PubMed Health⌕ Search

Biomedical subjects

R Müller-Rath

Publications and source records attributed to R Müller-Rath.

15 recordsLinked to original sources

[Liver laceration following a kick in a soccer game].

Severe intraabdominal injuries in soccer are very rare. We present the case of an 18 year old soccer player who suffered from a grad IV liver laceration following a kick during a soccer game. After primary explorative laparatomy and liver packing in a hospital nearby the patient was transferred to our clinic. Following CT scan the injury was treated by suture of liver parencym lacerations, argon laser coagulation and pile duct repair. In soccer severe intraabdominal injuries should be expected following players collision at high velocity or kicking with the foot or the knee.

Adolescent↗

Comparison of modern marker proteins in serum and synovial fluid in patients with advanced osteoarthrosis and rheumatoid arthritis.

Numerous studies have focused on the significance of modern marker proteins in the synovial fluid of the knee joint and in the serum both, for osteoarthritis (OA) and rheumatoid arthritis (RA). The relationship between the serum concentrations and the concentrations in the synovial fluid is still unclear. Synovial fluid and serum samples were obtained from 13 patients with advanced OA and from 8 patients with severe RA and concentrations of MMP-1, MMP-3, MMP-13, TIMP-1, COMP and MIA/CD-RAP were determined. All values were normalized against the total protein concentrations. Serum concentrations of MMP-13 in the RA-group were statistically higher than the synovial values (P<0.05). MMP-13 was the only marker protein that revealed distinct higher levels in the serum than in the synovial fluid. The study design allows only conclusions about advanced stages of RA and OA. Longitudinal investigations may provide further information about the value of MMP-13 as a potential marker to monitor the course of RA and OA.

Aged↗

Diagnostic values of positron emission tomography versus triple-phase bone scan in hip arthroplasty loosening.

INTRODUCTION: The most frequent complications of total hip arthroplasty are septic and aseptic wear-induced loosening. A reliable differentiation between septic and aseptic loosening with current diagnostic tools is not possible. Therefore, we examined the diagnostic valency of positron emission tomography (PET) with (18)F-fluorodeoxyglucose (FDG) in cases of septic or aseptic hip arthroplasty loosening compared with conventional triple-phase bone scan (TPBS). MATERIALS AND METHODS: Fifty patients with 70 total hip replacements (symptomatic n=50, asymptomatic n=20) were examined by means of FDG-PET and TPBS to detect septic and aseptic loosening and differentiate between the two. A differentiated algorithm subdivided into categories I-V was developed for FDG-PET. Additionally, standardized uptake values (SUV) were calculated from the lesion with the highest FDG uptake. Interpretations of the TPBS were done according to the criteria described by Wilson. The final diagnosis was based on operative findings including microbiological and histological examinations (n=50), while the remaining asymptomatic arthroplasties (n=20) were integrated into a clinical follow-up (> or =9 months). RESULTS: Sensitivity/specificity of FDG-PET was 91%/92% (accuracy 91%) compared with 78%/70% (accuracy 74%) for TPBS. A high correlation could be proved between FDG-PET investigation and operative histopathological findings (r(Spear)> or =0.9). No significant differences were found regarding cemented and uncemented implanted hip arthroplasties (p> or =0.05). Calculation of the SUV turned out to be inappropriate as a sole criterion for image interpretation. CONCLUSION: FDG-PET is a promising, highly accurate examination method to detect polyethylene and metal wear-induced chronic inflammation followed by periprosthetic osteolysis. In addition, FDG-PET has a significantly higher sensitivity and specificity than TPBS for differentiating between aseptic loosening and infection.

Adult↗

[Risk of injury in and adolescent and junior competitive karate].

Increasing professionalism in competitive karate has led to a specific injury pattern. The aim of our study was to investigate the injury pattern in junior competitive karate and to evaluate the prophylactic effect of fist padding. During the 4 (th) Junior World Championships of the World Karate Confederation (WKC) 2004 235 karate fights were observed and injury-related data were recorded. Fist padding was used in 183 fights, 52 fights were carried out without. In 22 % of all fights we saw an injury. Most of them were mild injuries of the head and face: 32 bruises of the face (13 with epistaxis), 7 facial lacerations and 3 concussions (mild brain injury). 14 fights were stopped due to an injury. Only in the category male 18 - 20 years a higher rate of injuries was seen without fist padding (shobu ippon) compared to shobu sanbon (with fist padding). The injury pattern of junior competitive karate is comparable to senior karate. Fist padding does not generally reduce the incidence or severity of injuries.

Adolescent↗

[Teutschländer disease. A rare benign differential diagnosis of proliferative space-occupying lesions in the periarticular soft tissue].

The tumoral calcinosis (synonym: Teutschländer disease) is a very rare benign metabolic dysfunction of unknown etiology. It manifests principally as massive subcutaneous soft tissue deposits of calcium phosphate near the large joints and is also characterized by slow progressive growth. Causally, a disturbance of the calcium and phosphate metabolism/balance with, among others, autosomal dominant heredity is suspected. It appears frequently in the black African population in all age groups, but preferentially in the 1st and 2nd decades of life. Medical help is most frequently sought because of increasing tumor size causing displacement and consecutive pain as well as decreased joint play. We present here a case of Teutschländer disease in a 50-year-old woman on long-term hemodialysis and describe the clinical, radiological, and pathological signs of this rare disease. Subsequently, speculative etiology, differential diagnostic considerations as well as the therapeutic interventions for tumoral calcinosis are discussed taking into consideration the current literature.

Calcinosis↗

[Competitive karate and the risk of HIV infection--review, risk analysis and risk minimizing strategies].

Bleeding facial injuries are not uncommon in competitive karate. Nevertheless, the risk of an infection with HIV is extremely low. Guidelines about the prevention of HIV infections are presented. Especially in contact sports and martial arts the athletes, judges and staff have to recognize and employ these recommendations. Bleeding wounds of the hands due to contact with the opponents teeth can be minimized by fist padding.

Athletic Injuries↗

[FDG PET as an early nuclear medical diagnostic tool for aseptic wear-induced loosening of hip joint endoprostheses--a report of two cases].

To date, 2-[F-18]fluoro-2-deoxy-D-glucose PET (FDG PET) is used as a tool in oncology as well as myocardiological and cerebral functional diagnostics in the clinical routine. False positive results of tumor search imply new possibilities for use in diagnostics of inflammation. The two case reports presented here on aseptic loosening of endoprostheses caused by the rub of polyethylene with histological and immunohistological refurbishing call attention to the possible diagnostic valency of FDG PET as an early warning system regarding aseptic artificial limb loosening induced by the rub of polyethylene. By quantification of glucose metabolism with the "standard uptake value" (SUV) as well as specific storage samples from around the artificial limb, it is the aim of our study group in further examinations to develop an algorithm which permits to distinguish between septic and aseptic loosening.

Acetabulum↗

[Injury profile in modern competitive karate--analysis of 1999 WKC-Karate World Championship Games in Bochum].

Competitions in Karate are either carried out as Shobu sanbon (with fist padding) or Shobu Ippon (without fist padding). Aim of this study was to gain current data on injuries in modern competitive Karate and to compare the two different competitive systems. During the WKC-Karate-World-Championships held from June 12-13 1999 at Bochum, 392 bouts were carried out. Every injury that was seen by the tournament doctor was registered. 142 competitors sustained 168 injuries: 141 mostly minor contusions of the head and throat, 12 facial lacerations, 3 knock-outs (mild brain injury), 3 thoracal contusions, 1 midfoot fracture and 9 other blunt injuries. We saw more injuries in Shobu Sanbon (146/302 bouts) than in Shobu Ippon (23/90). Most of the injuries (152) were caused by punches. In Shobu Sanbon, kicking techniques led to 17 injuries only. The injury pattern shown here is comparable to earlier studies. Severe injuries in competitive Karate are rare. The higher number of injuries in Shobu sanbon may be due to the longer fighting time and higher scoring. Fist pads used in Shobu Sanbon might also lead to a loss of control. Therefore, prophylactic fist padding to avoid injuries in competitive Karate has to be seen critically.

Adolescent↗

[[F-18]-fluorodeoxyglucose (FDG) positron emission tomography (PET) as a diagnostic for hip endoprosthesis loosening].

AIM: The purpose of this study was to examine the FDG-PET in respect of its diagnostic valency with regard to septic/aseptic loosening of lower limb prostheses. METHOD: 28 patients with 41 lower limb prostheses were examined by means of FDG-PET to evaluate septic/aseptic loosening of their hip prostheses. Therefore, a differentiated FDG-PET result interpretation subdivided into five categories was developed. The final diagnosis was based on operative findings with following culture and histological outcome. RESULTS: The worked-out categories showed a high agreement to the intraoperative macroscopic and histological results (n = 23 correctly positive, n = 1 false positive, n = 1 correctly negative and n = 3 false negative). CONCLUSION: With a subtly differentiated interpretation (categories I - V) of the qualitative glucose metabolism safe statements can be made regarding septic/aseptic endoprostheses loosening. This was impressively confirmed by the agreement of the FDG results with the histological results.

Aged↗

[The cement-free modular revision prosthesis MRP-hip revision stem prosthesis in clinical follow-up].

INTRODUCTION: We present prospective medium-term results of the modular revision prostheses "MRP-TITANIUM". MATERIAL AND METHODS: 45 patients (n = 48 prostheses) were evaluated. The mean follow-up was 4.7 years (min.-max.: 1.0-9.0 years). Pre- and postoperatively the Harris hip score (differentiated to Paprosky I-III) was examined. 66.67 % of the cases had extensive bony defects (> or = Paprosky II b). By means of X-ray examinations, the stability of the prostheses, periprosthetic bone remodelling, the presence of radiolucent lines as well as bone defect regeneration were assessed postoperatively. RESULTS: The mean Harris hip score improved from 25.6 preoperative to 71.4 postoperative (p < or = 0.05). In 44 cases the X-ray showed stable fixation without secondary migration. In one case the stem (stand time 2.36 years) was revised due to secondary migration (> or = 5 mm). The survival rate (Kaplan-Meier) was 97 %. Bone transplantation with consecutive defect regeneration was (n = 30) complete in all cases. In six cases (12.5 %) a postoperative dislocation occurred with subsequent successful closed reposition four times (8.3 %). In two cases (4.2 %) an open reposition was done with correction of the antetorsion angle of the prostheses. CONCLUSION: The "MRP-TITANIUM modular revision prostheses" has proved to be reliable in cases of revision surgery with extensive bony defects. The failure rate was 2.1 % for 48 prospectively examined prostheses.

Aged↗

[Meniscus replacement: current aspects in the field of tissue engineering].

Tissue engineering offers new opportunities for meniscus repair and replacement. In this field different approaches are being studied to genererate a meniscus subsitute by a combination of a matrix scaffold, cells and specific stimuli. MENISCUS REPLACEMENT BY ACELLUAR MATRICES: For meniscus replacement the matrix material has to meet high biomechanical demands. Besides implant geometry, the material properties and a secure intraarticular attachment are important preconditions for implant function. A collagen scaffold has already been applied clinically for partial meniscus replacement. Scaffolds made of synthetic, bioabsorbable polymers and small intestine submucosa have been employed in animal studies. Following implantation, matrices are invaded by cells and undergo a process of remodeling. Formation of fibrocartilage repair tissue has been observerd. The biomechanical quality of implants and their effect on cartilage preservation have to be studied further. CELLULAR SEEDING OF MATRICES FOR MENSICUS REPLACEMENT: Advanced biological and biomechanical implant quality might be achieved by seeding matrices with cells in vitro. However, the ideal type of cell for this purpose has not yet been identified. Autologous mensicus cells, articular chondrocytes and mesenchymal stem cells represent possible cellular sources. Additional stimuli, such as cytokines and mechanical forces, and techniques of genetic engineering might further contribute to enhance the quality of engineered tissue.

Biocompatible Materials↗

[What factors influence the results of ACT when the indication limits are exceeded?].

AIM: The present study evaluates the results of ACT at the knee joint with transgression of the usual spectrum of indications and points out the possible limits of the method. METHODS: In 20 of a total of 71 patients the indication limits of ACT were exceeded. The clinical follow-up over two years was related to the localisation, size, adjacent cartilage, previous and additional operations and the quality of the transplanted chondrocytes. RESULTS: The average patient age at time of operation was 41.1 years (24 to 55 years). The average defect size was 7.9 cm (2) (3.75 to 14 cm (2)). In the analysed group outside of the indication limits of ACT half of the patients showed good or excellent results at clinical follow-up after 2 years. 10 patients, however, assessed the clinical situation as fair or poor. Within this group 5 patients showed a minimum of two lesions. In 6 patients the treated defect was not completely surrounded by an adjacent cartilage shoulder. In 7 cases the meniscus at the site of the lesion had been partially removed in a previous operation and osteoarthrosis or kissing lesions were detected in 4 cases. The persistent good cell quality had no negative influence on the postoperative results. CONCLUSION: The results after ACT are influenced by the adjacent cartilage shoulder, kissing lesions, previous meniscectomy and osteoarthrosis. This may limit the indications of the method.

Adult↗

[Isolated bilateral Sternocostoclavicular Hyperostosis (SCCH) with a pathological clavicular fracture--a 10-year follow-up].

The presented case demonstrates the clinical and radiological course of a woman suffering from bilateral sternocostoclavicular hyperostosis (SCCH) from early changes to a spontaneous clavicula fracture after 10 years. SCCH is characterised by a chronic recurrent painful swelling of the sternoclavicular region due to an aseptic inflammation and hyperostosis of the clavicula, sternum, upper ribs and the adjacent soft tissues. Frequently the picture is accompanied by cutaneous and other skeletal symptoms. The disease can be part of the SAPHO (synovitis, acne, pustulosis, hyperostosis, osteitis) syndrome. The chronic process is represented by the typical "bull horn sign" in a bone scan. NSAIDS should represent the first line treatment.

Anti-Inflammatory Agents, Non-Steroidal↗

[First clinical experiences with a novel 3D-collagen gel (CaReS) for the treatment of focal cartilage defects in the knee].

AIM: In this prospective study we present a novel technique of matrix-based chondrocyte transplantation for the treatment of focal cartilage defects. METHOD: 22 patients with chondral or osteochondral femoral defects were treated with 3D-collagen type-I gel seeded with autologous chondrocytes (CaReS). Overall handling of this novel method is described, and results after 2 years follow-up with regard to the ICRS-score are presented. RESULTS: 14 patients were treated because of a focal chondral lesion, in 8 cases subchondral bone had to be reestablished. The average defect size was 6 cm(2). In all cases cell-seeded matrix samples could be fixed with fibrin glue without any problems. The average surgery time was 69 min, length of the surgical approach was 8.2 cm. No surgery-specific problems had to be observed. A significant improvement in IKDC-score, functional score and overall rating after 3 or 6 months up to 2 years follow-up was detected. After 2 years post-OP 13 Patients were evaluated and matrix-based defect treatment by CaReS was rated good to excellent by 84.6 % of the patients. CONCLUSION: Defect treatment with cell-seeded 3D-collagen gel is easy to handle with a good clinical outcome after 2 years follow-up. Further investigations with higher patient number, longer follow-up time and histological and biomechanical sample analysis are needed in order to establish this method as an improvement of conventional ACT.

Adolescent↗

[Cemented total knee arthroplasties].

INTRODUCTION: The aseptic loosening of cemented total knee arthroplasties is still an unsolved problem. In this regard, the hydrolysis resistance in the metal-to-bone cement interface is of major importance. MATERIAL AND METHODS: Cemented pre-treated tibia components coated by means of a silica/silane interlayer system of the model "Columbus PS" were dynamically loaded with the help of a knee-simulator similar to DIN ISO 14243. After loading, the components were microscopically analysed concerning debonding in the metal-to-bone cement interface as well as with regard to cement mantle defects. These data were matched with uncoated "Columbus PS" components. Unloaded coated and uncoated tibia components acted as a control. RESULTS: In comparison with uncoated tibia components, the pre-treated and coated ones yielded a highly significant reduction of cement defects (p < 0.01) as well as a significant reduction of debonding in the metal-to-bone cement interface (p < 0.05). CONCLUSION: By means of the silica/silane interlayer system for cemented tibia components, a hydrolytic debonding in the metal-to-bone cement interface with subsequent mechanical loosening and consecutive early cement mantle failure can be significantly reduced. This could lead to an increased long-term stability of the metal-to-bone cement compound with decreased aseptic loosening in clinical use.

Adhesiveness↗