[Partial k-space sampling with zero filling used with phase-contrast flow measurements: in vivo and in vitro validation].

PURPOSE: To validate the technique of partial k-space sampling and zero filling with phase-contrast flow measurements as compared to measurements with full k-space sampling. MATERIALS AND METHODS: In vitro: A laminar flow phantom was utilized to evaluate the effect of partial k-space sampling on the accuracy, precision and signal-to-noise ratio of phase-contrast flow measurements. In vivo: The effect of partial k-space sampling on the quantification of cardiac output (n = 40 patients) and the duration of the scan were evaluated in the ascending aorta (n = 37) and pulmonary trunk (n = 34) in a prospective study. RESULTS: Partial k-space sampling resulted in an increase in the SNR by 2 % in vitro. The precision was altered by less than 1 %. Flow volumes were systematically overestimated by 3.5 %. No significant differences were found in the in vivo measurements of cardiac output. The scan duration was reduced by 34 % by utilizing partial k-space sampling. CONCLUSION: Partial k-space sampling can be used to reduce scan time without a significant decrease in the accuracy or precision of phase-contrast flow measurements in large arteries.

Arteries↗

High-field MR angiography on an in vitro stenosis model determination of the spatial resolution on 1.5 and 3T in correlation to flow velocity and contrast medium concentration.

Since the first description of coronary magnetic angiography (MRA) in the early of 1990, this method seems to be shaped us a promising noninvasive modality to view the coronary arteries. Since several years dedicated high-field MR systems up to 4T are available for human use. The aim of the study was the evaluation of an in vitro vessel model with defined stenoses on 1.5T and 3T. For imaging at 3T, we used a 3d gradient-echo-sequence (fast SPGR). Furthermore, we examined the influence of the flow velocity and the contrast medium concentration on the spatial resolution. The accurate detection of in vitro stenoses was possible in segments up to 0.6 mm at 3T, the best results were obtained at a flow velocity of 40 ml/min and a contrast medium concentration of 0.2 mmol/l. The influence of the contrast medium concentration was statistically not significant. These results show that the spatial resolution can be increased by the use of a high-field MR scanner. Further in vivo studies are necessary to eliminate the method's limitation in visualizing small distal vessel segments.

Blood Flow Velocity↗

Comparison of different cardiac MRI sequences at 1.5 T/3.0 T with respect to signal-to-noise and contrast-to-noise ratios - initial experience.

PURPOSE: To compare image quality, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) of different MRI sequences for cardiac imaging at 1.5 T and 3.0 T in volunteers. MATERIAL AND METHODS: 10 volunteers (5 male, 5 female) with a mean age of 33 years (+/- 8) without any history of cardiac diseases were examined on a GE Signa 3.0 T and a GE Signa 1.5 T TwinSpeed Excite (GE Medical Systems, Milwaukee, WI, USA) scanner using a 4-element phased array surface coil (same design) on the same day. For tissue characterization ECG gated Fast Spinecho (FSE) T (1)- (Double IR), T (1)-STIR (Triple IR) and T (2)-weighted sequences in transverse orientation were used. For functional analysis a steady state free precession (SSFP - FIESTA) sequence was performed in the 4-chamber, 2-chamber long axis and short axis view. The flip angle used for the SSFP sequence at 3.0 T was reduced from 45 degrees to 30 degrees to keep short TR times while staying within the pre-defined SAR limitations. All other sequence parameters were kept constant. RESULTS: All acquisitions could successfully be completed for the 10 volunteers. The mean SNR 3.0 T compared to 1.5 T was remarkably increased (p < 0.05) for the T (2) - (160 % SNR increase), the STIR-T (1)- (123 %) and the T (1)- (91 %) weighted FSE. Similar results were found comparing CNR at 3.0 T and 1.5 T. The mean SNR achieved using the SSFP sequences was more than doubled by 3.0 T (150 %), but did not have any significant effect on the CNR. The image quality at 3.0 T did not appear to be improved, and was considered to be significantly worse when using SSFP sequences. Artefacts like shading in the area of the right ventricle (RV) were found to be more present at 3.0 T using FSE sequences. After a localized shim had been performed in 5/10 volunteers at the infero-lateral wall of the left ventricle (LV) with the SSFP sequences at 3.0 T no significant increase in artefacts could be detected. CONCLUSIONS: In all cardiac FSE sequences, SNR and CNR at 3.0 T were found to be increased compared to 1.5 T without any major changes of the sequence parameters. The adjusted SSFP sequences fulfilled the expected increase in SNR at 3.0 T but showed no increase in CNR. On the contrary, the overall image quality did not change or was even found to be significantly lower for the SSFP and the FSE sequences at the free wall of the RV. Nevertheless, the results are encouraging for the use of 3.0 T for cardiac tissue characterization and new applications with progressing use of parallel imaging.

Adult↗

Human cardiac imaging at 3 T using phased array coils.

Using a two-element phased array receiver coil, single breath-hold, ECG gated cardiac images of signal-to-noise ratios up to 130 and contrast-to-noise ratios exceeding 35 between myocardium and blood were recorded at 3 T. At several locations within the myocardium, T*(2) and B(0) inhomogeneity were determined. Because of shorter T*(2) times and larger B(0) inhomogeneities attributable to enhanced susceptibility effects, real-time cardiac imaging, the use of spiral scans, and echo planar imaging are expected to be considerably more difficult at 3 T.

Artifacts↗

Comparison of four magnetic resonance methods for mapping small temperature changes.

Non-invasive detection of small temperature changes (< 1 degree C) is pivotal to the further advance of regional hyperthermia as a treatment modality for deep-seated tumours. Magnetic resonance (MR) thermography methods are considered to be a promising approach. Four methods exploiting temperature-dependent parameters were evaluated in phantom experiments. The investigated temperature indicators were spin-lattice relaxation time T1, diffusion coefficient D, shift of water proton resonance frequency (water PRF) and resonance frequency shift of the methoxy group of the praseodymium complex (Pr probe). The respective pulse sequences employed to detect temperature-dependent signal changes were the multiple readout single inversion recovery (T One by Multiple Read Out Pulses; TOMROP), the pulsed gradient spin echo (PGSE), the fast low-angle shot (FLASH) with phase difference reconstruction, and the classical chemical shift imaging (CSI). Applying these sequences, experiments were performed in two separate and consecutive steps. In the first step, calibration curves were recorded for all four methods. In the second step, applying these calibration data, maps of temperature changes were generated and verified. With the equal total acquisition time of approximately 4 min for all four methods, the uncertainties of temperature changes derived from the calibration curves were less than 1 degree C (Pr probe 0.11 degrees C, water PRF 0.22 degrees C, D 0.48 degrees C and T1 0.93 degrees C). The corresponding maps of temperature changes exhibited slightly higher errors but still in the range or less than 1 degree C (0.97 degrees C, 0.41 degrees C, 0.70 degrees C, 1.06 degrees C respectively). The calibration results indicate the Pr probe method to be most sensitive and accurate. However, this advantage could only be partially transferred to the thermographic maps because of the coarse 16 x 16 matrix of the classical CSI sequence. Therefore, at present the water PRF method appears to be most suitable for MR monitoring of small temperature changes during hyperthermia treatment.

Body Temperature↗

Performance and use of current sheet antennae for RF-hyperthermia of a phantom monitored by 3 tesla MR-thermography.

Several MR-compatible current sheet antennae (CSA) of different height (h) (16 cm (l) x 8 cm (w) x 1-5 cm (h)) were built for simulated RF (96 MHz) hyperthermia of a medium-sized (12l) tissue-equivalent phantom inside a 3 tesla whole body tomograph. Prior to use, efficiencies of the CSA were determined by network analysis and by calorimetry. Depending on the height h of the CSA and on the thickness d(bolus) of the water bolus used for RF-coupling of the CSA to the lossy medium, their efficiency varied between 20-70% and the CSA with h = 3 cm was selected for simulated RF hyperthermia. During heating, spatial temperature distributions (20-42 degrees C) of five slices (voxel size 2 x 2 x 10mm(3)) were recorded intermittently within 4 s/slice by measuring the temperature dependent shift of the (1)H resonance frequency (125.32 MHz). A phased array consisting of two identical CSA produced distinctly different spatial temperature distributions at 0 and 180 degrees phase difference between both RF channels feeding the antennae. Within a one-dimensional heat diffusion model, the specific absorption rate (SAR) of the electromagnetic wave generated by a single antenna was deduced from the experimental data resulting in a penetration depth (1/e(2)) of approximately 4 cm.