PubMed HealthSearch

PubMed · 6167957

A new code for pacemaker operating modes.

Abstract

A new code is proposed that can be used as a supplement to th ICHD code to describe single- and dual-chamber pacemaker operating modes. The code visually indicates the chamber(s) involved by means of a common base-line with indicators for atrial activity above and ventricular activity below. Letter indicators are used. For single-chamber units, an O represents the chamber in which no pacemaker activity occurs. P represents pacing, S sensing, IA inhibition by a sensed atrial event, IV inhibition by a sensed ventricular event, TA triggering by a sensed atrial event, and TV triggering by a sensed ventricular event. For example, a pacemaker mode described as PSIAIV/PSTAIV paces and senses both chambers; inhibits atrial pacing by a sensed event in either chamber; inhibits ventricular pacing by a sensed ventricular event but triggers ventricular pacing, after an assumed A-V delay, by a sensed atrial event. Thus even the most complex modes of pacing operation can be clearly and accurately described by means of this new code. Especially useful in teaching applications is the distinction of activity by chamber and the description of response in one chamber to activity in the other.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R R Brownlee, J B Shimmel, C J Del Marco. 1981. A new code for pacemaker operating modes.. https://doi.org/10.1111/j.1540-8159.1981.tb03718.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Evaluation and documentation of tomographic images and further data using the Apple-Macintosh PC].

Use of the personal microcomputer for the analysis of clinical cardial PET studies acquired at the Paul Scherrer Institute in Villigen, Switzerland. At present this is the only PET facility in Switzerland. As the local computers were not usually available for image analysis, it was necessary to find a convenient way to visualize and analyze the PET images in our department in the Cantonal Hospital, Aarau (distance to Villigen some 30 km). The personal microcomputer is, as other authors have already shown, in fact capable of handling the acquired images (128 by 128 pixels) easily. We use a Macintosh IIcx (16 MHz Motorola 68030 CPU) as image analysis workstation. In spring 1990 we implemented a software which could read the original Siemens matrix file directly into the Macintosh PC. As the handling of this software was somewhat clumsy, we now use a very powerful software ("Explorer", UCLA), which is specially designed for PET analysis. Analysis of PET data on the personal computer saves both time and money as we are able to use a standard PC periphery, which is less expensive than specially designed medical units.

Heart