PubMed Health⌕ Search

Biomedical subjects

R Rayman

Publications and source records attributed to R Rayman.

9 recordsLinked to original sources

Cumulative sum failure analysis of a policy change from on-pump to off-pump coronary artery bypass grafting.

BACKGROUND: Use of the sequential probability cumulative sum (CUSUM) technique may be more sensitive than standard statistical analyses in detecting a cluster of surgical failures. We applied CUSUM methods to evaluate the learning curve after a policy change by a single surgeon from routine on-pump (cardiopulmonary bypass [CPB]) to off-pump coronary artery bypass grafting (OPCAB). METHODS: Fifty-five consecutive first-time coronary artery bypass patients (CPB group) were compared with the next 55 patients undergoing an attempt at routine OPCAB using the same coronary stabilizer. The goal in OPCAB patients was to obtain complete revascularization, albeit with a low threshold for conversion to CPB to maximize patient safety during the learning curve. Preoperative patient risk was calculated using previously validated models of the Cardiac Care Network of Ontario. The occurrence of operative mortality and nine predefined major complications (myocardial infarction, bleeding, stroke, renal failure, balloon pump use, mediastinitis, respiratory failure, life-threatening arrhythmia, and sepsis) was compared between the CPB and OPCAB groups using Wilcoxon, Fisher exact, and two-tailed t tests, as well as CUSUM methodology. An intention to treat analysis was performed. RESULTS: The CPB and OPCAB groups had similar predicted mortality and length of stays (2.2% +/- 2.5%, 8.1 +/- 2.5 days versus 2.4% +/- 3.5%, 8.1 +/- 2.4 days, respectively). The mean number of grafts per patient was 3.1 +/- 0.7 in the CPB group versus 3.0 +/- 0.7 in the OPCAB group (p = 0.45). Two of 55 (3.6%) CPB patients died, as opposed to 1 of 55 (1.8%) OPCAB patients (p = 0.99). Eight of 55 CPB patients (14.5%) incurred major complications, as opposed to 4 of 55 (7.3%) OPCAB patients (p = 0.36). Median hospital length of stay was 6.0 days in the CPB group versus 5.0 days in the OPCAB group (p = 0.28). On CUSUM analysis, the failure curve in CPB patients approached the upper 80% alert line after eight cases, whereas the curve in OPCAB patients reached below the lower 80% (reassurance) boundary 28 cases after the policy change, indicating superior results in the OPCAB group despite the learning curve. CONCLUSIONS: A policy change from coronary artery bypass on CPB to routinely attempting OPCAB can be accomplished safely despite the learning curve. CUSUM analysis was more sensitive than standard statistical methods in detecting a cluster of surgical failures and successes.

Cardiopulmonary Bypass↗

RAVECAB: improving outcome in off-pump minimal access surgery with robotic assistance and video enhancement.

OBJECTIVE: To determine the efficacy of using the harmonic scalpel and robotic assistance to facilitate thoracoscopic harvest of the internal thoracic artery (ITA). DESIGN: A case series. SETTING: London Health Sciences Centre, University of Western Ontario, London, Ont. PATIENTS AND METHODS: Fifteen consecutive patients requiring harvest of the ITA for coronary artery bypass grafting. INTERVENTION: Robot-assisted, video-enhanced coronary artery bypass (RAVECAB) through limited-access incisions, using the harmonic scalpel and a voice-activated robotic assistant. MAIN OUTCOME MEASURES: Ease and duration of the harvesting technique, complications of the procedure, graft flow and patency, and duration of postoperative hospitalization. RESULTS: RAVECAB facilitated thoracoscopic dissection of the ITA with the harmonic scalpel in all cases. There were no conversions to a standard approach and no reoperations for bleeding. The mean (and standard deviation) ITA harvest time was 64.1 (22.9) minutes (range from 40 to 118 minutes). Robotic voice command capture rate was greater than 95%. Mean (and SD) intraoperative graft flows were 33.1 (26.8) mL/min (range from 14 to 126 mL/min). There was 100% graft patency on postoperative angiography. There were no deaths, perioperaive myocardial infarction or arrhythmias. Mean (and SD) postoperative hospitalization was 3.3 (0.8) days. CONCLUSIONS: RAVECAB is a demanding procedure that addresses many of the disadvantages of the "conventional" minimally invasive coronary artery bypass. It allows complete pedicle dissection with minimal ITA manipulation and assures sufficient conduit length and a tension-free coronary artery anastomosis. All anastomoses were performed under direct vision through a 5- to 8-cm inferior mammary incision.

Coronary Artery Bypass↗

[Clinical experience in thoracoscopic left internal mammary artery harvesting with voice activated robotic assistance].

Between September 1998 to February 2000, 45 consecutive patients underwent robotic-assisted, video-enhanced coronary artery bypass grafting. All IMA's were harvested using the voice-activated robotic assistant (AESOP 3000, Computer Motion Inc, Santa Barbara, CA) and the Harmonic scalpel (Ethicon Endo-Surgery, Cincinnati, OH). Left IMA's were successfully harvested in all patients. Harvested IMA's were anastomosed to LAD's under direct vision through limited left anterior thoracotomy. The IMA harvest time was 57.8 +/- 23.2 min, intraoperative graft flow was 34.3 +/- 20.5 ml/min, postoperative hospital stay was 3.9 +/- 1.5 days. The early postoperative angiogram showed that all grafts were patent. There was no mortality, no significant morbidity. The robotic assisted, video enhanced CABG provides safe and complete LIMA dissection with minimal manipulation and assures sufficient LITA length for tension free anastomosis.

Adult↗

A comparison of robot-assisted versus manually constructed endoscopic coronary anastomosis.

BACKGROUND: New technology has enabled surgeons to attempt totally endoscopic coronary artery bypass grafting. Our purpose was to compare three different techniques of totally endoscopic anastomosis using a porcine animal model. METHODS: Porcine hearts were excised and the right coronary artery was dissected free for use as an arterial graft. The hearts were placed in a human thoracic model and an endoscopic arterial anastomosis between the free right coronary artery and the left anterior descending coronary artery was performed using one of the following: (1) two-dimensional visualization with straight endoscopic instruments (n = 8); (2) three-dimensional head-mounted visualization with curved endoscopic instruments (n = 7); or (3) three-dimensional visualization with robotic telemanipulation (n = 8). Pathologic analysis of suture placement, vessel trauma, and patency was performed. Anastomoses were graded according to quality, ease, and patency using a seven-point Likert scale (1 = excellent, 7 = very poor). RESULTS: Endoscopic anastomotic ease and quality were significantly improved when three-dimensional visualization and curved endoscopic instruments were employed. Telemanipulation enhanced the process and provided the best operative results with regard to time required to construct the anastomosis, as well as ease and quality. CONCLUSIONS: Totally endoscopic anastomosis is feasible using currently available technology. Three-dimensional visualization and robotic telemanipulation significantly facilitate anastomosis construction and will likely benefit clinical operative outcome.

Anastomosis, Surgical↗

Robot-assisted computer enhanced closed-chest coronary surgery: preliminary experience using a Harmonic Scalpel and ZEUS.

BACKGROUND: Successful endoscopic harvesting of arterial conduits is critical to the performance of totally endoscopic bypass grafting. Recent success with computer-enhanced robotic systems in the performance of endoscopic single vessel coronary artery bypass (ENDOCAB) has paved the way for developing techniques for multivessel ENDOCAB. The Harmonic Scalpel (Ethicon Endo-Surgery, Cincinnati, OH) has previously demonstrated versatility and efficacy in manual endoscopic internal thoracic artery (ITA) harvesting. This study was undertaken to determine the feasibility of adapting this technology to a robotic telemanipulation system and its safety and efficacy in telerobotic ITA harvesting. METHODS: The Harmonic Scalpel was adapted to the ZEUS robotic surgical system (Computer Motion, Goleta, CA) and used to harvest the ITA in 19 patients undergoing multivessel off-pump coronary artery bypass (OPCAB) surgery. With the left lung collapsed, the ITA was harvested in all patients with CO2 insufflation through three 5 mm ports in the left chest. Postoperative angiography and transthoracic Doppler studies were performed in all patients. RESULTS: There were no ITA injuries and patients tolerated insufflation without hemodynamic compromise. Side branches were controlled easily without bleeding. Average ITA harvest time was 65 +/- 21 minutes. All vessels were patent after harvesting and demonstrated no angiographic evidence of injury. CONCLUSIONS: This paper demonstrates a technique by which the Harmonic Scalpel can be readily adapted to the ZEUS robotic telemanipulation system. Using this system, ITA's can be safely harvested totally endoscopically within a reasonable time frame for patients undergoing ENDOCAB.

Coronary Angiography↗

Assessing the safety of pediatric laparoscopic surgery.

We studied deviations from normal physiology in piglets (n = 10; average weight 5.75 kg) during carbon dioxide (CO2) pneumoperitoneum. Cardiopulmonary data were gathered during varying intraabdominal pressures (IAP = 8, 12, 15, 20 mm Hg), each sustained for 10 mins. Each animal was its own preinsufflation and exsufflation control. A rapid, significant rise in arterial CO2 pressure from preinsufflation (46.5 +/- 6.7 mm Hg) to insufflation at 20 mm Hg (72.9 +/- 15 mm Hg; p < 0.05) initiated further cardiac adjustments. Responses included a sustained increase in cardiac index (presufflation = 3.1 +/- 1.4; 20 mm Hg IAP = 3.6 +/- 1.2), increased heart rate (preinsufflation = 121 +/- 21; 20 mm Hg IAP = 150 +/- 28; p < 0.05), and left ventricular stroke work (20 mm IAP = 22.7 +/- 8.9; exsufflation 20 min = 15.3 +/- 9.4 g.m/m2; p < 0.05). There was a significant arterial-end CO2 tidal difference throughout insufflation, as great as 15 mm Hg (p < 0.05), suggesting increasing ventilation dead space. Core temperature decreased significantly from preinsufflation (35.3 +/- 1.3 degrees C) to 20 mm Hg IAP (33.6 +/- 1.5 degrees C, p < 0.05). We suggest the following guidelines based on the above data: (a) preoperative examination screening for cardiopulmonary abnormalities; (b) fluid replacement to normal hydration only; (c) cuffed endotracheal tubes for effective ventilation; (d) careful adjustment of minute ventilation to achieve normocapnia; (e) CO2 warming; (f) maximal insufflation pressure of 12 mm Hg; (g) postoperative care emphasizing respiratory and thermoregulation status.

Abdomen↗

Steady flow visualization in a rigid canine aortic cast.

Steady flow studies were conducted in a transparent canine aortic cast. The cast segment stretched from the aortic valve to beyond the renal arteries and included all major branches. Flow was visualized by analysis of dye streaklines. Flow rates for basal and exercising cardiovascular states were simulated. The Reynolds numbers in the ascending aorta for basal and exercising conditions were 900 and 1587 respectively. Aortic core flow was laminar in basal simulations. Disturbed flow commenced in the upper descending aorta with exercising flow rates. Separation zones existed along the inner curvature of the aortic arch and the proximal walls of the brachiocephalic, left subclavian, and coeliac arteries. Such zones may exist over a portion of the cardiac cycle. If either renal artery was occluded, then a vortex formed. This vortex is associated with high shear regions which correlate well with sites where sudanophilic lesions have been reported in cholesterol-fed nephrectomized rabbits.

Animals↗