PubMed Health⌕ Search

Biomedical subjects

R M Lust

Publications and source records attributed to R M Lust.

At least 37 records · Page 2Linked to original sources

Multicenter trial of automated nitroprusside infusion for postoperative hypertension. Titrator Multicenter Study Group.

Hypertension is common after a cardiac operation and may result in postoperative hemorrhagic and other complications. Most often this problem has been treated using manually controlled doses of intravenous sodium nitroprusside. To evaluate the clinical impact of an automated closed-loop administration system on patients after cardiotomy, a prospective trial was conducted at nine clinical centers. Patients with hypertension were managed by either manual nitroprusside titration (n = 532) or a closed-loop automated titration system (n = 557). Patient groups were not significantly different in age, weight, or height. Moreover, the types of surgical procedures were comparable: primary coronary artery bypass grafting, 59.2% and 58.9%, manual group versus automated group; repeat coronary artery bypass grafting, 10.5% and 8.6%, respectively; valve procedures, 11.3% and 15.1%, respectively; and other cardiac procedures, 19.0% and 17.4%, respectively (all p = not significant). The automated group showed a significant reduction in the number of hypertensive episodes per patient (1.8 +/- 0.2 versus 0.6 +/- 0.07; p = 0.0001. At the same time, the number of hypotensive episodes per patient was reduced with automated closed-loop titration (0.40 +/- 0.05 versus 0.30 +/- 0.03; p = 0.02). Chest tube drainage (866 +/- 37 mL versus 693 +/- 23 mL [mean +/- standard error of the mean]; p = 0.0001), percentage of patients receiving transfusion (40.0% versus 33.0%; p = 0.02), and total amount transfused (2.4 +/- 0.12 units versus 2.0 +/- 0.10 units; p = 0.0003) were all reduced significantly by the use of an automated titration system.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Transfusion↗

Competitive flow from a fully patent coronary artery does not limit acute mammary graft flow.

The shriveled, stenotic mammary graft sometimes observed after internal mammary artery (IMA) to coronary artery bypass grafting has been attributed to competitive flow from the insufficiently stenosed native coronary vessel. To study further the effects of native coronary artery competing flow on IMA graft flow, 10 dogs (mean weight, 23.5 +/- 3.69 kg) underwent coronary artery bypass grafting using the pedicled left IMA anastomosed to a normal, fully patent proximal circumflex (CFX) coronary artery. The procedure was performed through a left thoracotomy, off pump, using a brief local occlusion to perform the anastomosis. Native in situ IMA flow, CFX flow distal to the anastomosis, and IMA graft flow were measured using calibrated electromagnetic flow probes. When the CFX proximal to the anastomosis was occluded transiently, IMA flow increased to supply 100% of the previously measured distal CFX flow (60.2 +/- 7.9 mL/min). When both the IMA graft and CFX proximal to the anastomosis were patent, total distal perfusion was maintained (58.9 +/- 7.8 mL/min) and relative IMA graft flow (26.5 +/- 3.3 mL/min) was proportional to the relative diameter of the IMA graft to the native coronary artery (r = 0.96). The mean flow in the IMA in situ on the chest wall before its division was 23.8 +/- 8.1 mL/min. These results suggest that, at least acutely in a canine model, IMA graft flow is maintained above in situ levels even when grafted to a completely patent coronary artery and that acute competitive flow probably does not cause mammary artery shriveling.

Animals↗

Surgical management of renal cell carcinoma with extensive intracaval involvement using a venous bypass system suitable for rapid conversion to total cardiopulmonary bypass.

Renal cell carcinoma involves the vena cava in approximately 4% of the patients. Presently surgical extirpation is the only form of therapy that can result in cure. Recently management of extensive vena caval involvement has involved the use of cardiopulmonary bypass with circulatory arrest and hypothermia. We describe a technique using a venous bypass pump system (femoral vein to right atrium) for resection of renal cell carcinoma with suprahepatic vena caval extension (type II), which avoids the risks and complications of cardiac arrest and hypothermia but allows for rapid conversion to total cardiopulmonary bypass should the intraoperative need arise.

Aged↗

Feasibility of intraoperative aortic root angiography in the identification of critical coronary lesions.

Early revascularization is critical for the treatment of acute myocardial infarction (AMI) because the ischemic myocardium begins to suffer irreversible damage after 4 h from the onset of symptoms. However, to make a diagnosis, perform coronary angiography, and prepare for operative revascularization usually takes longer than 4 h. Also, once a patient develops severe cardiogenic shock, coronary angiography is often impossible. Without angiography, the patient is no longer a candidate for surgical repair. To circumvent this problem, we designed this experiment to determine whether intraoperative aortic root angiography after cardiopulmonary bypass and cardioplegic arrest could satisfactorily substitute for angiographic examination in the identification of critical coronary lesions. The feasibility of this approach was tested in dog hearts in which one or tow of the major coronary arteries were ligated. The ascending aorta was then clamped, contrast material was injected, and continuous real-time fluoroscopic images were obtained and recorded on videotape. The videotape was then analyzed by three physicians independently, each without prior knowledge of the lesion locations. Lesions of the left anterior descending artery, the circumflex coronary artery, and the right coronary artery were identified with 94, 91, and 94% accuracy, respectively, for an overall identification rate of 92%. We conclude that aortic root angiography reliably demonstrates coronary artery lesions, and refinements in this technique may allow certain patients to undergo coronary operations without preoperative catheterization.

Angiocardiography↗

Internal mammary artery use. Sternal revascularization and experimental infection patterns.

We have described previously the acute sternal devascularization produced by mobilization of one or both internal mammary arteries (IMAs). The present experiments were conducted to examine the time course of sternal revascularization and infection patterns after IMA use. Twenty-four 8-week-old domestic pigs were obtained from a herd in which active Streptococcus faecalis had been detected in recent litters. After control blood flow procedures (microspheres) were completed, each pig underwent a median sternotomy; one or both IMAs were mobilized as a pedicle, and the sternotomy was repaired. Repeat blood flow determinations were made in half the pigs at 1 week and in the remainder after 2 weeks. The pigs were killed, the wound was examined, cultures were taken as indicated, and tissue was harvested for blood flow analysis. Despite the retention of an intact IMA on the contralateral side, persistent, significant sternal ischemia existed 2 weeks after repair. However, when both IMAs were used, the extent of devascularization was exaggerated, and revascularization was impaired further. Revascularization of intercostal muscle occurred more rapidly and was essentially returned to normal 2 weeks after sternotomy and IMA harvest. Active mediastinitis with erosion of the sternum was found in one (17%) of six pigs at 1 week and in four (67%) of six pigs at 2 weeks when the IMAs had been rotated bilaterally. No wound infections were detected in the single IMA resection group. These data suggest that bilateral IMA mobilization may delay an already slow revascularization process and predispose to infectious complications.

Animals↗

Transfemoral balloon aortic occlusion during open cardiopulmonary resuscitation improves myocardial and cerebral blood flow.

These experiments were designed to determine whether the limited cardiac output during open cardiac massage could be preferentially directed to the coronary and cerebral vessels by balloon occlusion of the descending thoracic aorta. Sixteen dogs were instrumented to monitor cardiac output and left atrial, right atrial, right ventricular, left ventricular, and arterial blood pressures. Measurements of myocardial and cerebral blood flow distribution during massage were made using the radioactive microsphere technique. Each animal underwent two episodes of fibrillation and resuscitation. In one episode the arrest was managed by open massage alone, and in the other, open massage was accompanied by balloon occlusion, with the order randomized. When compared to control, open cardiac massage was associated with a significant decrease in mean arterial pressure; however, the addition of balloon occlusion produced a 130% increase in the mean arterial pressure that was obtained during open CPR (control, 93 +/- 5 mm Hg; massage alone, 35 +/- 2 mm Hg; massage + balloon, 76 +/- 2 mm Hg, P less than 0.01). In a similar fashion, although the absolute blood flow was reduced by 50% when compared to control, the blood flow (ml/min/g) to the brain and heart during massage was 100% better when balloon occlusion was employed (brain: control, 0.41 +/- 0.03; massage only, 0.05 +/- 0.01; massage + balloon, 0.25 +/- 0.02, P less than 0.01; heart: control, 1.46 +/- 0.11; massage alone, 0.35 +/- 0.05; massage + balloon, 0.71 +/- 0.05, P less than 0.01). These results suggest that aortic occlusion significantly increased myocardial and cerebral perfusion patterns during ventricular fibrillation and open cardiac massage.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Donor-specific tolerance permits burn allografting without increased sepsis.

Early excision and allografting of massive burns is beneficial. However, chronic immunosuppression, utilized to prolong allograft survival, increases the potential risk of infection. We have previously shown long-term skin allograft survival in mice with a 30% total body surface area (TBSA) burn by inducing donor-specific tolerance (DST) using only perigrafting administration of antithymocyte globulin (ATG) and donor bone marrow (DBM). Chronic immunosuppression is avoided. This study tests whether induction of DST compromises host resistance to infection. Resistance to a septic challenge created by cecal ligation and puncture (CLP) 10 days after a 30% TBSA burn was investigated in the following groups of mice: [table: see text] Positive blood cultures were documented for 97% of mortalities. Burn excision and grafting significantly (P less than or equal to 0.05) decreased mortality. No increased mortality was seen in allografted mice receiving ATG or ATG and DBM compared to isografted mice receiving no immunosuppression. These studies suggest that skin allografting with DST may permit the benefits of burn excision without the risks of infection seen with chronic immunosuppression.

Animals↗

Reappraisal of the mechanism for cerebrospinal fluid hypertension during aortic surgery.

Cerebrospinal fluid (CSF) hypertension during aortic surgery is a poorly understood, multifactorial event that may increase the risk of spinal cord injury. To assess the factors that may contribute to changes in CSF pressure during aortic surgery, measurements of ascending arterial and CSF pressures were made in 17 anesthetized mongrel dogs. Changes in CSF patterns were monitored under several conditions tested in random sequence. These included systemic hypertension produced by an infusion of phenylephrine, cross-clamping of the descending thoracic aorta, and manual, superior displacement of the transverse aortic arch (arch elevation), either alone or in conjunction with the cross-clamp. Hypertension, cross-clamping, and cross-clamping combined with arch elevation all produced significant increases in ascending mean arterial pressure (204 +/- 20, 170 +/- 8, and 158 +/- 11 mm Hg, respectively, vs. 117 +/- 8 mm Hg [control]; (p less than 0.01). Small, nonsignificant increases in CSF pressure were detected in the cross-clamp group, but none were detected with hypertension alone, despite significant increases in ascending arterial blood pressure in both groups. Thus, neither arterial hypertension nor cross-clamping alone could be demonstrated directly to cause significant CSF hypertension. However, when aortic elevation (displacement) was combined with cross-clamping, the rise in CSF pressure increased to significant levels, even though the ascending arterial hypertension was least severe in this group. In contrast, arch elevation alone did not produce any significant increase in ascending arterial pressure but did produce an approximately 114% increase in CSF pressure (15.2 +/- mm Hg vs. 7.7 +/- 1 mm Hg [control]; p less than 0.01.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Improvement in thoracic aortic pressure after proximal aortic cross-clamping by balloon occlusion of the distal aorta.

Spinal cord hypoperfusion injury is a devastating complication of cross-clamping the proximal thoracic aorta. The collateral circulation around the cross-clamp is generally poorly developed, and the run-off is immense, resulting in extremely low thoracic aortic and spinal cord perfusion pressures. The authors postulated that balloon occlusion of the abdominal aorta might confine this reduced collateral flow around the cross-clamp to the thoracic aorta. In 8 of 16 dogs subjected to aortic cross-clamping of the aorta just beyond the arch vessels, the abdominal aorta was also occluded by a balloon. Thoracic aortic pressure and spinal cord perfusion pressure were significantly higher in the animals with aortic balloon occlusion than in those without balloon occlusion (77 +/- 8 mm Hg versus 26 +/- 1 mm Hg, p less than 0.01, and 67 +/- 8 mm Hg versus 18 +/- 2 mm Hg, p less than 0.01, at 10 minutes after cross-clamping). Abdominal aortic balloon occlusion increases thoracic aortic pressure after the aorta is cross-clamped proximally. Further studies are necessary in primates to assess the effect of this procedure in spinal cord perfusion and the rate of paraplegia.

Animals↗

Improved protection of chronically inflow-limited myocardium with retrograde coronary sinus cardioplegia.

The effects of retrograde coronary sinus cardioplegia (CSC) and conventional aortic route cardioplegia (ARC) on reperfusion blood flow patterns were compared in 18 mongrel dogs having ameroid-induced coronary collaterals. Animals were placed on cardiopulmonary bypass and cooled systemically. The aorta was clamped, and the hearts were arrested with a bolus infusion of hypothermic (4 degrees C) hyperkalemic cardioplegic solution delivered either into the aortic root or through a balloon catheter placed in the coronary sinus. After 45 minutes of ischemic arrest, hearts were reperfused, and blood flow patterns were measured at 1, 5, 10, and 60 minutes. In the normal region, a significant hyperemia occurred with both CSC and ARC. However, the peak reactive transmural flow was 120% more with ARC than with CSC (4.55 +/- 0.45 vs. 2.12 +/- 0.19 ml/min/g, respectively; p less than 0.05) and remained elevated after 60 minutes of reperfusion, when CSC flows had returned to control levels. In the collateral-dependent region, a significant hyperemia was observed with ARC that persisted throughout reperfusion. However, with CSC, no significant changes in blood flow were detected at any time during reperfusion. Thus, the decreased hyperemic response after arrest suggests a reduced energetic debt with CSC compared with ARC and may indicate superior myocardial protection with CSC. This is particularly evident in chronically inflow-restricted myocardial regions.

Animals↗

Postextrasystolic potentiation: analysis of methods of induction.

Studies were conducted in 15 patients with coronary artery disease to determine if the type of pacing used to induce an extrasystole had a bearing on subsequent postextrasystolic potentiation (PESP) and if the fact that these were evaluated in jeopardized or nonjeopardized portions of the ventricle altered the ability to assess PESP. Two types of pacing were used. In the first group, all beats in the test sequence (basic heart rate, extrasystole, and postextrasystole) were delivered from a programmed external pacemaker. This group was termed the "all-paced" (AP) group, and the postextrasystole was introduced before a compensatory pause could occur, so that loading conditions within the ventricle at the last regular beat and after the extrasystole were not different. In the second group, the extrasystole was coupled to the sensed intrinsic heart rate of the patient, and the postextrasystole was allowed to occur spontaneously. This group was termed the "sensed-paced" (SP) group. Despite differences in basic heart rates and postextrasystolic intervals between the two groups, comparable results were obtained with the two techniques. However, the postextrasystole in the SP group occurred much earlier than expected, probably due to intrinsic cardioacceleration during ventriculography. The net result was that loading conditions in this group before and after the extrasystole were also not different from each other. Results from the pacing techniques were not influenced by whether they were obtained from jeopardized or nonjeopardized segments.(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiac Catheterization↗

Postextrasystolic potentiation: regional wall motion before and after revascularization.

We evaluated the augmentation of contractility which follows an extrasystole (postextrasystolic potentiation: PESP) in patients before and after coronary revascularization surgery for angina pectoris. PESP was induced by methods which result in essentially identical loading conditions of the ventricle for the beat before the extrasystole and the beat after the extrasystole. We evaluated regional ventricular function before and after revascularization in "jeopardized" segments (supplied by a coronary vessel with significant coronary disease) and "nonjeopardized" segments (supplied by a vessel without significant disease). All coronary lesions were proximal to all three anterior or all posterior segments. Those jeopardized segments with patent grafts which had augmented with PESP improved their baseline function following revascularization. Conversely, those jeopardized segments which failed to augment with PESP decreased their basic function following revascularization. Those segments in which the grafts were occluded failed to augment with PESP after attempted revascularization. Perioperative myocardial infarction resulted in a drop in ejection fraction and a failure to augment with PESP. The nonjeopardized segments responded to PESP similarly to the ischemic augmenting segments. The results of this study suggest that PESP does detect ventricular segments which will improve basic function following revascularization. Those segments which fail to augment with PESP are most likely more ischemic than the augmenting segments, will not improve, and may even decrease function following revascularization.

Angina Pectoris↗

Use of a programmable calculator for rapid, low-cost processing of echocardiographic records.

A comparative study was performed to determine the accuracy of a programmable calculator with supplemental digitizer in echocardiographic analysis. Twenty separate measurements were collected per heart beat from five different dogs, taking five heart beats from each dog. The measurements were made by an echocardiographic technician (ET), echocomputer (EC), and by a programmable calculator (HP). In a triple comparison (ET-HP, ET-EC, HP-EC) there were no significant differences in the values obtained, suggesting that the programmable calculator can provide a highly accurate and rapid means of processing echocardiographic measurements, thereby providing the advantages of the echocomputer without the cost of such a device.

Animals↗

Applicability of echocardiography in volume determinations in experimental animals.

A method is described for the use of echocardiography in volume determinations in the experimental animal. Suitability of the technique in both acute and chronically implanted animals was tested. Stroke volumes derived from calculations based on echo data were compared with those obtained by an electromagnetic flow probe placed around the aorta. High correlation was found in both the acute (r = 0.96, P less than 0.001) and the chronic (r = 0.89, P less than 0.001) preparations. Cardiac output computed from echocardiographic data and compared with those based on either flow probe or indicator-dilution techniques also showed a high degree of correlation in both the acute (r = 0.91 and 0.95, respectively; P less than 0.001) and chronic (r = 0.98 and 0.94, respectively, P less than 0.001) preparations. It is suggested that echocardiography, because of the potential to measure many indicators of myocardial function in addition to volume, represents a significant improvement in the techniques available for basic cardiovascular experimentation.

Animals↗

Cardiac taurine levels during endotoxemia.

Three hours after dogs were given an intravenous injection of Escherichia coli endotoxin significant decreases in cardiac taurine levels were observed in the apex and epicardial regions of the right ventricle and in all regions sampled from the left ventricle. A decrease in taurine was seen in all regions of the heart (including the atria) by 90 min after endotoxin treatment but the results were not statistically significant. Echocardiography and left ventricular cannulation were used in a separate group to confirm that the dose of endotoxin used was adequate to produce depression of cardiac output and force of contraction.

Animals↗

Postextrasystolic potentiation and contractile reserve: requirements and restrictions.

These studies were conducted to examine the basic characteristics of postextrasystolic potentiation (PESP) and the relationship of loading effects to PESP. Measurements of left ventricular (LV) and aortic pressures, the rate of pressure rise, and echocardiographically determined LV dimensions were made in anesthetized open-chest dogs. The hearts were paced, and timed extrasystoles were introduced that were followed by postextrasystoles (PES). PES's were elicited after an interval equal to either a full compensatory pause or a time when the diastolic properties of the LV could not be distinguished from control (isolength). Potentiation of contraction for the PES's introduced after an isolength pause was dependent on both the heart rate and the extrasystolic interval, whereas the PES's that occurred after a full pause showed no dependence on either of these intervals. PESP elicited during the isolength period was not dependent on either preload and afterload. It is concluded that PESP depends on the combination of heart rate and extrasystolic and postextrasystolic intervals. Further, PESP may be inaccurate in assessing contractile reserve unless the heart rate and extrasystolic interval are known and the PES is introduced after an isolength pause.

Animals↗

A carotid stenosis model in canines.

A carotid stenosis model was developed in canines in order to study the effects of systemic blood pressure and hemodilution on cerebrovascular perfusion and metabolism during cardiopulmonary bypass in the setting of significant coexistent inflow stenosis. Under general anesthesia, through a low midline neck incision, the carotid sheath was entered and the carotid artery was isolated and retracted medially. The vertebral artery could be identified posterolaterally. After ligating the vertebral artery with a 00 silk tie, carotid stenosis was created by tying bilateral carotid arteries over an 18-gauge needle using a 00 silk tie. The needle was then removed, leaving a tight stenosis. To determine the degree of stenosis, arteriograms were performed, revealing high-grade lesions of greater than 90% stenosis in the carotid arteries and absence of flow through the vertebral arteries. Cerebral blood flow studies during cardiopulmonary bypass (CPB) were performed, revealing a significant decline. Carotid arteries were harvested at the conclusion of the experiments, revealing tight lesions on direct inspection. The mean gradient measured across stenotic segments was >25 mm Hg. In conclusion, a carotid stenosis model can be created successfully in dogs by ligating the vertebral arteries bilaterally and simply using the shaft of a needle to standardize the lumen size of the carotid arteries. We found the diameter of an 18-gauge needle sufficient to produce stenoses of greater than 90% as evidenced by arteriograms.

Animals↗