PubMed Health⌕ Search

Biomedical subjects

R Waksman

Publications and source records attributed to R Waksman.

At least 37 records · Page 2Linked to original sources

Serial intravascular ultrasound analysis of the impact of lesion length on the efficacy of intracoronary gamma-irradiation for preventing recurrent in-stent restenosis.

BACKGROUND: The relation between lesion length and effectiveness of brachytherapy is not well studied. METHODS AND RESULTS: We compared serial (postintervention and follow-up) intravascular ultrasound findings in 66 patients with native coronary artery in-stent restenosis (ISR) who were treated with (192)Ir (15 Gy delivered 2 mm away from the radiation source). Patients were enrolled in the Washington Radiation for In-Stent Restenosis Trial (WRIST; ISR length, 10 to 47 mm; n=36) or Long WRIST (ISR length, 36 to 80 mm; n=30). External elastic membrane, stent, lumen, and intimal hyperplasia (IH; stent minus lumen) areas and source-to-target (intravascular ultrasound catheter to external elastic membrane) distances were measured. Postintervention stent areas were larger in WRIST and smaller in Long WRIST patients (P:<0.0001). At follow-up, maximum IH area significantly increased in both WRIST and Long WRIST patients (P:<0.0001 for both), but this increase was greater in Long WRIST patients (P:=0.0006). Similarly, minimum lumen cross-sectional area significantly decreased in both WRIST and Long WRIST patients (P:<0.05 and P:<0.0001, respectively), but this decrease was more pronounced in Long WRIST patients (P:=0.0567). The maximum source-to-target distance was longer in Long WRIST than in WRIST, and it correlated directly with ISR length (r=0.547, P:<0.0001). Overall, the change in minimum lumen area and the change in maximum IH area correlated with the maximum source-to-target distance (r=0.352, P:=0.0038 and r=0.523, P:<0.0001 for WRIST and Long WRIST, respectively). The variability (maximum/minimum) in IH area at follow-up also correlated with the maximum source-to-target distance (r=0.378, P:<0.0001). CONCLUSIONS: Brachytherapy may be less effective in longer ISR lesions because of the greater variability and longer source-to-target distances in diffuse ISR.

Brachytherapy↗

Yttrium-90 delivered via a centering catheter and afterloader, given both before and after stent implantation, inhibits neointima formation in porcine coronary arteries.

Background: Intracoronary radiation (IR) studies have shown reduction of neointima formation (NF). Extrapolation of animal studies with beta-radiation to clinical trials have shown variable results, which may be related to dosimetry, centering issues, and/or shielding of beta-rays by the stent metal. We examined the effect of yttrium-90 (90Y), a pure beta-emitter delivered via an automatic afterloader to a centering catheter, on the inhibition of NF in balloon-injured (BI) porcine coronary arteries as well as in arteries receiving 90Y either prior to or following stent implantation (SI).Methods: Twenty-three swine (44 coronary arteries) were studied. In the first study, IR (18 Gy at 1.2 mm from the balloon surface) was administered in 17 arteries following BI, while eight control arteries were subjected to BI only. In the second study, 10 swine (19 coronary arteries) underwent SI. IR (18 Gy) was administered in six arteries before and in eight arteries after SI, while five control arteries received SI only. The animals were sacrificed 2 weeks after BI and 4 weeks after SI. Their coronaries were perfusion fixed and stained, and vessel parameters (intimal area [IA] and medial fracture length [FL]) were analyzed by computer-aided histomorphometry.Results: Arteries subjected to IR following BI had less NF compared to controls (IA/FL=0.14+/-0.2 mm vs. 0.49+/-0.2 mm; P=0.003). IA was reduced significantly in the arteries receiving radiation before and after SI compared to controls (0.92+/-0.98 and 0.00+/-0/00 vs. 2.72+/-1.2 mm(2); P=0.014), despite similar SI in all groups.Conclusions: IR with 90Y delivered via a centering catheter is safe and effective with complete and homogenous inhibition of NF in the context of BI or SI in the porcine coronary model.

Journal Article↗

Acute renal failure requiring dialysis after percutaneous coronary interventions.

Acute renal failure requiring dialysis is a rare but serious complication after percutaneous coronary interventions (PCI), associated with high in-hospital mortality and poor long-term survival. We have analyzed the incidence, resource utilization, short- and long-term outcomes, and predictors of dialysis after percutaneous coronary interventions. We studied 51 consecutive patients who were not on dialysis on admission and developed acute renal failure that required in-hospital dialysis after PCI in comparison to the 7,690 patients who did not require dialysis after PCI. Patients who required dialysis were older, with a higher incidence of hypertension, diabetes, prior bypass surgery, chronic renal failure, and a significantly lower left ventricular ejection fraction. Despite similar angiographic success, these patients had a higher incidence of in-hospital mortality (27.5% vs. 1.0%, P < 0.0001), non-Q-wave myocardial infarction (45.7% vs. 14.6%, P < 0.0001), vascular and bleeding complications, and longer hospitalization. At 1-year follow-up, mortality (54.5% vs. 6.4%, P < 0.0001), myocardial infarction (4.5% vs. 1.6%, P = 0.006), and event-free survival (38.6% vs. 72.0%, P < 0.0001) were significantly worse in patients who required dialysis compared to patients who did not. Multivariate analysis revealed in-hospital dialysis and an increase in baseline serum creatinine levels as the most important predictors of in-hospital and long-term mortality. Thus, acute renal failure that requires dialysis after percutaneous coronary interventions is associated with very high in-hospital and 1-year mortality rates and a dramatic increase in hospital resource utilization.

Acute Kidney Injury↗

Clinical outcomes of compromised side branch (stent jail) after coronary stenting with the NIR stent.

Acute side-branch (SB) compromise or occlusion stent jail after native coronary stenting is a matter of concern. Attempts at maintaining SB patency can be a technical challenge. The purpose of this study was to determine the clinical impact of SB compromise or occlusion in patients undergoing stenting of parent vessel lesions. We evaluated in-hospital and long-term clinical outcomes (death, Q-wave myocardial infarction, and repeat revascularization rates at 6 months) in 318 consecutive patients undergoing NIR stent implantation across an SB. Based on independent angiographic analysis, 218 (68.6%) patients had no poststent SB compromise, 85 (26.7%) patients had narrowed SB (> 70% narrowing, without total occlusion), and 15 (4.7%) patients had an occluded SB after stent implantation. The baseline patient and lesion characteristics were similar between the groups. Procedural success was 100%. Patients with SB occlusion had a higher stents/lesion ratio (P < 0.006). Side-branch occlusion was associated with higher in-hospital ischemic complications (Q-wave myocardial infarction, 7%; non-Q-wave myocardial infarction, 20%; P < 0.05) compared to patients with SB compromise or normal SB. At 6-month follow-up, there was a trend for more myocardial infarctions in the group with SB occlusion during the index procedure (Q-wave myocardial infarction, 7% vs. 1% in the narrowed and 0% in normal SB; P = 0.09). However, late target lesion revascularization and mortality were similar in the three groups (P = 0.91). SB occlusion after parent vessel stenting is associated with more frequent in-hospital Q-wave and non-Q-wave myocardial infarctions. However, with the NIR stent, side-branch compromise or occlusion does not influence late (6 month) major adverse events, including death, myocardial infarction, or need for repeat revascularization.

Aged↗

The effect of intracoronary radiation for the treatment of recurrent in-stent restenosis in patients with chronic renal failure.

OBJECTIVES: This study was designed to analyze the in-hospital and six-month clinical and angiographic outcomes of patients with chronic renal failure (CRF) treated with intracoronary radiation for the prevention of recurrence of in-stent restenosis. BACKGROUND: Patients with CRF are at a higher risk than the general population for accelerated atherosclerotic cardiovascular disease and for restenosis after percutaneous coronary intervention. Previous studies have shown the effectiveness of both beta and gamma radiation in preventing recurrent restenosis in patients with in-stent restenosis. METHODS: We studied the in-hospital and six-month clinical and angiographic outcomes of 118 patients with CRF and 481 consecutive patients without CRF who were treated with intracoronary radiation for the prevention of recurrence of in-stent restenosis in native coronaries and saphenous vein grafts. RESULTS: Patients with CRF were usually older, women, hypertensive and diabetic, with multivessel disease and with reduced left ventricular function. In-hospital outcome for patients with CRF was marred by a higher incidence of death, non-Q-wave myocardial infarction and major vascular and bleeding complications. At six-month follow-up, the mortality rate was higher in patients with CRF, 7.6% compared with 1.9% in non-CRF patients (p = 0.003). Restenosis, target lesion revascularization (TLR) and target vessel revascularization (TVR) rates were similar in the two groups. In patients with CRF, radiation therapy compared to placebo reduced restenosis (53.8% vs. 22.6%, p = 0.04), TLR (71.4% vs. 15.3%, p < 0.0001) and TVR (78.6% vs. 23.7%, p = 0.0002). CONCLUSIONS: Intracoronary radiation for the prevention of recurrence of in-stent restenosis achieved similar rates of restenosis and revascularization procedures in patients with and without CRF. Despite this benefit, patients with renal dysfunction continued to have significantly higher in-hospital and six-month adverse outcomes.

Aged↗

Intravascular radiation therapy after balloon angioplasty of narrowed femoropopliteal arteries to prevent restenosis: results of the PARIS feasibility clinical trial.

PURPOSE: To conduct a feasibility study to assess the feasibility, safety, and outcome of endoluminal gamma radiation therapy after balloon angioplasty of superficial femoral artery (SFA) lesions. MATERIALS AND METHODS: Forty patients with claudication were enrolled in the study and underwent percutaneous transluminal angioplasty (PTA) of SFA lesions with a mean lesion length of 9.8 cm +/- 3.0 and a mean reference vessel diameter of 5.2 mm +/- 3.1. After successful PTA, a segmented centering balloon catheter was positioned to cover the PTA site. The patients were then transported to the radiation oncology suite and treated with a microSelectron HDR afterloader with use of an Ir-192 source with a prescribed dose of 14 Gy, 2 mm into the vessel wall. Ankle-brachial index (ABI) and Rutherford score were evaluated at 1, 6, and 12 months after the procedure and angiographic follow-up was conducted at 6 months. RESULTS: Radiation was delivered successfully to 35 of 40 patients. There were no procedural complications. Exercise and rest ABI were higher at 1 year (0.72 +/- 0.26 and 0.89 +/- 0.18, respectively) compared to baseline (0.51 +/- 0.25 and 0.67 +/- 0.17, respectively). Maximum walking time on a treadmill increased from 3.41 min +/- 2.41 to 4.43 min +/- 2.49 at 30 days and was 4.04 min +/- 2.8 at 12 months. The angiographic binary restenosis rate at 6 months was 17.2% and the clinical restenosis rate at 12 months was 13.3%. There were no angiographic or clinical adverse events related to the radiation therapy. CONCLUSIONS: Intraarterial radiation after PTA of SFA lesions with use of high-dose rate gamma radiation is feasible and safe. The angiographic and clinical improvements are sustainable at 1 year and represent a potent antirestenotic therapy for the treatment of narrowed peripheral arteries.

Adult↗