Advances in digital imaging during endoscopic surgery.

Abstract

BACKGROUND AND OBJECTIVE: Digital imaging capabilities have recently been incorporated into a number of video systems. Contrast enhancement when using a rigid or semirigid endoscope improves image definition by seeking out existing transitions in detail. Only the areas of transition are accentuated, whereas areas without detail are unaffected. During flexible endoscopy, fiberoptic bundles create a classic honeycomb appearance. The use of "fiberscope" filters minimizes this appearance by expanding the image of each fiberoptic fiber. We therefore assessed whether new developments in digital video image processing have improved image quality for endoscopic surgery. MATERIALS AND METHODS: Fifty urologists reviewed a video playback of various endourologic procedures. The type of endoscope was identified, but the urologic surgeon was blinded to the level of enhancement (high or low) or fiberscope filter (A or B) used. Each video clip was scored from 1 to 5 for the following image variables: identification of structure, detail of image, and background noise or interference. All results were averaged and compared using Student's paired t-test. RESULTS: During rigid endoscopy, the high and low digital enhancement settings were both superior to no enhancement (P < 0.001), and high enhancement was better than low (P < 0.001). With semirigid endoscopic procedures, high and low digital enhancement were comparable but were superior to no enhancement (P < 0.001). Filters A and B were no better than no enhancement. There was a significant improvement noted with the use of filter A or B during flexible ureteroscopy over no enhancement (P < 0.001). In addition, filter A was better than filter B (P < 0.001). CONCLUSIONS: Digital enhancement settings during video endoscopy significantly improve images from rigid and semirigid endoscopes. The digital fiberscope filter significantly improves images obtained during flexible ureteroscopy. Digital image enhancement capabilities should be strongly considered when upgrading video systems. Digital technology must be further studied to improve clinical video imaging during endoscopic surgery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Aslan, R L Kuo, K Hazel, R K Babayan, G M Preminger. 1999. Advances in digital imaging during endoscopic surgery.. https://doi.org/10.1089/end.1999.13.251. https://pubmed.health/record/pubmed%3A10405901/advances-in-digital-imaging-during-endoscopic-surgery

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Training with simulation improves residents' endovascular procedure skills.

BACKGROUND: Endovascular procedure simulators are now commercially available and in use for physician training. The purpose of this study was to evaluate the role of simulation-based training in vascular surgery residencies. METHODS: Residents from vascular surgery programs in a five-state area were invited to participate in a series of 2-day endovascular training programs that used a high-fidelity endovascular procedure simulator (SimSuite; Medical Simulation Corporation, Denver, Colo), didactic instruction, computer-based training, and tabletop procedure demonstrations. The curriculum covered arteriography and intervention for treatment of aortoiliac, renal, and carotid artery disease. Nine residents participated, with one to three per training session. Each completed an average of 9.5 simulated endovascular cases. Performance on a standardized TransAtlantic Inter-Society Consensus B iliac angioplasty/stenting case was used to assess endovascular skills and knowledge at the beginning of the training program, and this was repeated at the completion of the training. Performance metrics were measured by the simulator, faculty observed trainees' performance of simulated cases, and trainees provided their evaluations of the usefulness of the simulation experiences. RESULTS: Endovascular procedural skills on the standardized iliac intervention case improved after completion of the training program. Compared with performance early on day 1, performance improved (P < or = .05; paired t test): total procedure time decreased 54%, volume of contrast decreased 44%, and fluoroscopy time decreased 48% (mean change from baseline). Selection of angioplasty balloon catheters and stents was improved, and the average number of catheters used and stents deployed decreased, although this did not reach statistical significance. Faculty observation allowed identification of shortcomings of knowledge and skills, including common problems with selection of catheter, balloon, and stent sizes; correct positioning of the sheath; and intraprocedural monitoring. Postcourse evaluations indicated support for the use of simulation in vascular surgery residents' endovascular training. CONCLUSIONS: Training with a simulator, incorporated into an individual or small group learning session, offers a means to learn and realistically practice endovascular procedures without direct risk to patients, with measurable improvements in key performance metrics. How simulation training affects subsequent clinical performance has yet to be established.

Endoscopy↗

Intraoperative surgical navigation for endoscopic sinus surgery: rationale and indications.

PURPOSE OF REVIEW: The present review discusses the rationale and indications for image-guided surgery through a critical discussion of registration concepts as well as clinical reports. RECENT FINDINGS: The surgical navigation accuracy achieved by commercially available image-guided surgery systems is best reported as target registration error. Clinically achievable target registration error is probably in the 1.5-2.0 mm range. Dry lab studies of registration serve to highlight the principles of registration, the process through which image-guided surgery systems calculate the one-to-one mapping relationship between the preoperative imaging data and the intraoperative surgical volume. Reports on image-guided surgery have highlighted its usefulness in primary and revision endoscopic sinus surgery, osteoplastic frontal sinusotomy, transsphenoidal hypophysectomy, endoscopic cerebrospinal fluid leak repair and endoscopic pterygomaxillary fossa biopsy. Both three-dimensional computed tomography angiography and computed tomography-magnetic resonance fusion images have been incorporated into IGS for advanced minimally invasive endoscopic skull base procedures. The American Academy of Otolaryngology-Head and Neck Surgery policy statement accurately summarizes the current consensus for image-guided surgery applications. SUMMARY: Image-guided surgery has emerged as an important technology, which both general otolaryngologists and subspecialty rhinologists can employ for a wide variety of procedures.

Endoscopy↗