Withstanding shock loads in activated sludge treatment by pre-exposure to low H2S concentrations.

An activated sludge pilot plant was used to acclimatise sludge to a low dose of H2S gas. Sludge samples from different types of treatment works were compared with acclimatised and unaclimatised sludges using batch absorption tests. The effects of sludge source and acclimatisation on the ability of the sludge to withstand shock loads of 50 ml l(-1) H2S were evaluated. Sludge that had been acclimatised to 5 ml l(-1) H2S in the air supply removed 70% of a 50 ml l(-1) load in a batch reactor after three sludge ages of acclimatisation. Pre-exposure to low H2S concentrations enabled the bacterial community to maintain a sufficient sulphide-degrading population to retain acclimatisation and degrade subsequent high loads which are toxic to unacclimatised sludge. Acclimatisation to H2S is therefore mainly an effect of selection pressure on the mixed bacterial population, which suggests that the H2S removal capacity of different types of activated sludge will converge after acclimatisation, irrespective of their initial degradative abilities.

Absorption↗

Use of a chemical sensor array for detecting pollutants in domestic wastewater.

A chemical sensor array (consisting of 8 conducting polymers) was used to continuously monitor for the presence or absence of industrial pollutants in the headspace of wastewater generated from an on-line flow-cell. A domestic wastewater (Cranfield University sewage works) was dosed with diesel to stimulate the presence of an intermittent discharge in a wastewater influent. Response patterns between the sensors were used to detect for the presence of organic compounds in the wastewater. Correlations between the sensor response patterns or fingerprints were also analysed using principal component analysis. The results clearly demonstrate that a chemical sensor array can rapidly identify the presence of organic compounds (such as diesel) in a wastewater matrix and could be further developed to monitor for industrial pollutants at the inlet of a sewage works.

Automation↗

Dinitrogen oxide production by a mixed culture of nitrifying bacteria during ammonia shock loading and aeration failure.

A number of experiments was conducted in order to establish if N(2)O in the exhaust gas from an aerobic consortium of nitrifiers could be used as an indicator for monitoring the nitrification process. Laboratory-scale experiments with an activated sludge system showed a strong correlation between ammonia shock loads and both the concentration of N(2)O and the rate of increase of N(2)O in the exhaust gas for shock loads less than 1.60 mg ammonical nitrogen (NH(3)-N) per g total suspended solids (TSS). For greater ammonia shock loads, correlation was found between build-up of nitrite in the aeration tank and the concentration of N(2)O in the exhaust gas from the tank. When subjecting the system to aeration failure, a similar pattern was seen, with a correlation between nitrite build-up in the aeration tank and increases in the concentration of N(2)O in the exhaust gas. The results from this work suggest that the changes in N(2)O concentration in the exhaust gas from a nitrifying process may be a useful parameter for monitoring such processes.

Aerobiosis↗

Dinitrogen oxide detection for process failure early warning systems.

A number of experiments were conducted in order to establish whether the concentration of N2O in the off-gas from an activated sludge pilot plant could be used as a indicator for monitoring the nitrification process and as an early indication of ammonia appearing in the plant effluent. A strong correlation was found between ammonia shock loads and the concentration of N20 in the off-gas from the aeration tank for ammonia shock loads and dissolved oxygen depletion. When subjecting the experimental setup to doses of a nitrification inhibitor (allylthiourea) a similar pattern was seen with a correlation between nitrite build up in the aeration tank and concentration increase of N2O in the off-gas from the aeration tank. The results from this work suggest the concentration and the changes in the concentration of N2O in the exhaust gas from a nitrifying process may be a useful parameter for monitoring nitrifying activated sludge processes.

Ammonia↗

Odour measurements for sewage treatment works.

Public concern over odours from sewage treatment works is increasing. More people are being exposed to odours, due to development around existing works or construction of new works. Increased awareness of both the environment and individual rights has meant people are now more likely to complain. Odour abatement and control is a major issue for sewage works operators. To control odours, they must first be measured. This is no easy task as response to odours is subjective. Our understanding of the sense of smell is incomplete, and there is no single measure that will directly relate to the likelihood of complaint. Odour measurement has often been regarded as an art as opposed to a science. Odour measurement techniques fall into two classes. Sensory measurements employ the human nose and measure the effects of the odour as perceived by an observer. Analytical measurements characterise odours in terms of their chemical composition and attempt to quantify the odorants present. Both methods are less than ideal--sensory measurements can be overly subjective and the interpretation of results requires care. Analytical measurements are complicated by the large number of odorants present, often at concentrations close to detection limits. Our incomplete understanding of odour perception makes linking analytical and sensory measurements difficult. This paper reviews the methods applied to sewage treatment works odour measurement. Sensory and analytical measurements are reviewed, along with a recent development, the electronic nose.

Humans↗

Direct molecular hydrogen sulphide scrubbing with hollowfibre membranes.

The emission of hydrogen sulphide is a major problem associated with anaerobic treatment of sulphate and sulphite containing wastewaters. Conventional absorbing processes, such as packed towers, spray towers or bubble columns, are all constrained by factors such as flooding and foaming. Membrane systems, on the other hand, enable independent control of the liquid and gas flow rate and a step change order of magnitude increase in the specific surface area of the contact process. The membrane acts as a gas absorber with a design similar to a shell and tube heat exchanger. On the other hand, they are limited by facets of the membrane such as its resistance to mass transfer and permselectivity, as well as its cost. The work presented in this paper refers to an absorption process based on a non-wetted hollow fibre membrane for the scrubbing of hydrogen sulphide from air, with water as the contact solvent. Results presented describe the performance of the unit in terms of overall transfer and outlet liquid concentration as a function of circulation regime, gas flow rate, liquid flow rate and specific surface area. In particular, results are presented using traditional plots of Sherwood number (Sh) against Graetz (Gr) number for the liquid flowing in the lumens, such that experimental and available empirical descriptions of the process performance are directly compared. Results suggest that, as expected, very efficient mass transfer is obtained. However, the mass transfer was found to reach a maximum value against Gr, contrary to available empirical models.

Absorption↗

Simultaneous activated sludge wastewater treatment and odour control.

Lab-scale tests were used to determine the amount of H2S that can be treated using a range of different activated sludges. Static vessels were used to study the effects of different H2S concentrations (5, 25, 50 and 75 ppm). The data indicated that odour control may be carried out using certain types of sludge, but sludge type, e.g. carbonaceous, nitrifying, with or without coagulant, affects removal efficiency. The presence of the biomass resulted in greater H2S removal than the use of wet scrubbing and the adverse effects on mixed liquor were negligible. A pilot plant was used to study the removal efficiencies of activated sludge diffusion using a typical wastewater treatment plant H2S concentration and investigated the effects that the diffusion of H2S had on the process performance. Results indicated that the levels of H2S produced by other unit processes on a wastewater treatment site (approximately 5 ppm) can be treated using activated sludge diffusion without compromising the performance of the wastewater treatment process. The only effects on the activated sludge plant observed were: (1) nitrification was interrupted briefly as H2S diffusion commenced and (2) the species' diversity in the sludge decreased.

Air Pollution↗

Sensor arrays: an inspired idea or an objective measurement of environmental odours?

The measure of annoyance odours from sewage tratment, landfill and agricultural practise has become highly significant in the control and prevention of dorous emissions from existing facilities and its crucial for new planning applications. Current methods (such as GC-MS analysis, H2S and NH3 measurements) provide an accurate description of chemical compositions or act as surrogates for odour strength, but tell us very little about the perceived effect, whereas olfactometry gives the right human response but is very subjective and expensive. The use of non-specific sensor arrays may offer an objective and on-line instrument for assessing olfactive annoyance. Results have shown that sensor array systems can discriminate between different odour sources (wastewater, livestock and landfill). The response patterns from these sources can be significantly different and that the intensity of sensor responses is proportional to the concentration of the volatiles. The correlation of the sensors responses against odour strengths have also shown that reasonable fits can be obtained for a range of odour concentrations (100-800,000 ou/m3). However, the influence of environmental fluctuations (humidity and temperature) on sensor baselines still remains an obstacle, as well as the need for periodic calibration of the sensory system and the choice of a suitable gas for different environmental odours.

Agriculture↗