Self-referenced method for optical path difference calibration in low-coherence interferometry.

Abstract

A simple method for the calibration of optical path difference modulation in low-coherence interferometry is presented. Spectrally filtering a part of the detected interference signal results in a high-coherence signal that encodes the scan imperfections and permits their correction. The method is self-referenced in the sense that no secondary high-coherence light source is necessary. Using a spectrometer setup for spectral filtering allows for flexibility in both the choice of calibration wavelength and the maximum scan range. To demonstrate the method's usefulness, it is combined with a recently published digital spectral shaping technique to measure the thickness of a pellicle beam splitter with a white-light source.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Laubscher, L Froehly, B Karamata, R P Salathé, T Lasser. 2003-12-15. Self-referenced method for optical path difference calibration in low-coherence interferometry.. https://doi.org/10.1364/ol.28.002476

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of the electrolyte concentration on cation binding in aqueous surfactant solutions.

Electrospray ionisation mass spectrometry (ESI-MS) is used for the qualitative and quantitative study of ion binding to interfaces. The ESI-MS measurements are carried out in aqueous solutions of sodium dodecyl sulphate (SDS) in the presence of NaCl, NH(4)ClO(4) , KCl, or Mg(ClO(4))(2) . The effect of the electrolyte concentration on the fractions, y(cation(+) ), of the DS(-) monomers bound to the cations is shown. Moreover, the binding stability of different cations with DS(-) monomers is determined versus the electrolyte concentration. This stability and the y(Na(+) ) values (the Na(+) ions derived from SDS), estimated in the presence of a given electrolyte, are quantitatively correlated with the electrolyte cation effect on the water structure. We also present calibration curves from which the molar concentrations of the sodium ions (derived from SDS) and of the other cations (derived from the electrolyte), bound to the SDS-micelle surface at a given electrolyte concentration, can be obtained. Besides, specific ion effects (Hofmeister effects) are considered for 1:1 electrolytes.

Calibration↗

Strategies for data collection and calibration with a pinhole-geometry SAXS instrument on a synchrotron beamline.

Undulator X-ray sources on third-generation synchrotrons have pushed small-angle X-ray scattering (SAXS) to the forefront of techniques in nanoscience and technology. With higher X-ray fluxes and improved focusing, it is usually the scattered intensity detector that places the most serious limitations on the overall capabilities of the instrument. Incorporating relatively simple components like point detectors, scattering standards, masking filters and in-line sample visualization into the flight tube of a pinhole-geometry SAXS camera can do much to mitigate these limitations. How these enhancements can be incorporated into routine data collection is demonstrated on the ChemMatCARS SAXS instrument, which utilizes pinhole geometry with an undulator insertion device at sector 15 of the Advanced Photon Source. In addition, with an X-ray energy range of 6-32 keV (2.0-0.4 A) and an energy resolution of 10(-4) DeltaE/E, this instrument can measure anomalous SAXS over a wide variety of atom species, with reliable normalization of scattered data.

Calibration↗

Non-diverging analytic expression for the on-axis sensitivity of converging collimators: experimental verification.

The previous paper presented the derivation of an analytical formula for the sensitivity of converging collimators that does not diverge at the focal locus of the collimator. Its predictions, those from a simplified version, and those from the most commonly referenced formula are compared to Monte Carlo and experimental data. Agreement is excellent for all formulae far from the focal locus of the collimator, where it is markedly better for the new formula and its approximation. It is inferred that such formulae should be used in the cases identified by theory, namely around the focal locus of collimators of any focal length and over a substantial part of the field-of-view for short focal length collimators.

Calibration↗