PubMed HealthSearch

Biomedical subjects

R L Lamb

Publications and source records attributed to R L Lamb.

11 recordsLinked to original sources

Obtaining reliable measurements of knee extensor torque produced during maximal voluntary contractions: an experimental investigation.

The purpose of this study was to develop and test a protocol that could be used to obtain reliable measurements of knee extensor torque produced during maximal voluntary contractions. On each of 3 days, 10 subjects performed six consecutive maximal voluntary contractions, in the same randomized order, for each of the following 10 conditions: concentric isokinetic contractions at velocities of 30 degrees, 90 degrees, 120 degrees, and 180 degrees/s; eccentric isokinetic contractions at velocities of 30 degrees, 90 degrees, 120 degrees, and 180 degrees/s; and isometric contractions at 40 and 60 degrees of knee flexion. The peak torques produced were examined to determine on which day and during which contraction subjects produced the greatest torques for each condition. This information was used to develop a practice protocol. Fifteen different subjects were tested following this protocol. Subjects participated in two practice sessions, a test session, and a retest session. Intraclass correlation coefficients (ICCs) were calculated to determine the degree of agreement between torques for the test and retest sessions. The ICCs ranged from .87 to .98. The protocol developed appears to be useful for obtaining reliable measurements of knee extensor torque.

Acceleration

Intertester reliability of judgments of the presence of trigger points in patients with low back pain.

The purpose of this study was to determine the intertester reliability of assessments of the presence of trigger points in the region of the lumbar spine of patients with low back pain (LBP). A total of six trigger points described by Travell and Simons were studied. The trigger point examination procedures described by Travell and Simons were used by 12 physical therapists. Randomly paired therapists examined 50 patients for 197 trigger points. The Kappa coefficient, percent agreement, the observed proportion of positive agreement (Ppos), and the observed proportion of negative agreement (Pneg) were used to describe reliability. Kappa values ranged from .29 to .38. Percent agreement ranged from 76% to 79%. Ppos ranged from .43 to .52. The low Kappa and Ppos values suggest different therapists are unable to reliably determine when a trigger point is present in a patient with LBP. This study suggests the usefulness of examining for the presence of trigger points in patients with LBP should be questioned.

Adult

Estate planning: some first steps.

After you've worked a lifetime to build an estate, it's possible for the federal government to snatch up to 55 percent of it away from your heirs, and this could happen even if you've made a will. Clearly, an estate not carefully and professionally planned is one destined for lawyers' pockets, the courts, and both federal and state taxes.

Financial Management

Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting.

The purpose of this study was to examine the intratester and intertester reliability for goniometric measurements of knee flexion and extension passive range of motion (PROM). In addition, parallel-forms reliability for PROM measurements of the knee obtained by use of a goniometer and by visual estimation was examined. The intertester reliability for visual estimates of the PROM of the knee was also examined. Repeated measurements were obtained on 43 patients in a clinical setting. The intraclass correlation coefficients (ICCs) for intratester reliability of measurements obtained with a goniometer were .99 for flexion and .98 for extension. Intertester reliability for measurements obtained with a goniometer was .90 for flexion and .86 for extension. The ICCs for parallel-forms reliability for measurements obtained with a goniometer and by visual estimation ranged from .82 to .94. The intertester reliability for measurements obtained by visual estimation was .83 for flexion and .82 for extension. Results suggest clinicians should use a goniometer to take repeated PROM measurements of a patient's knee to minimize the error associated with these measurements.

Adult

Exercise-induced muscle soreness after concentric and eccentric isokinetic contractions.

The purpose of this two-part study was to determine whether the amount of exercise-induced muscle soreness differs between subjects who perform concentric and eccentric isokinetic contractions of their quadriceps femoris muscles. In experiment 1, subjects were randomly assigned to either an eccentric or a concentric exercise group and both groups exercised at the same power level. In experiment 2, subjects were randomly assigned to either an eccentric or a concentric exercise group and both groups exercised with maximal effort. Muscle soreness ratings, obtained by using a visual analogue scale, were taken immediately before exercise and at 24 and 48 hours postexercise. Changes in muscle soreness ratings between exercise groups from preexercise to postexercise periods were compared in both experiments, using a one-way between-subjects analysis of variance. There was no difference in the change in muscle soreness from preexercise to post-exercise periods between groups exercising at equal power levels. Subjects who exercised using eccentric contractions with maximal effort demonstrated greater increases in muscle soreness than those who performed concentric contractions. The results suggest that exercise intensity, rather than contraction type, may be the dependent factor in producing exercise-induced muscle soreness.

Adult

Effects of therapeutic ultrasound on bone marrow in dogs.

With a thermocouple in the medullary cavity of one dog's femur, the increases in bone marrow temperature were demonstrated at five different intensities of ultrasound. The right distal femurs of six dogs were treated ten times, three dogs at 1.5 w/cm2 and three dogs at 2.5 w/cm2 each for five minutes. At a later date, two of these dogs received an additional ten minutes of ultrasound at 2.5 w/cm2 for ten treatments. Histological and hematological studies gave presumptive evidence of bone marrow damage and regeneration. A marked increase in oil was also seen in the bone marrow smears.

Blood Cell Count