Treatment of focal in-stent restenosis with balloon angioplasty alone versus stenting: Short- and long-term results.

BACKGROUND: Although both percutaneous transluminal coronary angioplasty (PTCA) and additional stenting can be used for the treatment for focal in-stent restenosis (ISR), no large-scale comparative data on the clinical outcomes after these interventional procedures have been reported. METHODS: In the current study we compared the in-hospital and long-term clinical results of PTCA alone (n = 266 patients, n = 364 lesions) versus stenting (n = 135 patients, n = 161 lesions) for the treatment of focal ISR, defined as a lesion length less than or equal to 10 mm. RESULTS: There were significantly more diabetic patients in the PTCA group than in the stent group (36% vs 26%, P =.04), but other baseline characteristics were similar. Lesion length and preprocedure minimal lumen diameter (MLD) were also similar in the two groups, but the stent group had a larger reference vessel diameter (3.40 +/- 0.73 mm vs 2.99 +/- 0.68 mm, P <.001). Stenting achieved a larger postprocedure MLD than PTCA did (2.95 +/- 0.95 mm vs 2.23 +/- 0.60 mm, P <.001) and a smaller residual diameter stenosis (11% +/- 15% vs 23% +/- 16%, P =.04). Angiographic success was achieved in all cases. The rate of death/Q-wave infarction of urgent revascularization was higher with PTCA than with stent (5.6% vs 0.7%, P =.02). Postprocedure creatine kinase myocardial band enzyme elevation >5 times normal was more frequent with stent (18.5% vs 9.7%, P =.05). At 1 year the two interventional strategies had similar cumulative mortality (4.6% PTCA vs 5.1% stent, P not significant) and target lesion revascularization rate (24.6% PTCA vs 26.5% stent, P not significant). By multivariate analysis, the sole predictor of target lesion revascularization was diabetes (odds ratio 2.4, 95% confidence intervals 1.2-4.7, P =.01). CONCLUSION: Repeat stenting for the treatment of focal ISR had a higher postprocedure creatine kinase myocardial band elevation rate and similar long-term clinical results compared with PTCA alone.

Aged↗

A novel 32P deployable balloon system inhibits formation of neointima in porcine coronary arteries after balloon-overstretching injury.

BACKGROUND: Intracoronary radiation has shown the potential to reduce formation of neointima in porcine models of restenosis. OBJECTIVE: To investigate the feasibility, safety, and efficacy of a new 'deployable-balloon' device with radioisotope 32P integrated into the balloon material. METHODS: Ten swine were subjected to balloon-overstretching injury in 20 coronary arteries and were randomly allocated to receive a radiation dose of 0, 15, or 20Gy prescribed to 1 mm from the surface of the radioactive balloon material. The animals were killed 4 weeks after the procedure. Their coronaries were perfusion fixed and stained. Vessel parameters (area of intima and length of fracture) and area of thrombus area were analyzed by computer-aided histomorphometry. RESULTS: Radiation treatment with the new 32P balloon device was performed without complications. The lengts of fracture for the three groups were similar (NS). Formation of neointima after balloon injury was less in members of the radiated groups than it was in controls (area of intima/length of fracture was 0.70 +/-0.12 mm for controls, 0.08+/-0.13mm with 15 Gy, and 0.07+/-0.17 mm with 20 Gy; P < 0.001). Vessels treated with 20 Gy had a greater total area of thrombus (0.00+/-0.00 versus 0.51+/-0.98 mm2, P< 0.01). CONCLUSIONS: Intracoronary radiation therapy using a new 32P deployable-balloon system is feasible and safe. A radiation dose of 15 Gy was sufficient to inhibit neointimal response in the porcine coronary-balloon-injury model.

Angioplasty, Balloon, Coronary↗

Intracoronary beta radiation: state of the art.

This state-of-the-art review is intended to explore the development of beta radiation including catheter delivered and permanent implants from its inception to current practice. Specific focus will be given to the isotopes currently available, radiation physics of beta emitters, preclinical studies, clinical trials, beta radiation delivery systems, and implications for future practice. The encouraging results from the clinical trials have established vascular brachytherapy as a standard of care for patients with in-stent restenosis. Vascular brachytherapy requires additional "fine-tuning" to achieve full optimization.

Beta Particles↗

Intravascular radiation for the prevention of recurrence of restenosis in coronary arteries.

Despite the use of new technology and adjunctive pharmacological therapy, in-stent restenosis continues to hamper the outcome of approximately 150,000 patients who undergo stented coronary angioplasty in the US annually. While coronary stenting eliminates elastic recoil and vessel contracture by acting as a mechanical scaffold within the vessel, it is unable to inhibit excessive neointimal formation and may actually promote it. For years, the growth-inhibiting properties of ionising radiation have been used successfully to control benign proliferative disorders. Based on this experience, vascular brachytherapy, the intravascular delivery of radiation, was viewed as a viable solution to inhibit neointimal hyperplasia. A series of studies performed in animal models identified the mechanisms by which radiation may reduce restenosis. Data from these studies showed that endovascular radiation reduces restenosis by inhibiting cell proliferation and by inducing favourable remodelling. The success of these initial studies led to several double-blind, multicentre, placebo-controlled, randomised, clinical trials evaluating intravascular radiation, with either gamma- or beta-radiation sources, proved to be an effective solution for the prevention of neointimal proliferation and restenosis. However, an increased rate of late thrombosis in patients who had received intracoronary radiation did evolve from the initial use of this therapy. Prolonged antiplatelet therapy and a reduction in the number of new stents placed at the time of radiation has been shown to minimise these complications. Other concerns that still need to be resolved include edge effect and geographical miss. Intravascular brachytherapy is currently the only approved therapy for this complex disease. It is clear that there are still on-going concerns that will eventually be clarified when the long-term results from ongoing clinical trials around the world become available.

Brachytherapy↗

Effect of intracoronary gamma-radiation therapy on in-stent restenosis: An intravascular ultrasound analysis from the gamma-1 study.

BACKGROUND: The aim of this study was to use serial volumetric intravascular ultrasound to evaluate the effect of gamma-radiation on recurrent in-stent restenosis. METHODS AND RESULTS: After successful reintervention, patients were randomized to receive either (192)Ir or placebo. Intravascular ultrasound studies with motorized pullback (0.5 mm/s) were performed immediately after irradiation and at 8-month follow-up in 70 patients. Paired volumetric analysis of the stented segment and of 5-mm proximal and distal reference segments was performed; this included measurements of the external elastic membrane, lumen, plaque and media (external elastic membrane minus lumen), stent, and intimal hyperplasia (stent minus lumen). Baseline proximal reference, stent, and distal reference measurements were similar in both groups. The changes in proximal and distal reference measurements of the external elastic membrane, plaque and media, and lumen areas were similar in both groups. However, the decrease in stented segment lumen volume was less in the (192)Ir patients than the placebo patients (-25+/-34 mm(3) versus -48+/-42 mm(3); P:=0.0225), and the increase in the volume of intimal hyperplasia in the stented segment was less in the (192)Ir patients than in the placebo patients (28+/-37 mm(3) versus 50+/-40 mm(3); P:=0.0352). When averaged over the length of the stented segment (32+/-13 mm versus 33+/-14 mm; P:=0.9), the increase in mean area of intimal hyperplasia was 0.8+/-1.0 mm(2) in the (192)Ir group and 1.6+/-1.2 mm(2) in the control group (P:=0.0065). Late stent-vessel wall malapposition was noted in one placebo patient and no (192)Ir patients. CONCLUSIONS: gamma-Radiation therapy can effectively prevent recurrent in-stent restenosis by inhibiting neointimal formation within the stent. At the stent edge, there were no significant differences between (192)Ir and placebo patients.

Analysis of Variance↗

S-nitrosoglutathione reduces nonocclusive thrombosis rate following balloon overstretch injury and intracoronary irradiation of porcine coronary arteries.

PURPOSE: Intracoronary radiation (IR) suppresses neointima formation following balloon injury in animal models. High doses of radiation exacerbate thrombosis and delay re-endothelialization. The free radical nitric oxide (NO) has been reported to inhibit platelet aggregation, reduce neointimal hyperplasia, and stimulate re-endothelialization. This study examined the effects of a chemical NO donor on neointima formation, thrombosis, and healing of irradiated porcine coronary arteries. METHODS AND MATERIALS: Vascular lesions were created in the coronary arteries of 59 domestic swine by overstretch balloon injury. Arteries were then left untreated or were treated with intracoronary gamma-radiation using Iridium-192 in each artery to deliver 5 or 15 Gy at 2 mm from the center of the source. The chemical NO donor S-nitrosoglutathione (GSNO) was infused i.v. at a rate of 250 microg/min for 10 min before injury, followed by a continuous infusion for 60 min. Animals were euthanized at 14 days and their arteries were analyzed for histomorphometric indices of proliferation and thrombosis. RESULTS: A dose of 15 Gy reduced the ratio of intimal area to medial fracture length (IA/FL) versus control (0.06 +/- 0.05 0.54 +/- 0.10 [p < 0. 001]) but increased the nonocclusive thrombosis rate compared to controls (85% vs. 30%; p < 0.05). A low dose of 5 Gy did not affect neointima formation. Treatment with GSNO reduced thrombosis in all treated groups: control, 15%; 5 Gy, 18%; and 15 Gy, 35% (p < 0.05) without affecting neointima formation. CONCLUSION: Systemic administration of GSNO during balloon injury and IR was tolerated well by the swine and resulted in reduction of the thrombosis rate, especially at high doses, without apparent effect on neointima formation.

Animals↗

Incidence, management, and outcome of coronary artery perforation during percutaneous coronary intervention.

We have analyzed the incidence, management, and outcome of 84 cases of coronary artery perforation in patients who underwent percutaneous coronary intervention at our institution. This complication was more frequent in female patients and in patients who underwent lesion modification with atheroablative devices. A total of 8 patients (9.5%) died after the procedure. They were usually older and had a higher incidence of cardiac tamponade; a larger percentage of these patients underwent emergency surgery than those who survived.

Adult↗

Anti-restenotic effect of copper-62 liquid-filled balloon in porcine coronary arteries: novel use of a short half-life positron emitter.

PURPOSE: To determine the efficacy of the use of copper-62, a positron emitter with a half-life of 9.7 minutes, as an intracoronary brachytherapy (IRBT) source in the prevention of neointima formation (NF) following overstretch balloon injury (BI) in the porcine model. METHODS AND MATERIALS: Sixteen swine were treated after BI to their left anterior descending (LAD), left circumflex (LCX), and/or right coronary artery (RCA). Twelve of the injured arteries received placebo and 10 received 25 Gy, delivered to 0.5 mm from the surface of the treatment balloon filled with liquid (62)Cu. Dosimetry was based on Monte Carlo calculations. Two weeks after treatment, the animals were sacrificed, and the treated coronaries were perfusion-fixed and stained. Intimal area (IA) and medial fracture length (FL) were analyzed by computer-aided histomorphometry. RESULTS: The ((62)Zn/(62)Cu) generator, together with a rapid concentration process, was successful in delivering the short-lived (62)Cu at the high concentration required for intravascular brachytherapy (IVBT). The fracture length in the two groups was similar (2.10 +/- 0.57; 2.02 +/- 0.77; p = NS). Arteries studied showed significant reduction in NF (IA: 0.23 +/- 0.47 mm(2) vs. 1.08 +/- 0.57 mm(2); p < 0.01. IA/FL = 0.09 +/- 0.17 mm vs. 0.51 +/- 0.21 mm; p < 0.01). CONCLUSIONS: This study demonstrated that use of liquid (62)Cu as an IVBT source is safe and feasible. All 16 swine tolerated the treatment well with no radiation-induced side effects or symptoms throughout the 2-week period. The isotope delivered the dose necessary to inhibit NF in the porcine coronary BI model.

Animals↗

Inhibition of restenosis with beta-emitting radiotherapy: Report of the Proliferation Reduction with Vascular Energy Trial (PREVENT).

BACKGROUND: Intracoronary gamma- and beta-radiation have reduced restenosis in animal models. In the clinical setting, the effectiveness of beta-emitters has not been studied in a broad spectrum of patients, particularly those receiving stents. METHODS AND RESULTS: A prospective, randomized, sham-controlled study of intracoronary radiotherapy with the beta-emitting (32)P source wire, using a centering catheter and automated source delivery unit, was conducted. A total of 105 patients with de novo (70%) or restenotic (30%) lesions who were treated by stenting (61%) or balloon angioplasty (39%) received 0 (control), 16, 20, or 24 Gy to a depth of 1 mm in the artery wall. Angiography at 6 months showed a target site late loss index of 11+/-36% in radiotherapy patients versus 55+/-30% in controls (P:<0.0001). A low late loss index was seen in stented and balloon-treated patients and was similar across the 16, 20, and 24 Gy radiotherapy groups. Restenosis (>/=50%) rates were significantly lower in radiotherapy patients at the target site (8% versus 39%; P:=0.012) and at target site plus adjacent segments (22% versus 50%; P:=0.018). Target lesion revascularization was needed in 5 radiotherapy patients (6%) and 6 controls (24%; P:<0.05). Stenosis adjacent to the target site and late thrombotic events reduced the overall clinical benefit of radiotherapy. CONCLUSIONS: beta-radiotherapy with a centered (32)P source is safe and highly effective in inhibiting restenosis at the target site after stent or balloon angioplasty. However, minimizing edge narrowing and late thrombotic events must be accomplished to maximize the clinical benefit of this modality.

Angioplasty, Balloon, Coronary↗

Treatment of in-stent restenosis with excimer laser coronary angioplasty versus rotational atherectomy: comparative mechanisms and results.

BACKGROUND: Atheroablation yields improved clinical results for balloon angioplasty (percutaneous transluminal coronary angioplasty, PTCA) in the treatment of diffuse in-stent restenosis (ISR). METHODS AND RESULTS: We compared the mechanisms and clinical results of excimer laser coronary angioplasty (ELCA) versus rotational atherectomy (RA), both followed by adjunct PTCA; 119 patients (158 ISR lesions) were treated with ELCA+PTCA and 130 patients (161 ISR lesions) were treated with RA+PTCA. Quantitative coronary angiographic and planar intravascular ultrasound (IVUS) measurements were performed routinely. In addition, volumetric IVUS analysis to compare the mechanisms of lumen enlargement was performed in 28 patients with 30 lesions (16 ELCA+PTCA, 14 RA+PTCA). There were no significant between-group differences in preintervention or final postintervention quantitative coronary angiographic or planar IVUS measurements of luminal dimensions. Angiographic success and major in-hospital complications with the 2 techniques were also similar. Volumetric IVUS analysis showed significantly greater reduction in intimal hyperplasia volume after RA than after ELCA (43+/-14 versus 19+/-10 mm(3), P<0.001) because of a significantly higher ablation efficiency (90+/-10% versus 76+/-12%, P = 0.004). However, both interventional strategies had similar long-term clinical outcome; 1-year target lesion revascularization rate was 26% with ELCA+PTCA versus 28% with RA+PTCA (P = NS). CONCLUSIONS: Despite certain differences in the mechanisms of lumen enlargement, both ELCA+PTCA and RA+PTCA can be used to treat diffuse ISR with similar clinical results.

Angioplasty, Balloon, Coronary↗

Safety of intracoronary gamma-radiation on uninjured reference segments during the first 6 months after treatment of in-stent restenosis: a serial intravascular ultrasound study.

BACKGROUND: The effects of endovascular irradiation on uninjured reference segments during the treatment of in-stent restenosis are unknown. METHODS AND RESULTS: In the Washington Radiation for In-Stent restenosis Trial (WRIST), patients with in-stent restenosis were first treated with conventional catheter-based techniques and then randomized (blinded) to receive either gamma-irradiation ((192)Ir) or a placebo (dummy seeds). We identified all patients in whom the active (n=19) or dummy seeds (n=19) extended >10 mm proximal and distal to the in-stent restenosis lesion. Serial (postirradiation and follow-up) external elastic membrane (EEM), lumen, and plaque and media (EEM-lumen) areas were measured (using intravascular ultrasound) every 1 mm over 5-mm-long reference segments that were 6 to 10 mm proximal and distal to the in-stent restenosis lesion. During follow-up, a similar small increase occurred in the plaque and media area in the proximal and distal reference segments in both (192)Ir and placebo patients. However, in the (192)Ir patients, an increase in both proximal and distal EEM area occurred; as a result, no change in lumen area occurred. Conversely, in the placebo patients, the proximal reference EEM area decreased, and no change occurred in the distal reference EEM area; this contributed to a decrease in lumen area. CONCLUSIONS: There was no evidence of a deleterious effect of gamma-irradiation on angiographically normal uninjured reference segments in the first 6 months after the treatment of in-stent restenosis.

Coronary Disease↗

Intracoronary gamma-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis.

BACKGROUND: Treatment of in-stent restenosis presents a critical limitation of intracoronary stent implantation. Ionizing radiation has been shown to decrease neointimal formation within stents in animal models and in initial clinical trials. We studied the effects of intracoronary gamma-radiation therapy versus placebo on the clinical and angiographic outcomes of patients with in-stent restenosis. METHODS AND RESULTS: One hundred thirty patients with in-stent restenosis underwent successful coronary intervention and were then blindly randomized to receive either intracoronary gamma-radiation with (192)Ir (15 Gy) or placebo. Four independent core laboratories blinded to the treatment protocol analyzed the angiographic and intravascular ultrasound end points of restenosis. Procedural success and in-hospital and 30-day complications were similar among the groups. At 6 months, patients assigned to radiation therapy required less target lesion revascularization and target vessel revascularization (9 [13.8%] and 17 [26.2%], respectively) compared with patients assigned to placebo (41 [63.1%, P=0.0001] and 44 [67.7%, P=0.0001], respectively). Binary angiographic restenosis was lower in the irradiated group (19% versus 58% for placebo, P=0.001). Freedom from major cardiac events was lower in the radiation group (29.2% versus 67.7% for placebo, P<0.001). CONCLUSIONS: Intracoronary gamma-radiation used as adjunct therapy for patients with in-stent restenosis significantly reduces both angiographic and clinical restenosis.

Aged↗

Intracoronary beta-radiation therapy inhibits recurrence of in-stent restenosis.

BACKGROUND: Intracoronary gamma-radiation therapy reduces recurrent in-stent restenosis (ISR). This study, BETA WRIST (Washington Radiation for In-Stent restenosis Trial) was designed to examine the efficacy and safety of the beta-emitter 90-yttrium for the prevention of recurrent ISR. METHODS AND RESULTS: A total of 50 consecutive patients with ISR in native coronaries underwent percutaneous transluminal coronary angioplasty, laser angioplasty, rotational atherectomy, and/or stent implantation. Afterward, a segmented balloon catheter was positioned and automatically loaded with a 90-yttrium, 0.014-inch source wire that was 29 mm in length to deliver a dose of 20.6 Gy at 1.0 mm from the balloon surface. In 17 patients, manual stepping of the radiation catheter was necessary for lesions >25 mm in length. The radiation was delivered successfully to all patients, with a mean dwell time of 3.0+/-0.4 minutes. Fractionation of the dose due to ischemia was required in 11 patients. At 6 months, the binary angiographic restenosis rate was 22%, the target lesion revascularization rate was 26%, and the target vessel revascularization rate was 34%; all rates were significantly lower than those of the placebo group of gamma-WRIST. CONCLUSIONS: beta-Radiation with a 90-yttrium source used as adjunct therapy for patients with ISR results in a lower-than-expected rate of angiographic and clinical restenosis.

Adult↗

Percutaneous revascularization of the internal mammary artery graft: short- and long-term outcomes.

OBJECTIVES: We evaluated the short- and long-term clinical outcomes after percutaneous revascularization of the internal mammary artery (IMA) graft. BACKGROUND: Previous reports in a relatively small number of patients have indicated the safety of balloon angioplasty for the treatment of stenoses in the IMA graft. However, the use of alternative interventional techniques and their long-term results have not yet been evaluated. METHODS: We analyzed the in-hospital and one-year clinical outcomes of 174 consecutive patients who underwent percutaneous revascularization of 202 lesions located in the IMA graft, by either balloon angioplasty or stenting. RESULTS: Anastomotic lesions were evident in 128 cases (63%), and they were more commonly treated with balloon angioplasty (116/128, 91%), whereas lesions located at the ostium (n = 16, 8%) were more frequently treated with stents (11/16, 69%). Procedural success was 97% with excellent in-hospital outcome: 0.6% mortality rate, no Q-wave myocardial infarction (MI) and 0.6% rate of urgent bypass surgery. Cumulative one-year rates were: mortality 4.4%, MI 2.9% and target lesion revascularization (TLR) 7.4%. CONCLUSIONS: Revascularization of the IMA graft can be performed safely, with high procedural success and a low rate of in-hospital complications. Long-term follow-up showed very low TLR rate.

Adult↗

Serial volumetric intravascular ultrasound analysis of the efficacy of beta irradiation in preventing recurrent in-stent restenosis.

We compared postintervention and follow-up intravascular ultrasound findings of 25 patients from the beta-Washington Radiation for InStent restenosis Trial (in which all patients received radiation) and 75 patients from the Washington Radiation for InStent restenosis Trial (in which patients were randomized to gamma irradiation). The decrease in lumen volume was similar for beta versus gamma and less in both gamma versus placebo and beta versus placebo; the increase in intimal hyperplasia volume was similar for beta versus gamma and greater in both beta versus placebo and gamma versus placebo.

Beta Particles↗