemedicine has become a common method for the transmission of images and patient data across long distances. Our goal was to assess the efficiency and accuracy of Photomailer MD software, a store-and-forward telemedicine system, in the urologic setting. METHODS: Photomailer MD software was loaded on two computers in the host institution, one with a T1 connection to the Internet and the other with a dial-up modem connection (24,000 bits/second), and computers at three remote sites. A total of 14 clinical cases, comprised of digitized histories and radiographic images, were sent to the remote institutions four separate times using the four transmission modes available: nonencrypted, 56-bit encryption, 128-bit encryption, and 128-bit encryption with password. The following data points were recorded: file size before and after encryption, file transmission times, and diagnostic accuracy of the remote urologists. One-way ANOVA was used to compare mean values statistically, while the z-test was used to compare diagnostic accuracies. RESULTS: Encryption increased the file size by a mean of 37.8%, with the three encryption modes increasing file sizes by the same number of kilobytes. When a dial-up modem was used, encrypted files required a significantly longer transmission time (P < 0.05) than the unencrypted files. The same trend was seen with the T1 connection, although the differences often were not significant. When T1 transmission times were compared with modem times with other variables held constant, modem times were significantly longer (P < 0.05). Diagnostic accuracies for each of the three remote centers ranged from 85.7% to 100%. Differences in accuracy rates between attending physicians and residents were not significant. CONCLUSIONS: Photomailer MD provides a secure, convenient, and affordable method of transmitting patient images and records via the Internet. Transmission speed was significantly greater when using a T1 line and also tended to be faster when files were not encrypted. There was no significant difference in transmission time among the three encryption modes; therefore, 128-bit encryption with a password should be used to maximize security. Diagnostic accuracies were comparable to those in the literature. In general, 640 x 480-pixel resolution was adequate for urologic diagnoses, although higher-resolution images may improve accuracy.

Analysis of Variance

Advances in digital imaging during endoscopic surgery.

BACKGROUND AND OBJECTIVE: Digital imaging capabilities have recently been incorporated into a number of video systems. Contrast enhancement when using a rigid or semirigid endoscope improves image definition by seeking out existing transitions in detail. Only the areas of transition are accentuated, whereas areas without detail are unaffected. During flexible endoscopy, fiberoptic bundles create a classic honeycomb appearance. The use of "fiberscope" filters minimizes this appearance by expanding the image of each fiberoptic fiber. We therefore assessed whether new developments in digital video image processing have improved image quality for endoscopic surgery. MATERIALS AND METHODS: Fifty urologists reviewed a video playback of various endourologic procedures. The type of endoscope was identified, but the urologic surgeon was blinded to the level of enhancement (high or low) or fiberscope filter (A or B) used. Each video clip was scored from 1 to 5 for the following image variables: identification of structure, detail of image, and background noise or interference. All results were averaged and compared using Student's paired t-test. RESULTS: During rigid endoscopy, the high and low digital enhancement settings were both superior to no enhancement (P < 0.001), and high enhancement was better than low (P < 0.001). With semirigid endoscopic procedures, high and low digital enhancement were comparable but were superior to no enhancement (P < 0.001). Filters A and B were no better than no enhancement. There was a significant improvement noted with the use of filter A or B during flexible ureteroscopy over no enhancement (P < 0.001). In addition, filter A was better than filter B (P < 0.001). CONCLUSIONS: Digital enhancement settings during video endoscopy significantly improve images from rigid and semirigid endoscopes. The digital fiberscope filter significantly improves images obtained during flexible ureteroscopy. Digital image enhancement capabilities should be strongly considered when upgrading video systems. Digital technology must be further studied to improve clinical video imaging during endoscopic surgery.

Endoscopy

Surgeon's workshop: a simple method of antegrade collagen placement for postprostatectomy incontinence.

We describe a modified method for antegrade placement of periurethral collagen in incontinent men. In this technique, a flexible cystoscope is used to guide the placement of a specially designed needle into the bladder neck and external sphincter region via an antegrade transvesical approach. The 19-gauge, 28-cm long needle is passed suprapubically without a sheath. The procedure may be performed with local anesthesia and intravenous sedation only and takes less than 30 minutes.

Collagen

Secured medical imaging over the Internet.

The Internet has established itself as an affordable, extremely viable and ubiquitous communications network that can be easily accessed from virtually any point in the world. This makes it ideally suited for medical image communications. Issues regarding security and confidentiality of information on the Internet, however, need to be addressed for both occasional, individual users and consistent enterprise-wide users. In addition, the limited bandwidth of most Internet connections must be factored into the development of a realistic usermodel and resulting protocol. Open architecture issues must also be considered so that images can be communicated to recipients who do not have similar programs. Further, application-specific software is required to integrate image acquisition, encryption and transmission into a single, streamlined process. Using Photomailer software provided by PhysiTel Inc., the authors investigated the use of sending secured still images over the Internet. The scope of their investigation covered the use of the Internet for communicating images for consultation, referral, mentoring and education. Photomailer software was used at several local and remote sites. The program was used for both sending and receiving images. It was also used for sending images to recipients who did not have Photomailer, but instead relied on conventional email programs. The results of the investigation demonstrated that using products such as Photomailer, images could be quickly and easily communicated from one location to another via the Internet. In addition, the investigators were able to retrieve images off of their existing email accounts, thereby providing greater flexibility and convenience than other systems which require scheduled transmission of information on dedicated systems. We conclude that Photomailer and similar products may provide a significant benefit and improve communications among colleagues, providing an inexpensive means of sending secured images on the Internet.

Computer Communication Networks

Thin-section helical computed tomography of the bladder: initial clinical experience with virtual reality imaging.

OBJECTIVES: To evaluate the application of virtual reality imaging of the bladder (virtual cystoscopy) in the detection of bladder masses. METHODS: Six patients (mean age 61 years, range 43 to 75) with hematuria and positive findings on conventional cystoscopy were studied by means of thin-section helical computed tomography of the air-distended bladder. Using volume-rendering algorithms, interactive intraluminal views of the bladder mucosa were generated (virtual cystoscopy). Results of virtual cystoscopy were compared with those of conventional cystoscopy in each case. RESULTS: Twenty-six (100%) of 26 masses (mean size 1.7 cm, range 0.3 to 6), detected on conventional cystoscopy, were visualized on virtual cystoscopy. Twelve of 26 masses measured less than 1 cm in maximum diameter. All masses were pathologically proven transitional cell carcinomas. Virtual cystoscopy was well tolerated by all patients, and no complications occurred. CONCLUSIONS: Our results indicate that virtual cystoscopy is an accurate technique for detection of intrinsic bladder masses. It may represent a radiologic adjunct to conventional cystoscopy for initial evaluation of patients with hematuria and for surveillance of patients after bladder tumor resection.

Adult

A multicenter clinical trial investigating the use of a fluoroscopically controlled cutting balloon catheter for the management of ureteral and ureteropelvic junction obstruction.

PURPOSE: We assessed the efficacy of a fluoroscopically controlled cutting balloon catheter for the treatment of ureteropelvic junction and ureteral strictures. MATERIALS AND METHODS: A multicenter trial was performed that included 66 endopyelotomies and 49 endoureterotomies. To our knowledge this study represents the largest number of patients with ureteropelvic junction obstruction and ureteral strictures tested with this device to date. RESULTS: With a mean followup of 7.8 months (range 1 to 17.9) the patency rate was 77% for endopyelotomy, with 72% of the primary and 100% of the secondary ureteropelvic junction obstructions remaining patent. The endoureterotomy patients were followed for an average of 8.7 months (range 1.2 to 17.0), with a patency rate of 55%. CONCLUSIONS: A cutting balloon endoscopic incision is effective in the majority of cases, with patency rates for endopyelotomies and endoureterotomies that mirror current endourological reports using other, albeit more time intensive and more invasive, incisional techniques.

Adolescent

A porcine model for renal hemodynamic study during laparoscopy.

Laser Doppler flowmetry (LDF) is a sensitive method for the measurement of microvascular blood flow in tissue. The method has been found useful for estimating skin, liver, or gastrointestinal blood flow. Whether it can be applied laparoscopically and whether it is able to measure the intraparenchymal blood flow of an intraabdominal organ is still unknown. In a pilot study, 6 pigs received a laparotomy for placement of a 19-gauge LDF needle probe into the renal parenchyma. Three different locations of the lower pole kidney were chosen for the blood flow measurement. The reliability of using the instrument to measure the renal tissue blood flow was assessed by comparison of the results of renal arterial blood flow obtained from a well-established methodology--ultrasonic Doppler flowmetry. Recordings were taken following (a) intravenous administration of 0.005 mg/kg norepinephrine, (b) manual compression of the suprarenal aorta, and (c) intravenous injection of a lethal dose of phenobarbital (50 mg/kg). Measurements of LDF were possible in all kidney units. The renal tissue perfusion detected by LDF correlated excellently with the renal arterial blood flow under different renal perfusion pressures. The feasibility of using LDF probe to measure the renal tissue perfusion in a laparoscopic model was then assessed in 15 pigs. Under pneumoperitoneum, the right kidneys were approached transperitoneally with the animal in the decubitus position. A total of three trocars were used. The peritoneum and Gerota's fascia were incised and the LDF needle probe was manipulated and inserted by an endoforceps into the renal tissue via a 5-mm trocar. The insertion of the LDF needle probe was technically feasible in all 15 kidney units, and the depth of insertion could be adjusted under direct vision. Baseline values for the renal cortical and renal medullary blood flow were 50.1 +/- 17.7 and 8.8 +/- 3.3 ml/min/100 g tissue, respectively. Spatial variations of the LDF measurements averaged 6%, and temporal variations over 15 min averaged 5%. Four additional hemodynamic parameters were simultaneously recorded, including left carotid artery blood flow, aortic blood pressure, inferior vena caval pressure, and intraabdominal pressure. It appears that systemic and renal hemodynamic parameters can be monitored reliably and continuously in the porcine model. This method allows further information concerning hemodynamic changes and safety of laparoscopy to be obtained.

Animals

Changes in urinary output and electrolytes during gaseous and gasless laparoscopy.

Urological laparoscopy has gained increasing acceptance recently. Alterations in renal water and electrolyte homeostasis by carbon dioxide peritoneal insufflation, retroperitoneal insufflation and abdominal wall lifting were measured in 30 well-hydrated pigs over a 2-h period. Oliguria was observed after gaseous insufflation but not alter lifting the abdominal wall. Return to normal urinary output was observed at 30 min after release of pneumoretroperitoneum, and 60 min after pneumoperitoneum. Creatinine clearance declined, while the clearance rates of potassium, sodium and urea remained unchanged during peritoneal and retroperitoneal insufflation. An elevated serum aldosterone concentration was found which may mediate the increased urinary excretion of potassium and decreased urinary excretion of sodium found during peritoneal insufflation. Renal function remained stable, despite an elevation of serum creatine kinase being elicited after lifting the abdominal wall. In conclusion, significant changes in water and electrolyte homeostasis occurred gaseous, not gasless, laparoscopy in pigs.

Animals

Renal arterioureteral hemorrhage: a complication of acucise endopyelotomy.

The Acucise ureteral catheter is a ureteral cutting balloon device that recently received approval for retrograde endopyelotomy. We report a case of a postoperative lower pole renal arterioureteral hemorrhage after retrograde endopyelotomy requiring interventional radiographic treatment. Significant gross hematuria after Acucise endopyelotomy may indicate a communication between the vasculature and collecting system. Prompt arteriography with embolization should be considered in this clinical situation.

Adult

Implications of prostate micrometastases in pelvic lymph nodes: an archival tissue study.

OBJECTIVES: In the United States, radical retropubic prostatectomy for adenocarcinoma usually includes a staging pelvic lymphadenectomy. If frozen section analysis of the lymph nodes fails to reveal any evidence of metastases, the prostate is removed. We have previously noted that as many as 56% of patients undergoing radical prostatectomy demonstrate rising serum prostate-specific antigen (PSA) levels by 4 years postoperatively. This report was designed to determine whether micrometastases undetectable by conventional pathologic methods: could have accounted for these biochemical failures. METHODS: A retrospective analysis of formalin-fixed paraffin-embedded pelvic lymph node material was undertaken using a reverse transcription-polymerase chain reaction (RT-PCR)-based assay designed to amplify messenger RNA from PSA. All specimens were obtained from a group of 57 patients with prostate cancer who had undergone staging pelvic lymphadenectomy at the time of radical prostatectomy, and whose long-term follow-up was known. RESULTS: Although all of these nodes appeared to be free of tumor by conventional pathologic methods, a RT-PCR assay was used to identify evidence of prostate metastases in 44% of evaluable samples. Of these, 14 of 16 went on to manifest rising serum PSA values by 5 years postoperatively. CONCLUSIONS: These results suggest that molecular staging of pelvic lymph nodes prior to planned therapy for clinically organ-confined prostate cancer may better distinguish between patients with local disease and those for whom local therapy alone will not be curative. To our knowledge, this is the first large-scale retrospective gene expression study published.

Adenocarcinoma

Complications of extraperitoneal balloon dilation.

The success of balloon dissection techniques has given laparoscopic surgeons the option of a direct extraperitoneal approach to urologic disease. Unfortunately, these techniques are not without risks. We report on four cases of complications secondary to balloon dilation. In two instances, balloon misplacement caused dissection between muscle layers. This resulted in conversion to an open procedure in one instance and to a postoperative flank hernia in another. Balloon rupture with loose fragments occurred in two patients. In one of these cases, the peritoneum was lacerated, with balloon fragments displaced within the peritoneal cavity.

Adult

A rapid and simple method for the detection of prostate-specific antigen mRNA in archival tissue specimens using a reverse transcription-polymerase chain reaction assay.

OBJECTIVES: Polymerase chain reaction (PCR) amplification of DNA from archival, fixed tissue sources is now performed routinely. In this report, we describe a reproducible technique for mRNA amplification from archival tissues. METHODS: Archival, fixed tissue was treated with a modification of a rapid, acid guanidinium technique. The RNA yielded was reverse transcribed and subjected to 40 cycles of two-step PCR, using a panel of primers designed to encompass relatively short (less than 250 bp) cDNA fragments. PCR products were analyzed by agarose gel electrophoresis followed by ethidium bromide staining. RESULTS: Using fixed, paraffin-embedded specimens of human prostate, we have demonstrated a reproducible pattern of reverse transcription (RT)-PCR products using several different primer sets. Our data suggest that RNA degradation proceeds to fragments approximately 250 bp or shorter in length but that many of these fragments survive intact over extended periods of time and are of suitable quality to serve as a template for RT and subsequent PCR amplification. CONCLUSIONS: We describe a technique that will allow the retrospective analysis of archival tissues for gene expression. These methods are generally applicable to a wide variety of systems. Such a method will make it possible to perform retrospective studies of gene expression in the archival tissues of patients whose eventual clinical course is already known, greatly shortening the time needed for genetic outcome studies in slowly growing tumors, such as prostate cancer.

Base Sequence

Transurethral ultrasound-guided laser-induced prostatectomy (TULIP): past, present, and future.

The TULIP system was the first apparatus designed specifically for laser ablation of the prostate. Laser energy is delivered under ultrasound guidance with the probe moved distally from the bladder neck at the rate of 0.5 to 1 mm/sec. The aim is to produce a deep level of coagulation necrosis. Postoperatively, patients have a suprapubic catheter until they can void comfortably. As of 1994, 2-year results showed a 69% reduction in the mean Boyarsky symptom score (N = 57) v 63% at 6 months (N = 212) and a mean increase in the peak urine flow rate of 68% (N = 46) v 59% at 6 months (N = 195). At present, it is not clear whether TULIP will become commercially available in the United States.

Follow-Up Studies

The impact of pneumoperitoneum, pneumoretroperitoneum, and gasless laparoscopy on the systemic and renal hemodynamics.

BACKGROUND: The use of therapeutic laparoscopy has become widespread recently. It is important to assess the effects of gaseous and gasless laparoscopy on systemic and renal hemodynamics. STUDY DESIGN: A prospective controlled animal study was performed on 40 well-hydrated pigs. Systemic and renal hemodynamics were monitored during peritoneal insufflation, retroperitoneal insufflation, and abdominal wall lifting for a period of two hours. A laser Doppler flow meter was applied laparoscopically to measure the renal cortical tissue perfusion. RESULTS: Peritoneal insufflation of carbon dioxide to a pressure of 15 mm Hg elicited transient elevations of the aortic pressure and carotid arterial blood flow. Unilateral pneumoretroperitoneum caused a smaller change on systemic hemodynamics. Pneumoperitoneum and pneumoretroperitoneum caused oliguria. Superficial renal cortical blood flow reduction decreased by an average of 60 percent in the compressed kidney, and blood flow returned to the pre-insufflation level after the pressure was released. A gradual decrease of tissue perfusion in the contralateral kidney and a concomitant gradual increase of the intra-abdominal pressure were observed when pneumo-retroperitoneum was maintained for two hours. No significant changes in urinary output and in systemic and renal hemodynamics were found when the abdominal wall was lifted up with a force equivalent to 15 mm Hg. CONCLUSIONS: Significant systemic and renal hemodynamic changes were elicited in gaseous but not in gasless laparoscopy, which may explain the decreased urinary output observed during gaseous laparoscopy. Pneumoperitoneum caused greater systemic and renal hemodynamic alterations than pneumoretroperitoneum; however, the effects were transient and reversible after a period of two hours.

Animals

Radical prostatectomy for adenocarcinoma of the prostate: the influence of preoperative and pathologic findings on biochemical disease-free outcome.

OBJECTIVE: This retrospective study evaluated the outcome for a cohort of men undergoing radical retropubic prostatectomy alone as primary treatment for clinical T1-2 prostate adenocarcinoma. METHODS: Sixty-two patients treated at Boston University Medical Center between 1987 and 1992 underwent radical prostatectomy alone without adjuvant or neoadjuvant endocrine therapy. Actuarial and multivariate analyses were made of disease-free outcome according to preoperative tumor T stage, prostate-specific antigen (PSA), and biopsy grade, and according to the pathologic findings at surgery. Recurrence was defined as the persistence or recurrence of detectable serum PSA four or more weeks following surgery. RESULTS: Of all patients judged clinically to have localized disease (T1-2), 52 percent proved to have pathologic T3 tumors. Of these, 81 percent had positive surgical margins. The strongest preoperative predictors of pT3 disease were the biopsy Gleason grade and the initial serum PSA value. Actuarial analysis showed the overall likelihood of remaining free from detectable PSA at four years to be 43 percent (75% for those with organ-confined disease and 27% for those who were pT3). The poorest prognosis was seen in those with seminal vesicle involvement. Biopsy Gleason grade and initial PSA were independent preoperative predictors of biochemical failure in a Cox regression analysis but clinical T stage was not. CONCLUSIONS: The biopsy Gleason grade and initial PSA were identified as strong preoperative predictors of disease-free outcome. We confirmed the favorable prognosis of men with organ-confined disease, but emphasize the high likelihood of relapse in those with positive surgical margins or seminal vesicle invasion.

Adenocarcinoma