PubMed Health⌕ Search

Biomedical subjects

R M Meffert

Publications and source records attributed to R M Meffert.

At least 19 recordsLinked to original sources

Clinical evaluation of anorganic bovine bone xenograft with a bioabsorbable collagen barrier in the treatment of molar furcation defects.

The purpose of this study was to compare Bio-Oss (BO), an anorganic bovine bone xenograft, in combination with Bio-Gide (BG), a bioabsorbable collagen barrier, to open-flap debridement (OFD) surgery in human mandibular Class II furcation defects. A total of 31 furcations (18 treatment, 13 control) in 21 patients were treated. There was a statistically significant improvement in most clinical indices for the BO/BG group, with minimal improvement noted for the OFD group. Vertical probing depth reduction of 2.0 mm and horizontal probing depth reduction of 2.2 mm were noted for the BO/BG group, with 0.3 mm and 0.2 mm reductions, respectively, noted for OFD. Hard tissue measurements showed 2.0 mm of vertical furcation bone fill for BO/BG and 0.5 mm for OFD. The BO/BG group had 3.0 mm of horizontal furcation bone fill, and the OFD group had 0.9 mm. The BO/BG group had a defect resolution of 82.7%; 42.5% was noted for the OFD group. There was a statistically significant difference between BO/BG and OFD in all soft and hard tissue measurements with the exception of attachment level, recession, and alveolar crest resorption.

Absorbable Implants↗

Clinical evaluation of wound healing following multiple exposures to enamel matrix protein derivative in the treatment of intrabony periodontal defects.

BACKGROUND: Multiple exposures to enamel matrix protein derivative (EMD) during periodontal therapy have been shown to be safe for the patient. The purpose of this study was to clinically determine if an altered course of wound healing would occur after multiple exposures to EMD in the treatment of intrabony defects. A secondary aim was to assess the efficacy of EMD in probing depth reduction and clinical attachment level gain. METHODS: Thirty-two systemically healthy patients (18 females, 14 males, 33 to 69 years old) who were being treated for moderate to advanced periodontal disease were selected for the study. Surgical procedures involving 2 sites were separated by at least 8 weeks, and wound healing comparisons were made between the first and second procedure. Patients were given a diary card the day of surgery, which consisted of questions concerning the presence and severity of headaches, root hypersensitivity, tooth pain, swelling, and itching. Patients were also examined at postoperative visits to clinically assess wound healing and discuss responses to the questionnaire. Soft tissue measurements were taken the day of surgery and 6 months postoperatively to ascertain probing depth reduction (PD) and gains in clinical attachment levels (CAL). RESULTS: The results revealed no clinically detectable reaction that could not be attributed to normal postoperative sequelae. There were no differences in reported symptoms between patient gender, first and second procedures, or intrabony and non-intrabony defects. Smokers were found to have a statistically significantly higher incidence of severe symptoms in root hypersensitivity, tooth pain, and swelling compared to non-smokers (n = 21). The mean probing depth reduction was 3.8 +/- 1.5 mm (2 to 9 mm), while the mean clinical attachment level gain was 2.8 +/- 1.7 mm (0 to 8 mm). CONCLUSIONS: The findings of this study demonstrate that EMD is a clinically safe product to use in the treatment of periodontal defects and that multiple uses do not have a negative impact on periodontal wound healing. In addition, a statistically significant gain in clinical attachment and reduction in probing depth were demonstrated.

Adult↗

Where's the rush?

Explore the source record for details and available documents.

Bone Density↗

Why do dental implants fail? Part II.

Dental implant failure has led to continuous innovations of various implant systems and to different interceptive treatment modalities. These concerns have also led to selection of implant designs that best suit the various types of bone. A checklist has been created to facilitate collection of data on the different factors associated with dental implant failure. The data gathered from this list are the basis of a multinational statistical analysis. This analysis will provide accurate information about the percentage of each element causing implant failure. Different causes of failure, such as host factors, surgical placement, and improper implant selection, were reviewed in Part I of this two-part series. This article discusses failure categories in terms of etiology, failure mode, failure type, failure origin, failure timing, responsible personnel, and different tissue types.

Dental Implantation, Endosseous↗

Ceramic-coated implant systems.

Practitioners have used hydroxyapatite-coated (HA-coated) endosseous and subperiosteal implants in various forms for many years. These have included root forms in both screw and cylindrical shapes, blades, and subperiosteals. The clinical predictability remains controversial and subject to claims and counterclaims. The early days of dental implantology involving root-form implants recommended their placement in fully edentulous cases only, and anterior to the maxillary sinus and mental foramen. Today's philosophy and rationale of dental implantology include the placement of a single implant replacing a missing natural tooth (especially where the teeth adjacent to the edentulous site have no caries or restorative experience). Implants are used to replace the natural dentition in one quadrant/segment, often preceded or accompanied by ridge augmentation and/or sinus grafting if sufficient bone is not present. So we have to address the clinical predictability of survival in terms of indications, quantity, and quality of bone. Clinical data and experience suggest that hydroxyapatite-coated (HA) dental implants may (and possibly should) be used in (1) Type IV bone, (2) fresh extraction sites, (3) grafted maxillary and/or nasal sinuses, or (4) with short implants (< or = 10 mm in length).

Alveolar Process↗

Comparison of bioactive glass to demineralized freeze-dried bone allograft in the treatment of intrabony defects around implants in the canine mandible.

BACKGROUND: The purpose of this study was to evaluate and compare the healing of different bone grafting materials adjacent to titanium plasma-sprayed (TPS) endosseous dental implants. METHODS: Implant osteotomy sites were prepared and standardized 3-walled intrabony defects (3 mm x 5 mm x 5 mm) were created at the mesial of each implant site. Thirty-two TPS implants were placed in edentulous mandibular ridges of the 4 dogs. Periodontal dressings were placed in the defect sites so as to create a defect simulating bone loss around an implant. After 3 months, the periodontal dressing was removed, the defect sites debrided and evaluated for size, and intramarrow penetration performed. The graft materials tested were 1) canine demineralized freeze-dried bone allograft (cDFDBA); 2) bioactive glass granules of a broad size range 90 to 710 microns (BRG); and 3) bioactive glass granules of narrow size range 300 to 355 microns (NRG). One site on each side of the mandible was not filled and served as a control. Dogs were sacrificed 4 months after graft placement. RESULTS: Histologically, differences in percent bone-to-implant contact in the defect area were observed between the treatment groups. cDFDBA>control=BRG=NRG with statistical significance found between cDFDBA and control (P = 0.0379), but no statistically significant difference between control or either bioactive glass material. When comparing percent bone height fill of the defect in the grafted area, cDFDBA (65.7%) was significantly better than the control (48.9%; P < or = 0.05) with no statistically significant difference between control, broad range bioactive glass (57.3%) and narrow range bioactive glass (56.6%). When total bone area was measured, the percentage of new bone in the grafted area was cDFDBA (42.1%), broad range glass (33.1%) and narrow range glass (22.6%) with significance found between cDFDBA and NRG (P = 0.0102). The content of residual graft particles in soft tissue was significant (P = 0.0304) between cDFDBA (1.4%) and NRG (11.4%) with no significant difference between graft material for residual particle content in bone tissue. CONCLUSIONS: The results of this study indicate that percent bone-to-implant contact and percent bone height fill in an intrabony defect around titanium plasma-sprayed implants are statistically significantly higher with the use of DFDBA when compared to bioactive glass material.

Alveolar Bone Loss↗

Why do dental implants fail? Part I.

Many factors are attributed to failure of the dental implant, either directly or indirectly. The focus of this article is to define the causation of dental implant failure, as well as to present an evaluation of the implant literature regarding etiology, classification, management, and treatment of implant failures. This article will highlight the initial signs of implant failure with a view of some clinical cases in terms of classification and degrees of implant failure. Finally, a dental implant failure checklist is formulated to guide the practitioner in defining the cause of implant failure, be it infective or noninfective, and to establish percentages and frequency of occurrence. The checklist applies to all implant systems and will help to determine the factors responsible for causation and the repair procedures, whether they are at the surgical or restorative phases. The definition of implant failure is set forth in terms of ailing, failing, failed, and surviving implants, and the appropriate treatments and dispositions are outlined.

Bone Diseases↗

Treatment of oral granulation tissue with the flashlamp pulsed dye laser.

BACKGROUND: Surgical excision and debridement is the standard therapy for cutaneous and intraoral pyogenic granulomas (PGs). Occasionally the mass of granulation tissue proves unresponsive to the usual treatment methods. OBJECTIVE: We report a case in which the flashlamp pulsed dye laser (PDL), previously reported as useful in cutaneous PGs, was used in a patient with persistent granulation tissue around dental implant posts. METHODS: An illustrative case is presented with a brief discussion of the use of lasers in dentistry and in the treatment of PGs. RESULTS: Previously resolute tissue responded well to a series of treatments with the PDL. CONCLUSION: The PDL may have utility in this oral condition, providing a new venue for cooperation between dentists and dermatologists.

Aged↗

Clinical evaluation of bioactive glass in the treatment of periodontal osseous defects in humans.

The purpose of this study was to compare the use of bioactive glass to demineralized freeze-dried bone allograft (DFDBA) in the treatment of human periodontal osseous defects. Fifteen systemically healthy patients (6 males and 9 females, aged 30 to 63) with moderate to advanced adult periodontitis were selected for the study. All patients underwent initial therapy, which included scaling and root planing, oral hygiene instruction, and an occlusal adjustment when indicated, followed by re-evaluation 4 to 6 weeks later. Paired osseous defects in each subject were randomly selected to receive grafts of bioactive glass or DFDBA. Both soft and hard tissue measurements were taken the day of surgery (baseline) and at the 6-month re-entry surgery. The clinical examiner was calibrated and blinded to the surgical procedures, while the surgeon was masked to the clinical measurements. Statistical analysis was performed by using the paired Student's t test. The results indicated that probing depths were reduced by 3.07 +/- 0.80 mm with the bioactive glass and 2.60 +/- 1.40 mm with DFDBA. Sites grafted with bioactive glass resulted in 2.27 +/- 0.88 mm attachment level gain, while sites grafted with DFDBA had a 1.93 +/- 1.33 mm gain in attachment. Bioactive glass sites displayed 0.53 +/- 0.64 mm of crestal resorption and 2.73 mm bone fill. DFDBA-grafted sites experienced 0.80 +/- 0.56 mm of crestal resorption and 2.80 mm defect fill. The use of bioactive glass resulted in 61.8% bone fill and 73.33% defect resolution. DFDBA-grafted defects showed similar results, with 62.5% bone fill and 80.87% defect resolution. Both treatments provided soft and hard tissue improvements when compared to baseline (P < or = 0.0001). No statistical difference was found when comparing bioactive glass to DFDBA; however, studies with larger sample sizes may reveal true differences between the materials. This study suggests that bioactive glass is capable of producing results in the short term (6 months) similar to that of DFDBA when used in moderate to deep intrabony periodontal defects.

Adult↗

Issues related to single-tooth implants.

Many practitioners place single-tooth implants when the teeth adjacent to the edentulous space are intact, free of caries and have had no restorations, and the patient is reluctant to wear a removable appliance for physical or psychological reasons, or both. The main exclusionary factors for a single-tooth dental implant are insufficient bone quantity, poor bone quality and insufficient vertical interarch space to accommodate the prosthodontic components of the implant.

Biocompatible Materials↗

Histologic evaluation of the LaminOss osteocompressive dental screw: a pilot study.

This animal study compared the response of canine mandibular bone using the orthopedic principle of osteocompression by the function of an immediately loaded dental implant vs an unloaded dental implant of the same design and size. Two dogs were partially edentulated in the mandible. A total of 8 osteocompressive screw implants, 2 per quadrant were placed and evaluated histomorphometrically after 3 days in 1 dog and after 3 months in the second dog. The second dog had a two-unit fixed bridge placed immediately postsurgically in occlusal function on the right side; on the left side, the implants were splinted out of occlusion as a control. Histologically, no bone necrosis was observed at the implant interface by any of the 8 implants for either period as a direct result of the 4-mm-diameter by 13-mm-length implant design. Clinical parameters did not differ among the implants; however, at 3 months, the immediately loaded implants demonstrated more than twice the amount of bone density at their surfaces compared to the unloaded implants of the same design. Future human clinical research would be necessary to provide a meaningful statistical analysis to validate the importance of this implant design and the function of osteocompression.

Animals↗

Do implant surfaces make a difference?

The synthetic biomaterials commonly used as an interface or surface for soft- and hard-tissue attachment and integration are commercially pure titanium, titanium alloy (usually Ti6A14V), and hydroxyapatite. This review attempts to address the following questions: Do the epithelium and connective tissue attach or adapt to these synthetic surfaces? Is there a seal or just a cuff in terms of the soft-tissue interface? Is hydroxyapatite, commercially pure titanium, or Ti6A14V more predictable and retentive? Is one better than the other or are all the same? Is there an advantage of one surface over the other in terms of bone-to-implant contact or shear strength when stressed? How about bone density and fixture length; is one surface better than any other?

Alloys↗

Periodontitis vs. peri-implantitis: the same disease? The same treatment?

The microbial flora in the natural dentition sulcus/pocket and the implant crevice/pocket is very similar in both health and disease. In health, coccal forms predominate, and in disease, large numbers of Gram-negative pathogens are associated with both tooth and implant. It has also been demonstrated that the bacteria in the partially edentulous implant case may be more pathogenic (especially Gram-negative rods and spirochetes) than in the fully edentulous case, indicating a possible seeding mechanism from tooth pocket to implant crevice. Detoxification procedures involving the use of tetracycline and citric acid prior to regenerative procedures with the use of barrier membranes and grafting materials are necessary, and the same problems attendant to premature exposure of the barrier membrane(s) in the natural dentition situation apply to the implant case. It is apparent that periodontitis = peri-implantitis in etiology and therapy.

Anti-Bacterial Agents↗