Publications and source records attributed to R P Salathé.

13 recordsLinked to original sources

Spatially incoherent illumination as a mechanism for cross-talk suppression in wide-field optical coherence tomography.

Comparison of two illumination modes for wide-field optical coherence tomography has revealed that spatially coherent illumination generates coherent cross talk, causing significant image degradation, and that spatially incoherent illumination, with an adequate interferometer design, provides an efficient mechanism for suppression of coherent cross talk. This is shown by comparison of a pulsed laser with a thermal light source for a U.S. Air Force resolution target covered with a scattering solution made from microbeads as well as for an ex vivo tooth.

Artifacts↗

Self-referenced method for optical path difference calibration in low-coherence interferometry.

A simple method for the calibration of optical path difference modulation in low-coherence interferometry is presented. Spectrally filtering a part of the detected interference signal results in a high-coherence signal that encodes the scan imperfections and permits their correction. The method is self-referenced in the sense that no secondary high-coherence light source is necessary. Using a spectrometer setup for spectral filtering allows for flexibility in both the choice of calibration wavelength and the maximum scan range. To demonstrate the method's usefulness, it is combined with a recently published digital spectral shaping technique to measure the thickness of a pellicle beam splitter with a white-light source.

Calibration↗

High-speed femtosecond pump-probe spectroscopy with a smart pixel detector array.

A new femtosecond pump-probe spectroscopy technique is demonstrated that permits the high-speed, parallel acquisition of pump-probe measurements at multiple wavelengths. This is made possible by use of a novel, two-dimensional smart pixel detector array that performs amplitude demodulation in real time on each pixel. This detector array can not only achieve sensitivities comparable with lock-in amplification but also simultaneously performs demodulation of probe transmission signals at multiple wavelengths, thus permitting rapid time- and wavelength-resolved femtosecond pump-probe spectroscopy. Measurements on a thin sample of bulk GaAs are performed across 58 simultaneous wavelengths. Differential probe transmission changes as small as approximately 2 x 10(-4) can be measured over a 5-ps delay scan in only approximately 3 min. This technology can be applied to a wide range of pump-probe measurements in condensed matter, chemistry, and biology.

Journal Article↗

Local coupling-coefficient characterization in fiber Bragg gratings.

We propose a new method for characterizing the local parameters of fiber Bragg gratings. This method combines measurement of the complex impulse response by optical low-coherence reflectometry and reconstruction of the complex coupling coefficient by layer peeling. Application of the method to a nonhomogeneous grating shows that the local coupling coefficient can be precisely determined with an axial resolution below 20 microm and a maximum error of less than 5% for amplitude and phase, respectively.

Journal Article↗

[Measuring corneal thickness in photo-keratectomy with a reflectometry incorporated into the laser beam of the excimer laser].

PURPOSE: To integrate a newly developed OLCR instrument into the optical system of the excimer laser. The instrument is designed to perform corneal pachymetry before, during, and after corneal photoablation and thus allow for a precise and continuous on-line measurement of the corneal photoablation process. METHODS: The conditions required to integrate the OLCR instrument into the excimer laser optics were investigated. With a technical setting providing on-line data of corneal thickness, three groups of 8-10 corneae received central keratectomies of 27 (group 1), 82 (group 2) and 163 (group 3) microns calculated central depth and 7.38 mm diameter. All measurements were performed with OLCR and ultrasound. RESULTS: The OLCR instrument was coupled into the optical system of the excimer laser and a useful signal obtained at SLD power levels of 40 microW incident on the cornea. Individual corneal thickness measurements were obtained before, during and after the photoablation procedure. In group 1, the ablation was 50.3 (40-68) microns measured with ultrasound and 30.2 (27-38) microns measured with OLCR. In group 2, the ablation was 101.1 (80-113) microns measured with ultrasound and 93.3 (76-109) microns measured with OLCR. In group 3, the ablation was 210.6 (190-227) microns measured with ultrasound and 188.4 (181-197) microns measured with OLCR. The precision (standard deviation) for measurements of individual corneas was 1-2 microns with OLCR and up to 12 mm in Ultrasound measurements. CONCLUSION: With this interferometric method, continuous, non-contact measurement of corneal thickness before, during and after excimer laser photoablation were performed. By establishing a feed-back control between the pachymetric measurements and the photoablation process, the precision of excimer ablation may possibly be further increased.

Animals↗

Non-contact microdrilling of mouse zona pellucida with an objective-delivered 1.48-microns diode laser.

BACKGROUND AND OBJECTIVE: A non-touch laser-induced microdrilling procedure is studied on mouse zona pellucida (ZP). STUDY DESIGN/MATERIALS AND METHODS: A 1.48-microns diode laser beam is focused in a 8-microns spot through a 45x objective of an inverted microscope. Mouse zygotes, suspended in a culture medium, are microdrilled by exposing their ZP to a short laser irradiation and allowed to develop in vitro. RESULTS: Various sharp-edged holes can be generated in the ZP with a single laser irradiation. Sizes can be varied by changing irradiation time (3-100 ms) or laser power (22-55 mW). Drilled zygotes present no signs of thermal damage under light and scanning electron microscopy and develop as expected in vitro, except for a distinct eight-shaped hatching behavior. CONCLUSION: The microdrilling procedure can generate standardized holes in mouse ZP, without any visible side effects. The hole formation can be explained by a local photothermolysis of the protein matrix.

Animals↗

Interstitial diode laser hyperthermia in the treatment of subcutaneous tumor.

BACKGROUND AND OBJECTIVE: Interstitial Laser Hyperthermia (ILH) has been investigated since the early 80s in the treatment of deep seated tumors. The purpose of this study was to evaluate the efficiency of diode ILH (830 nm) in a subcutaneous tumor model. STUDY DESIGN/MATERIALS AND METHOD: The antitumoral effect of diode ILH was assessed in a randomized study performed on 80 Swiss nu/nu mice. The tumor model was a subcutaneously implanted HT29 colonic carcinoma. The animals were assigned to four groups of 20 mice: Groups 1 and 3 were treated by ILH, groups 2 and 4 were not treated (control groups). Tumors were removed on day 3 in groups 1 and 2, and on day 30 in groups 3 and 4. The treatment was performed on tumors of 8 mm in diameter and a volume of 140 mm3. A laser irradiation of 360 J (power: 0.2 W; irradiation time: 1800 s) was delivered through a 300 microns optical fiber implanted in the tumor. The laser parameters insured temperatures of 46 degrees C in the central part of the tumor and 42 degrees C at the periphery. Tumor features were evaluated on day 3 and day 30. RESULTS: Untreated tumors grew rapidly up to a mean volume of 241 mm3 on day 3 (group 2) and 2,000 mm3 on day 30 (group 4). Treated tumors regressed to a mean volume of 32 mm3 on day 3 (group 1). On day 30, 40% of the tumors had totally disappeared and 60% showed partial response with small and peripheral residual tumor of 172 mm3 on an average, as to say 11.2 times smaller than in group 4. CONCLUSION: ILH with a low power 830 nm diode laser is an efficient treatment of subcutaneous tumor model. Partial responses are attributed to an insufficient heating at the tumor periphery. More precise control of the peripheral tumor temperature will improve the ILH results.

Animals↗

High-precision, high-speed measurement of excimer laser keratectomies with a new optical pachymeter.

In excimer-laser photorefractive keratectomy (PRK) the depth of the stromal tissue ablation is calculated from calibration and empirical data but is not actually measured, since a noncontact high-precision instrument for the measurement of the actual ablation has not been available. With a newly developed method for optical pachymetry we studied the depth of corneal ablations performed with an excimer laser. The excimer laser (Schwind Keratom) was calibrated according to the manufacturers' instructions. On freshly enucleated pig eyes, planokeratectomies with a diameter of 5 mm and a planned depth of 20, 40, 80, 160, and 320 microns were performed. With a newly developed high-precision, high-speed reflectometer the corneal thickness was measured immediately before and after the keratectomy. All ablations were deeper than expected. For a planned keratectomy of 20 microns we found a mean ablation depth of 29 microns; for 40 microns, a mean depth of 51 microns; for 80 microns, a mean depth of 100 microns; for 160 microns, a mean depth of 200 microns; and for 320 microns, a mean depth of 396 microns. The differences between mean and maximal ablation values were 58.6% at the 20-micron setting, 40.9% at the 40-micron setting, 20.1% at the 80-micron setting, 11.5% at the 160-micron and 9.8% at the 320-micron setting. Ablation rates showed the highest degree of variation in the 20-micron ablation group. Absolute variations in the ablation depth increased with ablation depth. In photorefractive procedures the volume of the tissue ablated is calculated from the instrument calibration but is not actually measured. Although the greater than expected ablation depths may in part be explained by differences between human and porcine tissue, the high degree of variability in the laser ablations may have other causes. We suggest that variations in the postoperative refractive results of PRK, which are currently attributed to variations in corneal would healing, may in part be due to variations in ablation depth.

Animals↗

Fragmentation process of current laser lithotriptors.

BACKGROUND AND OBJECTIVE: Flashlamp pumped dye (FPDL), Q-switched Nd:YAG, and alexandrite lasers are the most clinically used laser lithotriptors. Although calculi are fragmented by laser induced mechanical stresses for all lithotriptors, different fragment sizes and fragmentation efficiencies have been reported. In this work the effect of the pulse duration and pulse shape on the fragmentation processes is studied. MATERIAL AND METHODS: Fragmentation processes are characterized on model stones and on sensing target fibers. Stone fragmentation and cavitation bubble generation are observed by video flash photography. Shock wave occurrence and strength are monitored with an hydrophone. RESULTS: For the FPDL, stone fragmentation is induced by the collapse of the large cavitation bubble formed. For the Q-switched Nd:YAG, fragmentation is already observed during the laser pulse, at the plasma onset, although further fragmentation can occur at the bubble collapse. For pulse durations corresponding to the alexandrite, an intermediate fragmentation regime is observed. CONCLUSION: For the first time the physical basis of the observed differences in the fragmentation efficiencies of current laser lithotriptors is described. For nanosecond durations the fragmentation processes are governed by plasma induced shock waves. On the contrary, for microsecond durations fragmentation is governed by cavitation. The high fragmentation efficiency of microsecond lasers is due to a high laser energy transfer into cavitation.

In Vitro Techniques↗

Scanning electron microscopy of microarterial anastomoses with a diode laser: comparison with conventional manual suture.

A diode-laser (830 nm)-assisted carotid artery end-to-end microanastomosis (LAMA) and a contralateral manual suture anastomosis (CMA) were performed in 70 Wistar rats. The vessel sealing was performed on the left carotid by laser pulses (average 3) of 500 mW power and 4.5 sec exposure time, the beam being focused on a spot of 300 microns diameter (700 W/cm2). The CMA was achieved on the right carotid by six 10-0 stitches. From day 0 to day 210, 40 specimens underwent scanning electron microscopy. The laser impact produced a wall injury of 100 microns in width, with an immediate sealing effect due to protein denaturation and collagen fusion of media and adventitia. The anastomosis became re-endothelialized by day 3, while the longitudinal arrangement of the endothelial cells was restored from day 10 on. In the long term, a thick collagenous meshwork of collagen and elastic fibers maintained the strength of the media, while normal endothelium covered the anastomosis. Inversely, after CMA vessel repair was delayed, and the anastomotic line was more irregular and underlined by medial fibrotic scar. In both anastomoses, the patency rate was 93 percent, with nonlethal complications. The advantages of LAMA vs. CMA were: shorter operating time (13 min/22 min), reduced intraoperative trauma, better healing of endothelium, and a miniaturization of the laser source well adapted to microsurgery.

Anastomosis, Surgical↗

Temperature dependence of reflectance and transmittance of the artery exposed to air during laser irradiation.

Reflectance, transmittance, and temperature of the arterial wall exposed to air are measured during laser irradiation for different heating dynamics. Temperature dependence of the reflectance and transmittance is then deduced. Our results show a competing effect between temperature and dehydration, resulting in a distinct minimum of transmittance and maximum of reflectance. As a consequence, a direct correlation of reflectance and transmittance with temperature is only possible for a specific dynamics.

Animals↗

Continuous non-contact corneal pachymetry with a high speed reflectometer.

PURPOSE: We developed an instrument that permits non-contact, continuous, high speed and high precision monitoring of corneal thickness and tested the stability and reproducibility of measurements made over extended time periods and under various conditions of low surface reflectivity encountered during protracted exposure of the unmoistened corneal surface to ambient air. METHODS: The optical pachymeter (basic component of a broad-band, all-fiber Michelson interferometer) was used to monitor changes in the central corneal thickness of enucleated porcine eyes. Measurements were performed on three groups of eight eyes, each with different surface characteristics: intact epithelium, mechanically abraded epithelium, and 90 microm excimer laser keratectomy. Corneal thickness was monitored continuously with values recorded every 2 to 3 minutes for periods up to 1 hour in the absence of surface rinsing. RESULTS: The thicknesses of all unmoistened corneas could be monitored with a precision of 1 microm (ascertained using a calibration glass plate and a living human cornea) over the entire observation period. Under ambient air conditions, deturgescence occurred in each case, and ranged from 1 to 5 microm/min. The rate of corneal thinning was fairly constant during the first 15 minutes of monitoring, but was nonlinear thereafter. Corneas with an intact epithelium had the lowest thinning rate with only 10% of the original thickness lost during the course of 1 hour. Deturgescence increased to 25% in corneas that had mechanical removal of the epithelium and to 28.5% in those that had an anterior excimer laser keratectomy, during a similar time-period. CONCLUSION: With this new interferometric method, continuous, non-contact measurement of corneal thickness is possible to within a precision of 1 microm for periods up to 1 hour, even under the modified surface conditions after photoablative keratectomy. This device may be useful for on-line monitoring of ablation depths during such procedures.

Animals↗

[Vascular microanastomosis with diode laser. Control study and morphological results].

Direct diode laser carotid (0.7-1.2 mm) end-to-end microanastomosis versus contro-lateral manual suture microanastomosis (CMA) were performed in 70 Wistar rats. The laser beam-wavelength 830 nm- was transmitted through a micromanipulator and provided a focused spot of 300 microns in diameter. After placement of three 10.0 Ethilon stitches for edge coaptation, the laser anastomosis was performed using laser shots (average 3) of 500 mW power, 4.5 s duration and 700 W/cm2 irradiance each. CMA was performed by six 10.0 stitches. Good vascular flow was confirmed by macroscopic controls, Doppler spectral analysis (n = 548) and digitalized angiography (n = 18) performed from day 0 to day 210. The patency rate (93%) as well as the complication rate (5/66) were similar in both series. Nevertheless light and scanning electron microscopy (n = 82) showed the morphological superiority of laser anastomosis: reendothelialization by day 3 and medial collagen restructuration by day 10 whilst after CMA, the arterial wall repair was delayed and the medial scar occupied by fibrotic tissue. The other advantages of the laser anastomosis were, shorter operating time minimizing organ ischemia (13 min versus 22 min), and slight endothelial trauma reducing thrombogenic risk. The technical advantages of diode laser were pointed out: miniaturization, no special maintenance and decreasing price of diodes.

Anastomosis, Surgical↗