PubMed Health⌕ Search

Biomedical subjects

R M Haralick

Publications and source records attributed to R M Haralick.

5 recordsLinked to original sources

A knowledge-based boundary delineation system for contrast ventriculograms.

Automated left-ventricle (LV) boundary delineation from contrast ventriculograms has been studied for decades. Unfortunately, no accurate methods have ever been reported. A new knowledge based multistage method to automatically delineate the LV boundary at end diastole (ED) and end systole (ES) is discussed in this paper. It has a mean absolute boundary error or about 2 mm and an associated ejection fraction error of about 6%. The method makes extensive use of knowledge about LV shape and movement. The processing includes a multiimage pixel region classification, shape regression, and rejection classification. The method was trained and cross-validated tested on a database of 375 studies whose ED and ES boundary had been manually traced as the ground truth. The cross-validated results presented in this paper show that the accuracy is close to and slightly above the interobserver variability.

Artificial Intelligence↗

A general technique for automatic left ventricle boundary validation: relation between gray scale cardioangiograms and observed boundary errors.

This article presents an automatic left ventricle boundary validation technique using the gray scale cardioangiograms, the observed boundary errors, and the left ventricle boundaries from any source that needs to be validated. This validation technique is based on the gray scale information near the boundary of the left ventricle in the cardioangiograms. Using a mutually exclusive window of fixed size, which is centered on the left ventricle boundary vertex and along the left ventricle contour, we compute a difference in contrast value for areas of the window both inside and outside the left ventricle region. These contrast values then are regressed against the observed boundary errors. The observed boundary errors are computed using the polyline distance measure, by comparing two sets of boundaries: boundaries estimated from any boundary estimation algorithm, and the original ground truth boundaries as traced by the cardiologist. We performed our experiments on a database of 245 patient studies, each having two frames: end-diastole (ED) and end-systole (ES). The mean boundary error before running the validation system was 4.4 mm. Using our boundary validation system, by rejecting 5% to 10% of the patient studies, the validation system results in an error of 4.0 mm for the cross-validation case and 3.85 mm for the ideal case. We show the reliability curves of our validation system by computing the probability of false alarm, probability of mis-detection, and mean predicted errors when a total of n patients are rejected from the database of 245 studies.

Algorithms↗

Two-view motion analysis: a unified algorithm.

We present a linear algorithm for determining the three-dimensional rotation and translation of a rigid object from two time-sequential perspective views using point correspondences. The algorithm is different from existing ones in two respects. First, various measures for combating noise are incorporated. Second, the algorithm is unified in the sense that, assuming that the surface assumption holds, it can handle both the case of nonzero translation and the case of zero translation.

Algorithms↗

Three-dimensional ultrastructure of the Golgi apparatus in bovine mammary epithelial cells during lactation.

The three-dimensional ultrastructure of the Golgi apparatus in milk secreting epithelial cells of bovine mammary gland was explored. From computer-aided reconstructions of serial thin sections, it was determined that the Golgi apparatus was composed of a single set of stacked cisternae. The three-dimensional shape of the dictyosome varied from cell to cell, but the overall shape was that of a hollow cone, cylinder, or bowl. The cis and trans surfaces of the dictyosome were arranged in three-dimensional space such that the cis face was located on the outer surface of the hollow structure and the trans face on the inner surface. The cytoplasmic channel (secretory channel) that traversed the longitudinal axis of the hollow dictyosome contained secretory vesicles. Densely stacked cisternae of rough endoplasmic reticulum surrounded the dictyosome, and microvesicles appeared to fuse with, or bud from, cisternae of both organelles. These findings suggest that Golgi apparatus of the lactating epithelial cell is highly organized and that the Golgi apparatus and secretory channel are essentially an independent compartment within the cell.

Animals↗