Improved preservation of early reperfusion patterns in severe left ventricular hypertrophy using retrograde coronary sinus cardioplegia.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R M Lust.
Explore the source record for details and available documents.
The flow reactivity of an internal thoracic artery (ITA) graft and a vein graft for multiple coronary beds in response to different modes of cardiac pacing remains unclear. These experiments were conducted in 14 anesthetized dogs with the ITA or the vein grafted to the circumflex coronary artery, off pump, using a brief local occlusion. The left main coronary artery was occluded, rendering the entire left ventricle totally dependent upon the ITA graft or the vein graft. When the left main coronary artery was occluded and the heart rate was 120 beats per min, graft flow was 93.4 +/- 9.6 ml per min in the ITA, and 96.1 +/- 10.4 ml per min in the vein graft. Atrial pacing to increase heart rates 25% to 150 beats per min increased both the ITA graft flow (110.3 +/- 9.7 ml per min, p < 0.05 versus flow in sinus rhythm) and the vein graft flow (109.8 +/- 7.9 ml per min, p < 0.05 versus flow in sinus rhythm). The increases in flow in both cases were not attributable to changes in perfusion pressure. In contrast, ventricular pacing to the same heart rate decreased systemic pressure slightly, but insignificantly. Despite the slight decrease in perfusion pressure, ventricular pacing increased ITA flow (107.9 +/- 8.4 ml per min, p < 0.05 versus flow in sinus rhythm), but the increase in vein graft flow was not significant compared with flow in sinus rhythm (102.1 +/- 7.3 ml per min, p = ns versus flow in sinus rhythm).(ABSTRACT TRUNCATED AT 250 WORDS)
Leukocyte mediated pulmonary injury may delay recovery after cardiac surgery, and leukocyte depletion during bypass has been suggested. Two groups of patients were randomly, prospectively assigned from 50 sequential patients to undergo open heart surgery using cardiopulmonary bypass, either with (n = 25) or without (n = 25) leukocyte filters. The two groups were not significantly different regarding age, gender, race, pre-operative ejection fraction, pump time, or cross-clamp time. Post operative arterial blood gases (pO2: 173 +/- 66 vs 192 +/- 107; pCO2: 30.2 +/- 8.2 vs 30.8 +/- 8.0), pulmonary vascular resistance (PVR 105 +/- 45 vs 112 +/- 50 dyne cm-5), time on ventilator (17.8 +/- 6.4 vs 19.7 +/- 8.6 hr), and length of hospital stay (7.65 +/- 4.57 vs 8.52 +/- 5.87 days) were not different between groups (mean +/- SD, with vs without filters, respectively). Arterial oxygenation was somewhat poorer, and PVR was somewhat lower in the leukocyte filtered group. However, these trends did not produce significant decreases in total ventilator time or length of hospital stay. In-line filtration did remove leukocytes, but did not reduce circulating leukocyte count. In effect, leukocyte filtration produced an effective leukocyte concentration at the filter site. These data do not support routine incorporation of in-line leukocyte filtration during bypass.
Intimal hyperplasia (IH) limits the long-term success of veins as arterial grafts. IH occurs in veins partly as an adaptive process to arterial pressure conditions. The authors have previously reported early success with cryopreserved (CP) saphenous veins as aortocoronary bypass grafts, and they have hypothesized that CP arterial segments were already structurally adapted for arterial conditions. Six femoral arterial segments were harvested from three adult donor dogs, and cryopreserved. The segments were thawed and implanted into six recipient dogs, in end-to-end fashion, as interpositional grafts in the femoral artery. A similar length of native femoral artery was removed from the implant site and grafted in the contralateral femoral artery of the same animal to serve as native autograft-matched controls. Grafts were harvested bilaterally after 2 (n = 3) and 4 weeks (n = 3), perfusion fixed (80 mmHg, 15 min), and analyzed histologically. All grafts were patent at harvest, and flows distal to the grafted segments were not significantly different between grafts within an animal either at implant or subsequent harvest. Although CP arterial grafts still showed slight but significant dilation compared with native autograft, the dilation was much less than seen previously with either CP or native venous segments. No evidence of inflammation or IH was seen in CP arterial grafts. The absence of early IH or inflammation suggests that CP small diameter arteries may perform better than many currently available allograft tissues and synthetic prosthetics.