Robot-assisted computer enhanced closed-chest coronary surgery: preliminary experience using a Harmonic Scalpel and ZEUS.

Abstract

BACKGROUND: Successful endoscopic harvesting of arterial conduits is critical to the performance of totally endoscopic bypass grafting. Recent success with computer-enhanced robotic systems in the performance of endoscopic single vessel coronary artery bypass (ENDOCAB) has paved the way for developing techniques for multivessel ENDOCAB. The Harmonic Scalpel (Ethicon Endo-Surgery, Cincinnati, OH) has previously demonstrated versatility and efficacy in manual endoscopic internal thoracic artery (ITA) harvesting. This study was undertaken to determine the feasibility of adapting this technology to a robotic telemanipulation system and its safety and efficacy in telerobotic ITA harvesting. METHODS: The Harmonic Scalpel was adapted to the ZEUS robotic surgical system (Computer Motion, Goleta, CA) and used to harvest the ITA in 19 patients undergoing multivessel off-pump coronary artery bypass (OPCAB) surgery. With the left lung collapsed, the ITA was harvested in all patients with CO2 insufflation through three 5 mm ports in the left chest. Postoperative angiography and transthoracic Doppler studies were performed in all patients. RESULTS: There were no ITA injuries and patients tolerated insufflation without hemodynamic compromise. Side branches were controlled easily without bleeding. Average ITA harvest time was 65 +/- 21 minutes. All vessels were patent after harvesting and demonstrated no angiographic evidence of injury. CONCLUSIONS: This paper demonstrates a technique by which the Harmonic Scalpel can be readily adapted to the ZEUS robotic telemanipulation system. Using this system, ITA's can be safely harvested totally endoscopically within a reasonable time frame for patients undergoing ENDOCAB.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Kiaii, W D Boyd, R Rayman, W B Dobkowski, S Ganapathy, G Jablonsky, R J Novick. 2000. Robot-assisted computer enhanced closed-chest coronary surgery: preliminary experience using a Harmonic Scalpel and ZEUS.. https://pubmed.ncbi.nlm.nih.gov/11074972/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Repeat right transradial percutaneous coronary intervention in a patient with dextrocardia: the right approach to the right-sided heart.

Dextrocardia (DC) is a rare cardiac condition in which the cardiac location, as well as apex, is rightwardly displaced. As the incidence of atherosclerotic disease is similar to that of the general population, there have been few reports of percutaneous coronary interventions (PCIs) in these patients. Proposed technical strategies for successful angiography and PCI in DC include counter-directional torquing of the catheter, as well as right-left mirror-image inversion angiographic views. All previous reports of DC PCIs have been via transfemoral access.We present a case of successful repeat transradial PCI in a patient with DC. This is first report of transradial coronary angiography, PCI, or repeat PCI in a DC patient. A literature review of technical considerations, including our own recommendations for guide catheter selection, are discussed. We also review the anatomic variations and epidemiology of DC. Although access complications for transradial PCI is known to be lower than that of the transfemoral approach, challenges in technique and concern of repeat access have limited the popularity of the former. Our report demonstrates the safety and feasibility of transradial angiography, PCI, and even repeat PCI, in the rare patient with DC.

Coronary Angiography↗