Acute evaluation of a preformed single-pass VDD/DDD pacing lead.

The clinical utility of single lead, atrial synchronous, ventricular pacing (VDD), for patients with normal sinus function and heart block is well established. Atrial stimulation, unavailable in VDD systems presents a significant disadvantage. DDD pacing systems however, require the introduction and positioning of two separate leads. The acute human study discussed evaluated a modified version of a commercially available VDD lead with a preshaped lobe, capable of both sensing and pacing the right atrium. "P" waves and atrial stimulation thresholds were determined in five patients. The mean P-wave was 2.5 +/- 1 millivolts. Atrial stimulation in the unipolar configuration was 1.6 +/- 0.5 volts and 1.7 +/- 0.9 volts in the bipolar configuration. These acute stimulation thresholds and sensing amplitudes were comparable to conventional DDD pacing systems. Therefore, single-lead DDD pacing may be feasible and warrants further study.

Cardiac Pacing, Artificial↗

Toward optimizing a preshaped catheter and system parameters to achieve single lead DDD pacing.

P wave electrogram amplitudes and atrial stimulation thresholds were determined in eight Hanford miniature swine using a preshaped catheter with an "S" curve in the SVC, and a major lobe in the atrium to enhance electrode contact with the atrial wall. The catheter was designed for pacing and sensing in the DDD mode. P wave amplitudes were also ascertained with two commercially available VDD leads and compared to the data from the experimental catheters. The preshaped catheter used two 6-mm2 platinum iridium atrial electrodes with a 7-mm separation. Both atrial electrodes are on the same side of the catheter, facing outward on the major atrial lobe formed in the catheter. The P wave amplitudes were tested only in the differential bipolar configuration. For the eight preshaped catheters, the mean was 6.6 +/- 3.8 mV while for the conventional leads it was 2.9 +/- 1.6 mV. The mean atrial stimulation thresholds ranged from 1.1 +/- 0.2 V to 2.3 +/- 1.2 V, with still lower thresholds of 0.9-1.3 V when using the parallel unipolar atrial electrode configuration, in which both parts of the bipolar atrial electrode are configured as a unipolar electrode. The data suggest that bipolar simulation may be effective if sequential reverse polarity pulses are used to achieve cathodal stimulation from each electrode of the bipolar pair, on a beat-to-beat basis.

Animals↗

Toward optimizing the detection of atrial depolarization with floating bipolar electrodes.

Some concepts derived from modern literature on the physics of cardiac muscle conduction regarding optimization of the design of electrode systems for detection of atrial depolarization and a preliminary clinical corroboration of the concepts are presented. The concepts of most import are 1) that the mechanical dimensions of sensing electrodes in all planes have to be as small as possible relative to the dimensions of the extracellular waveform dimensions associated with depolarization action potentials, and 2) that the distance between bipolar electrodes should be tuned to be greater than the dimensions of the extracellular waveform to avoid subtractive interference patterns associated with saltatory propagation in aging cardiac muscle. Additionally, in the practical application of chronic atrial sensing from a single lead for use in an implanted VDD pacing system, it is also important to consider electrode size and its effect on impedance level.

Cardiac Pacing, Artificial↗

Utility of the atrial endocardial electrogram concurrent with dual-chamber pacing in the determination of a pacemaker-mediated arrhythmia.

A 73-year-old male required a permanent pacemaker for complete heart block. After placement of the dual-chamber pacemaker, the patient developed random, repetitive ventricularly paced coupling at the upper rate limit. The diagnosis made from the surface electrocardiography was one of ventricular tracking of occult (T wave obscured) atrial ectopic activity. Examination of the telemetered atrial electrogram (EGM) revealed a diagnosis of intermittent far-field atrial sensing of the terminal ventricular depolarization. The value of obtaining an atrial electrogram during dual-chamber pacing is discussed.

Aged↗

Report of the NASPE Mode Code Committee.

The NASPE Mode Code Committee was formed in response to the growing need for efficient means of describing the function of increasingly complex single- and dual-chamber cardiac pacemakers. After considering numeric, alphabetic, and pictorial codes, the Committee recommended the adoption of two codes: a generic code which is similar to the Revised ICHD Code and is suitable for conversational use, and a specific code, based on one developed by Brownlee and others, that permits more detailed specification of both antibradycardia and antitachycardia functions. The specific code described in this report was adopted by the NASPE Executive Advisory Committee as the NASPE Specific Code in March, 1983. The generic code was not adopted but is described herein for future reference in the light of experience to be gained in the use of the recently published Revised ICHD Code.

Pacemaker, Artificial↗

Simultaneous atrial and ventricular electrogram transmission via a specialized single lead system.

No telemetrically monitorable pacemakers are capable of detecting and transmitting the complete electrogram (EGM) during normal and paced rhythms, although some are capable of detecting and transmitting either the P- or R-wave. A new lead and telemetry-pacemaker system has been developed that permits the transmission of the complete EGM and is not adversely affected by pacemaker outputs or after-potentials. Electrodes are placed in the right ventricle and atrium to optimize EGM detection. These A-V data probe electrodes are electrically separate from the pacing-sensing electrodes but are structurally part of a coaxial ventricular lead that is no larger than a conventional bipolar lead (2.3 mm). The telemetry system is also compatible with telephone monitoring systems. The system has consistently demonstrated its ability to detect accurately the EGM during normal sinus rhythms and does not affect atrial, ventricular, or A-V sequential pacing. In addition, this system can detect and transmit EGM abnormalities, including ectopic beats, retrograde conduction, and ischemic changes. A-V data leads with telemetry monitored VVI pacemakers have been implanted in dogs for over two years. This system will provide the means to detect and telemetrically record noninvasively the entire normal and abnormal EGM, even in pacer dependent patients. (PACE, Vol. 7, November-December, 1984).

Animals↗

A new atrial lead with improved stability and P-wave detection.

A new segmented polyether polyurethane atrial pacemaker lead has been developed and tested acutely and chronically in dogs. This lead was constructed so that its tip could quickly and accurately be positioned in close proximity to the S-A node and provide long-term stability without the use of active fixation devices such as tines or screws. The acute intrinsic P-wave potentials seen at the S-A node area (9.7 +/- 4.7 mV) were superior to those detected in the appendage (4.7 +/- 2.8 mV) and coronary sinus (6.8 +/- 4.1 mV). There were no significant differences in pacing thresholds between sites. In long-term studies, transvenous (jugular) leads maintained their position for over three months without dislodgment in active unrestrained dogs with only a 25% decrease in intrinsic P-wave potentials. The chronic pacing thresholds for this lead were similar, or superior, to those reported for other pacemaker lead placement sites. The polyurethane coating material produces no adverse tissue reaction or thrombosis.

Animals↗

A new symbolic language for diagramming pacemaker/heart interaction.

A new symbolic language is presented that can be used to diagram pacemaker/heart interactions. The language symbolically indicates "normally" conducted and ectopic events; pacemaker stimuli; pacemaker capture of the chamber; triggered pacemaker stimuli by "normal" or ectopic events; as well as such anomalous pacemaker/heart interactions as failure to sense; "crosstalk" between electrodes; and "normal," ectopic, or paced events in one chamber sensed by the electrode in the other chamber. In addition, symbols are provided to represent antegrade and retrograde accessory pathway conduction, and electronic and physiological refractory intervals. A common baseline is used to separate symbols for atrial activity, above the baseline, from those for ventricular activity, below the baseline. Parallel baselines are used to plot refractory intervals. Thus, even complex dual-chamber pacemaker operating modes can be represented with intrinsic and stimulated cardiac response to pacemaker operation. The language can be sketched out informally for description of general concepts or drafted on millimeter grid paper to make precise timing notations. It is especially useful for interdisciplinary communication of ideas about complex pacemaker/heart interactions.

Atrial Function↗

A new code for pacemaker operating modes.

A new code is proposed that can be used as a supplement to th ICHD code to describe single- and dual-chamber pacemaker operating modes. The code visually indicates the chamber(s) involved by means of a common base-line with indicators for atrial activity above and ventricular activity below. Letter indicators are used. For single-chamber units, an O represents the chamber in which no pacemaker activity occurs. P represents pacing, S sensing, IA inhibition by a sensed atrial event, IV inhibition by a sensed ventricular event, TA triggering by a sensed atrial event, and TV triggering by a sensed ventricular event. For example, a pacemaker mode described as PSIAIV/PSTAIV paces and senses both chambers; inhibits atrial pacing by a sensed event in either chamber; inhibits ventricular pacing by a sensed ventricular event but triggers ventricular pacing, after an assumed A-V delay, by a sensed atrial event. Thus even the most complex modes of pacing operation can be clearly and accurately described by means of this new code. Especially useful in teaching applications is the distinction of activity by chamber and the description of response in one chamber to activity in the other.

Heart↗

The effects of electrode position on the detection of the transvenous cardiac electrogram.

Adequate sensing of the cardiac electrogram is a necessary requisite for all demand cardiac pacemakers. In order to define better the effects of position of the sensing electrode on the ability of the pacer to detect the electrogram, a specially designed lead system with a movable, large surface area (50 mm2) proximal ring electrode and a small surface area distal tip electrode was placed transvenously in 12 mongrel dogs. As the sensing electrode was moved away from the right ventricular apex, there were slight but insignificant decreases in R wave amplitude. When the electrode was moved retrograde through the tricuspid valve into the atria there was a marked decrease in R wave sensing; however, this was accompanied by a significant increase in P wave amplitude. Therefore, with a large surface area electrode, direct contact with the myocardium is not needed for the detection of adequate P and R waves. In addition, a pacer lead system utilizing this sliding sensing electrode design could be used to optimize sensing position, either for atrial or ventricular sensing pacemakers.

Animals↗

Myocardial stimulation impedance: the effects of electrode, physiological, and stimulus variables.

With exposed metal at the electrode tissue interface (8 mm2, 28 mm2, 57 mm2), myocardial threshold stimulation impedance increased as pulse duration was lengthened, with left ventricular intramyocardial stimulation, and with the smaller surface area electrode. An 0.5 mm2 differential-current-density electrode, which eliminated direct metal-to-tissue contact at the electrode-myocardial interface, was associated with notably higher impedances than each of the three metal tip electrodes and did not show increasing impedance levels with changes in pulse duration, confirming the minimization of polarization energy losses with this device. The majority of electrode, electrode tissue interface, and myocardial variables that are characterized by high threshold stimulation impedance are associated with low threshold energy requirements for pacing and reduced pacemaker power source drain. No accurate information about sensing impedances can be derived from current knowledge of pacing impedance.

Acid-Base Imbalance↗

Current status of pacemaker power sources.

After years during which pacers of very similar design and capabilities were provided by a small number of manufactures, many different lithium, halogen, rechargeable, and nuclear power sources are now available. The variety of chemistries, methods of construction, and sealing techniques used in the batteries of the different manufacturers is almost unlimited. This has made it necessary for physicians who implant and follow pacer to acquire a general knowledge of the field if they are to make an informed choice of pacemaker power source for implantation and if they are to manage recalls with a minimum of patient and physician trauma. More experience is required before it can be definitely determined which of the new pacer power sources will prove superior, but when coupled with well-designed, hermetically sealed pulse generators, all are capable of providing continuous pacing for at least 5 years and the 10-year pacemaker is now a probability.

Animals↗